메뉴 건너뛰기




Volumn 358, Issue 1-2, 2005, Pages 192-195

Falsely low LDL-cholesterol concentrations and artifactual undetectable HDL-cholesterol measured by direct methods in a patient with monoclonal paraprotein

Author keywords

Direct methods; HDL cholesterol; LDL cholesterol; Monoclonal paraprotein; Multiple myeloma

Indexed keywords

HIGH DENSITY LIPOPROTEIN CHOLESTEROL; LOW DENSITY LIPOPROTEIN CHOLESTEROL; PARAPROTEIN;

EID: 22044447084     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cccn.2005.02.008     Document Type: Article
Times cited : (21)

References (17)
  • 2
    • 0032535310 scopus 로고    scopus 로고
    • Long-term efficacy of low-density lipoprotein electrophoresis on coronary heart disease in familial hypercholesterolemia
    • H. Mabuchi, J. Koizumi, M. Shimizu, K. Kajinami, S. Miyamoto, and K. Ueda Long-term efficacy of low-density lipoprotein electrophoresis on coronary heart disease in familial hypercholesterolemia Am J Cardiol 82 1998 1489 1495
    • (1998) Am J Cardiol , vol.82 , pp. 1489-1495
    • Mabuchi, H.1    Koizumi, J.2    Shimizu, M.3    Kajinami, K.4    Miyamoto, S.5    Ueda, K.6
  • 4
    • 0024459485 scopus 로고
    • Comparison of ultracentrifugation and a precipitation method for high-density lipoprotein cholesterol quantitation in insulin-dependent diabetic patients
    • T. Jensen, S. Stender, and M. Deckert Comparison of ultracentrifugation and a precipitation method for high-density lipoprotein cholesterol quantitation in insulin-dependent diabetic patients Scand J Clin Lab Invest 49 1989 589 593
    • (1989) Scand J Clin Lab Invest , vol.49 , pp. 589-593
    • Jensen, T.1    Stender, S.2    Deckert, M.3
  • 5
    • 0034868731 scopus 로고    scopus 로고
    • Evolution of methods for measurement of HDL-cholesterol: From ultracentrifugation to homogeneous assays
    • G.R. Warnick, M. Nauck, and N. Rifai Evolution of methods for measurement of HDL-cholesterol: from ultracentrifugation to homogeneous assays Clin Chem 47 2001 1579 1596
    • (2001) Clin Chem , vol.47 , pp. 1579-1596
    • Warnick, G.R.1    Nauck, M.2    Rifai, N.3
  • 6
    • 0034116506 scopus 로고    scopus 로고
    • Falsely low direct HDL-cholesterol results in a patient with dysbetalipoproteinemia
    • W.L. Roberts, E.T. Leary, T.L. Lambert, L. Moulton, and J.L. Goestch Falsely low direct HDL-cholesterol results in a patient with dysbetalipoproteinemia Clin Chem 46 2000 560 562
    • (2000) Clin Chem , vol.46 , pp. 560-562
    • Roberts, W.L.1    Leary, E.T.2    Lambert, T.L.3    Moulton, L.4    Goestch, J.L.5
  • 7
    • 0033895535 scopus 로고    scopus 로고
    • Agreement study of methods based on the elimination principle for the measurement of LDL- and HDL-cholesterol compared with ultracentrifugation in patients with liver cirrhosis
    • F. Gomez, J. Camps, J.M. Simo, N. Ferre, and J. Joven Agreement study of methods based on the elimination principle for the measurement of LDL- and HDL-cholesterol compared with ultracentrifugation in patients with liver cirrhosis Clin Chem 46 2000 1188 1191
    • (2000) Clin Chem , vol.46 , pp. 1188-1191
    • Gomez, F.1    Camps, J.2    Simo, J.M.3    Ferre, N.4    Joven, J.5
