메뉴 건너뛰기




Volumn 21, Issue 7, 2005, Pages 815-819

Influence of thread design on bioabsorbable interference screw insertion torque during retrograde fixation of a soft-tissue graft in synthetic bone

Author keywords

Anterior cruciate ligament reconstruction; Biomechanical testing; Bone mineral density; Retrograde fixation

Indexed keywords

ALLOGRAFT; ARTICLE; BIODEGRADABLE IMPLANT; BIOMECHANICS; BONE GRAFT; BONE SCREW; COMPARATIVE STUDY; GRAFT FAILURE; IMPLANTATION; INTERMETHOD COMPARISON; PROSTHESIS FAILURE; RIGIDITY; TIBIALIS ANTERIOR MUSCLE; TISSUE GRAFT; TORQUE; WEIGHT BEARING;

EID: 22144441635     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2005.04.108     Document Type: Article
Times cited : (7)

References (27)
  • 1
    • 0027254805 scopus 로고
    • Quantitative evaluation after arthroscopic anterior cruciate ligament reconstruction. Allograft versus autograft
    • K. Shino, K. Nakata, S. Horibe, M. Inoue, S. Nakagawa Quantitative evaluation after arthroscopic anterior cruciate ligament reconstruction. Allograft versus autograft Am J Sports Med 21 1993 609 616
    • (1993) Am J Sports Med , vol.21 , pp. 609-616
    • Shino, K.1    Nakata, K.2    Horibe, S.3    Inoue, M.4    Nakagawa, S.5
  • 2
    • 0036635244 scopus 로고    scopus 로고
    • A biomechanical evaluation of anterior and posterior tibialis tendons as suitable single-loop anterior cruciate ligament grafts
    • T.L. Haut Donahue, S.M. Howell, M.L. Hull, C. Gregersen A biomechanical evaluation of anterior and posterior tibialis tendons as suitable single-loop anterior cruciate ligament grafts Arthroscopy 18 2002 589 597
    • (2002) Arthroscopy , vol.18 , pp. 589-597
    • Haut Donahue, T.L.1    Howell, S.M.2    Hull, M.L.3    Gregersen, C.4
  • 4
    • 0034820029 scopus 로고    scopus 로고
    • Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel
    • J.B. Selby, D.L. Johnson, P. Hester, D.N. Caborn Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel Am J Sports Med 29 2001 614 619
    • (2001) Am J Sports Med , vol.29 , pp. 614-619
    • Selby, J.B.1    Johnson, D.L.2    Hester, P.3    Caborn, D.N.4
  • 5
    • 0036461427 scopus 로고    scopus 로고
    • Allograft anterior tibialis tendon with bioabsorbable interference screw fixation in anterior cruciate ligament reconstruction
    • D.N. Caborn, J.B. Selby Allograft anterior tibialis tendon with bioabsorbable interference screw fixation in anterior cruciate ligament reconstruction Arthroscopy 18 2002 102 105
    • (2002) Arthroscopy , vol.18 , pp. 102-105
    • Caborn, D.N.1    Selby, J.B.2
  • 6
    • 0033802701 scopus 로고    scopus 로고
    • Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque
    • J.C. Brand Jr, D. Pienkowski, E. Steenlage, D. Hamilton, D.L. Johnson, D.N. Caborn Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque Am J Sports Med 28 2000 705 710
    • (2000) Am J Sports Med , vol.28 , pp. 705-710
    • Brand Jr., J.C.1    Pienkowski, D.2    Steenlage, E.3    Hamilton, D.4    Johnson, D.L.5    Caborn, D.N.6
  • 7
    • 0029704294 scopus 로고    scopus 로고
    • Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: Influence of insertion torque, tunnel-bone block gap, and interference
    • G.A. Brown, F. Pena, T. Grontvedt, D. Labadie, L. Engebretsen Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees Influence of insertion torque, tunnel-bone block gap, and interference Knee Surg Sports Traumatol Arthrosc 3 1996 238 244
    • (1996) Knee Surg Sports Traumatol Arthrosc , vol.3 , pp. 238-244
    • Brown, G.A.1    Pena, F.2    Grontvedt, T.3    Labadie, D.4    Engebretsen, L.5
  • 8
    • 0033049022 scopus 로고    scopus 로고
    • Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstructions
    • D.A. McGuire, F.A. Barber, B.F. Elrod, B.F. Elrod, L.E. Paulos Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstructions Arthroscopy 15 1999 463 473
    • (1999) Arthroscopy , vol.15 , pp. 463-473
    • McGuire, D.A.1    Barber, F.A.2    Elrod, B.F.3    Elrod, B.F.4    Paulos, L.E.5
  • 9
    • 0035121512 scopus 로고    scopus 로고
    • Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation
    • D.G. Nagarkatti, B.P. McKeon, B.S. Donahue, J.P. Fulkerson Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation Am J Sports Med 29 2001 67 71
    • (2001) Am J Sports Med , vol.29 , pp. 67-71
    • Nagarkatti, D.G.1    McKeon, B.P.2    Donahue, B.S.3    Fulkerson, J.P.4
  • 10
    • 0034819478 scopus 로고    scopus 로고
    • Comparison of torsional strengths of bioabsorbable screws for anterior cruciate ligament reconstruction
    • J.J. Costi, A.J. Kelly, T.C. Hearn, D.K. Martin Comparison of torsional strengths of bioabsorbable screws for anterior cruciate ligament reconstruction Am J Sports Med 29 2001 575 580
    • (2001) Am J Sports Med , vol.29 , pp. 575-580
    • Costi, J.J.1    Kelly, A.J.2    Hearn, T.C.3    Martin, D.K.4
  • 13
    • 0017470703 scopus 로고    scopus 로고
    • The reversal of tissue differentiation around screws
    • H.K. Uhthoff, J. Germain The reversal of tissue differentiation around screws Clin Orthop 123 1997 248 252
    • (1997) Clin Orthop , vol.123 , pp. 248-252
    • Uhthoff, H.K.1    Germain, J.2
  • 14
    • 0015694102 scopus 로고
    • Mechanical factors influencing the holding power of screws in compact bone
    • H.K. Uhthoff Mechanical factors influencing the holding power of screws in compact bone J Bone Joint Surg Br 55 1973 633 639
    • (1973) J Bone Joint Surg Br , vol.55 , pp. 633-639
    • Uhthoff, H.K.1
  • 15
    • 53949098607 scopus 로고    scopus 로고
    • Anatomic tibial graft fixation using a retrograde bio-interference screw for endoscopic anterior cruciate ligament reconstruction
    • C.D. Morgan, D.A. Stein, E.H. Leitman, V.R. Kalman Anatomic tibial graft fixation using a retrograde bio-interference screw for endoscopic anterior cruciate ligament reconstruction Arthroscopy 18 2002 E38 (available online at www.arthroscopyjournal.org ).
    • (2002) Arthroscopy , vol.18 , pp. 38
    • Morgan, C.D.1    Stein, D.A.2    Leitman, E.H.3    Kalman, V.R.4
  • 16
    • 0028788134 scopus 로고
    • Isometry testing for anterior cruciate ligament reconstruction revisited
    • C.D. Morgan, V.H. Kalman, D. Grawl Isometry testing for anterior cruciate ligament reconstruction revisited Arthroscopy 11 1995 647 659
    • (1995) Arthroscopy , vol.11 , pp. 647-659
    • Morgan, C.D.1    Kalman, V.H.2    Grawl, D.3
  • 17
    • 0030912837 scopus 로고    scopus 로고
    • The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system
    • Y. Ishibashi, T. Rudy, G. Livesay, J.D. Stone, F.H. Fu, S.L. Woo The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability Evaluation using a robotic testing system Arthroscopy 13 1997 177 182
    • (1997) Arthroscopy , vol.13 , pp. 177-182
    • Ishibashi, Y.1    Rudy, T.2    Livesay, G.3    Stone, J.D.4    Fu, F.H.5    Woo, S.L.6
  • 18
    • 0036488211 scopus 로고    scopus 로고
    • Tendon healing in a bone tunnel. Part II: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep
    • A. Weiler, R.F.G. Hoffman, H.J. Bail, O. Rehm, N.P. Sudkamp Tendon healing in a bone tunnel. Part II: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep Arthroscopy 18 2002 124 135
    • (2002) Arthroscopy , vol.18 , pp. 124-135
