메뉴 건너뛰기




Volumn 6, Issue 2, 2005, Pages 150-153

Pulmonary artery stenting without angiographic imaging

Author keywords

Atrial septal defect; Balloon; Stenosis; Stents; Tetralogy of Fallot

Indexed keywords

ARTICLE; BLOOD VESSEL TRANSPLANTATION; CASE REPORT; CHILD; FALLOT TETRALOGY; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; PULMONARY ARTERY; PULMONARY VALVE STENOSIS; RADIOGRAPHY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; STENOSIS, OCCLUSION AND OBSTRUCTION; STENT;

EID: 22044451054     PISSN: 1129471X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (15)
  • 1
    • 0025005250 scopus 로고
    • Juxtaductal pulmonary artery coarctation. An underestimated cause of branch pulmonary artery stenosis in patients with pulmonary atresia or stenosis and a ventricular septal defect
    • Elzenga NJ, van Suylen RV, Frohn-Mulder I, Essed CE, Bos E, Quaegebeur JM. Juxtaductal pulmonary artery coarctation. An underestimated cause of branch pulmonary artery stenosis in patients with pulmonary atresia or stenosis and a ventricular septal defect. J Thorac Cardiovasc Surg 1990; 100: 416-24.
    • (1990) J Thorac Cardiovasc Surg , vol.100 , pp. 416-424
    • Elzenga, N.J.1    van Suylen, R.V.2    Frohn-Mulder, I.3    Essed, C.E.4    Bos, E.5    Quaegebeur, J.M.6
  • 3
    • 0035281862 scopus 로고    scopus 로고
    • Balloon angioplasty for obstructed modified systemic-pulmonary artery shunts and pulmonary artery stenoses
    • Wang JK, Wu MH, Chang CI, Chiu IS, Lue HC. Balloon angioplasty for obstructed modified systemic-pulmonary artery shunts and pulmonary artery stenoses. J Am Coll Cardiol 2001; 37: 940-7.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 940-947
    • Wang, J.K.1    Wu, M.H.2    Chang, C.I.3    Chiu, I.S.4    Lue, H.C.5
  • 4
    • 0025309676 scopus 로고
    • Balloon angioplasty-branch pulmonary artery stenosis: Results from the Valvuloplasty and Angioplasty of Congenital Anomalies Registry
    • Kan JS, Marvin WJ Jr, Bass JL, Muster AJ, Murphy J. Balloon angioplasty-branch pulmonary artery stenosis: results from the Valvuloplasty and Angioplasty of Congenital Anomalies Registry. Am J Cardiol 1990; 65: 798-801.
    • (1990) Am J Cardiol , vol.65 , pp. 798-801
    • Kan, J.S.1    Marvin Jr, W.J.2    Bass, J.L.3    Muster, A.J.4    Murphy, J.5
  • 6
    • 0029093795 scopus 로고
    • Endovascular stents in the pulmonary circulation. Clinical impact on management and medium-term follow-up
    • Fogelman R, Nykanen D, Smallhorn JF, McCrindle BW, Freedom RM, Benson LN. Endovascular stents in the pulmonary circulation. Clinical impact on management and medium-term follow-up. Circulation 1995; 92: 881-5.
    • (1995) Circulation , vol.92 , pp. 881-885
    • Fogelman, R.1    Nykanen, D.2    Smallhorn, J.F.3    McCrindle, B.W.4    Freedom, R.M.5    Benson, L.N.6
  • 7
    • 0029862604 scopus 로고    scopus 로고
    • Stent implantation for relief of pulmonary artery stenosis: Immediate and short-term results
    • Hijazi ZM, al-Fadley F, Geggel RL, et al. Stent implantation for relief of pulmonary artery stenosis: immediate and short-term results. Cathet Cardiovasc Diagn 1996; 38: 16-23.
    • (1996) Cathet Cardiovasc Diagn , vol.38 , pp. 16-23
    • Hijazi, Z.M.1    al-Fadley, F.2    Geggel, R.L.3
  • 8
    • 0032032937 scopus 로고    scopus 로고
    • Intravascular stents in congenital heart disease: Short- and long-term results from a large single-center experience
    • Shaffer KM, Mullins CE, Grifka RG, et al. Intravascular stents in congenital heart disease: short- and long-term results from a large single-center experience. J Am Coll Cardiol 1998; 31: 661-7.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 661-667
    • Shaffer, K.M.1    Mullins, C.E.2    Grifka, R.G.3
  • 9
    • 0034114971 scopus 로고    scopus 로고
    • Treatment of pulmonary artery stenosis after arterial switch operation: Stent implantation vs balloon angioplasty
    • Formigari R, Santoro G, Guccione P, et al. Treatment of pulmonary artery stenosis after arterial switch operation: stent implantation vs balloon angioplasty. Catheter Cardiovasc Interv 2000; 50: 207-11.
    • (2000) Catheter Cardiovasc Interv , vol.50 , pp. 207-211
    • Formigari, R.1    Santoro, G.2    Guccione, P.3
  • 10
    • 0036260954 scopus 로고    scopus 로고
    • Interventional catheterization management of perioperative peripheral pulmonary stenosis: Balloon angioplasty or endovascular stenting
    • Rosales AM, Lock JE, Perry SB, Geggel RL. Interventional catheterization management of perioperative peripheral pulmonary stenosis: balloon angioplasty or endovascular stenting. Catheter Cardiovasc Interv 2002; 56: 272-7.
    • (2002) Catheter Cardiovasc Interv , vol.56 , pp. 272-277
    • Rosales, A.M.1    Lock, J.E.2    Perry, S.B.3    Geggel, R.L.4
  • 11
    • 0030663531 scopus 로고    scopus 로고
    • Magnetic resonance imaging compared with echocardiography in the evaluation of pulmonary artery abnormalities in children with tetralogy of Fallot following palliative and corrective surgery
    • Greenberg SB, Crisci KL, Koenig P, Robinson B, Anisman P, Russo P. Magnetic resonance imaging compared with echocardiography in the evaluation of pulmonary artery abnormalities in children with tetralogy of Fallot following palliative and corrective surgery. Pediatr Radiol 1997; 27: 932-5.
    • (1997) Pediatr Radiol , vol.27 , pp. 932-935
    • Greenberg, S.B.1    Crisci, K.L.2    Koenig, P.3    Robinson, B.4    Anisman, P.5    Russo, P.6
  • 12
    • 0026957756 scopus 로고
    • Magnetic resonance imaging: Evaluation of the Blalock-Taussig shunts and anatomy of the pulmonary artery
    • Ichida F, Hashimoto I, Miyazaki A, et al. Magnetic resonance imaging: evaluation of the Blalock-Taussig shunts and anatomy of the pulmonary artery. J Cardiol 1992; 22: 669-78.
    • (1992) J Cardiol , vol.22 , pp. 669-678
    • Ichida, F.1    Hashimoto, I.2    Miyazaki, A.3
  • 14
    • 0042967983 scopus 로고    scopus 로고
    • Balloon sizing of pulmonary branch stenosis: A useful method to guide stent implantation
    • Nagm AM, Moore JW. Balloon sizing of pulmonary branch stenosis: a useful method to guide stent implantation. J Invasive Cardiol 2003; 15: 437-8.
    • (2003) J Invasive Cardiol , vol.15 , pp. 437-438
    • Nagm, A.M.1    Moore, J.W.2
  • 15
    • 0030920254 scopus 로고    scopus 로고
    • Transballoon intravascular ultrasound imaging during balloon angioplasty in animal models with coarctation and branch pulmonary stenosis
    • Stock JH, Reller MD, Sharma S, Pavcnik D, Shiota T, Sahn DJ. Transballoon intravascular ultrasound imaging during balloon angioplasty in animal models with coarctation and branch pulmonary stenosis. Circulation 1997; 95: 2354-7.
    • (1997) Circulation , vol.95 , pp. 2354-2357
    • Stock, J.H.1    Reller, M.D.2    Sharma, S.3    Pavcnik, D.4    Shiota, T.5    Sahn, D.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.