    • Weiler, A.1    Hoffman, R.F.G.2    Bail, H.J.3    Rehm, O.4    Sudkamp, N.P.5
  • 19
    • 0034234702 scopus 로고    scopus 로고
    • Flipped patellar tendon autograft anterior cruciate ligament reconstruction
    • F.A. Barber Flipped patellar tendon autograft anterior cruciate ligament reconstruction Arthroscopy 16 2000 483 490
    • (2000) Arthroscopy , vol.16 , pp. 483-490
    • Barber, F.A.1
  • 20
    • 0036524466 scopus 로고    scopus 로고
    • Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading
    • S.U. Scheffler, N.P. Sudkamp, A. Gockenjan, R.F. Hoffmann, A. Weiler Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques The impact of fixation level and fixation method under cyclic loading Arthroscopy 18 2002 304 315
    • (2002) Arthroscopy , vol.18 , pp. 304-315
    • Scheffler, S.U.1    Sudkamp, N.P.2    Gockenjan, A.3    Hoffmann, R.F.4    Weiler, A.5
  • 21
    • 0032702339 scopus 로고    scopus 로고
    • Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws. Influence of screw length
    • D.M. Stadelmaier, W.R. Lowe, O.A. Ilahi, P.C. Noble, H.W. Kohl III Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws. Influence of screw length Am J Sports Med 27 1999 778 783
    • (1999) Am J Sports Med , vol.27 , pp. 778-783
    • Stadelmaier, D.M.1    Lowe, W.R.2    Ilahi, O.A.3    Noble, P.C.4    Kohl III, H.W.5
  • 23
    • 0031931882 scopus 로고    scopus 로고
    • Hamstring tendon fixation using interference screws: A biomechanical study in calf tibial bone
    • A. Weiler, R. Hoffmann, A.C. Stahelin, H.J. Bail, C.J. Siepe, N.P. Sudkamp Hamstring tendon fixation using interference screws A biomechanical study in calf tibial bone Arthroscopy 14 1998 29 37
    • (1998) Arthroscopy , vol.14 , pp. 29-37
    • Weiler, A.1    Hoffmann, R.2    Stahelin, A.C.3    Bail, H.J.4    Siepe, C.J.5    Sudkamp, N.P.6
  • 24
    • 0023975661 scopus 로고
    • Biologic fixation of ligament prostheses and augmentations: An evaluation of bone ingrowth in the dog
    • S.P. Arnoczky, P.A. Torzilli, R.F. Warren, A.A. Allen Biologic fixation of ligament prostheses and augmentations An evaluation of bone ingrowth in the dog Am J Sports Med 16 1988 106 112
    • (1988) Am J Sports Med , vol.16 , pp. 106-112
    • Arnoczky, S.P.1    Torzilli, P.A.2    Warren, R.F.3    Allen, A.A.4
  • 25
    • 0026473798 scopus 로고
    • Pullout strength of power- and hand-driven staples in synthetic bone: Effect of design parameters
    • K.K. Firoozbakhsh, M.S. Moneim, T.A. DeCoster Pullout strength of power- and hand-driven staples in synthetic bone Effect of design parameters J Orthop Trauma 6 1992 43 49
    • (1992) J Orthop Trauma , vol.6 , pp. 43-49
    • Firoozbakhsh, K.K.1    Moneim, M.S.2    Decoster, T.A.3
  • 26
    • 0028672891 scopus 로고
    • Evaluation of experimental and finite element models of synthetic and cadaveric femora for pre-clinical design-analysis
    • B.P. McNamara, L. Cristofolini, A. Toni, D. Taylor Evaluation of experimental and finite element models of synthetic and cadaveric femora for pre-clinical design-analysis Clin Materials 17 1994 131 140
    • (1994) Clin Materials , vol.17 , pp. 131-140
    • McNamara, B.P.1    Cristofolini, L.2    Toni, A.3    Taylor, D.4
  • 27
    • 0021337787 scopus 로고
    • Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions
    • F.R. Noyes, D.L. Butler, E.S. Grood, R.F. Zernicke, M.S. Hefzy Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions J Bone Joint Surg Am 66 1984 344 352
    • (1984) J Bone Joint Surg Am , vol.66 , pp. 344-352
    • Noyes, F.R.1    Butler, D.L.2    Grood, E.S.3    Zernicke, R.F.4    Hefzy, M.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.