  • 8
    • 0033810927 scopus 로고    scopus 로고
    • Evaluation of two different homogeneous assays for LDL-cholesterol in lipoprotein-X-positive serum
    • H. Fei, S. Maeda, H. Kirii, S. Fujigaki, N. Maekawa, and H. Fujii Evaluation of two different homogeneous assays for LDL-cholesterol in lipoprotein-X-positive serum Clin Chem 46 2000 1351 1356
    • (2000) Clin Chem , vol.46 , pp. 1351-1356
    • Fei, H.1    Maeda, S.2    Kirii, H.3    Fujigaki, S.4    Maekawa, N.5    Fujii, H.6
  • 10
    • 0031303729 scopus 로고    scopus 로고
    • Autoimmune hyperlipidemia with inhibitory monoclonal antibodies against low density lipoprotein binding to fibroblasts in a case with multiple myeloma
    • S. Nozaki, Y. Ito, T. Nakagawa, S. Yamashita, J. Sasaki, and Y. Matsuzawa Autoimmune hyperlipidemia with inhibitory monoclonal antibodies against low density lipoprotein binding to fibroblasts in a case with multiple myeloma Intern Med 36 1997 920 925
    • (1997) Intern Med , vol.36 , pp. 920-925
    • Nozaki, S.1    Ito, Y.2    Nakagawa, T.3    Yamashita, S.4    Sasaki, J.5    Matsuzawa, Y.6
  • 12
    • 0021261472 scopus 로고
    • Plasma cholesterol concentration and extra lipid band in monoclonal gammopathies
    • Y. Levy, M. Aviram, G. Spira, I. Tatarsky, G.J. Brook, and A. Carter Plasma cholesterol concentration and extra lipid band in monoclonal gammopathies Postgrad Med J 60 1984 449 453
    • (1984) Postgrad Med J , vol.60 , pp. 449-453
    • Levy, Y.1    Aviram, M.2    Spira, G.3    Tatarsky, I.4    Brook, G.J.5    Carter, A.6
  • 13
    • 0036275513 scopus 로고    scopus 로고
    • Monoclonal paraprotein may interfer with the Roche Direct HDL-C Plus Assay
    • N. Kadri, P. Douville, and P. Lachance Monoclonal paraprotein may interfer with the Roche Direct HDL-C Plus Assay Clin Chem 48 2002 964
    • (2002) Clin Chem , vol.48 , pp. 964
    • Kadri, N.1    Douville, P.2    Lachance, P.3
  • 14
    • 1642492769 scopus 로고    scopus 로고
    • Artifactual undetectable HDL-cholesterol with the Beckman Synchron LX and Vitros 950 Asssays temporally associated with a paraprotein
    • A. Baca, R.J. Haber, K. Sujishi, P.H. Frost, and V.L. Ng Artifactual undetectable HDL-cholesterol with the Beckman Synchron LX and Vitros 950 Asssays temporally associated with a paraprotein Clin Chem 50 2004 255 256
    • (2004) Clin Chem , vol.50 , pp. 255-256
    • Baca, A.1    Haber, R.J.2    Sujishi, K.3    Frost, P.H.4    Ng, V.L.5
  • 15
    • 0345035453 scopus 로고    scopus 로고
    • Multicenter evaluation on different analyzers of three methods for direct HDL-cholesterol assay
    • M. Egloff, D. Leglise, L. Duvillard, J. Steinmetz, M.J. Boyer, and A. Ruelland Multicenter evaluation on different analyzers of three methods for direct HDL-cholesterol assay Ann Biol Clin 57 1999 561 572
    • (1999) Ann Biol Clin , vol.57 , pp. 561-572
    • Egloff, M.1    Leglise, D.2    Duvillard, L.3    Steinmetz, J.4    Boyer, M.J.5    Ruelland, A.6
  • 17
    • 4244083800 scopus 로고    scopus 로고
    • Immunoglobulin interference in homogeneous HDL cholesterol methods
    • K. Kubono, I. Sakurabayashi, T. Nawa, and Y. Tsukada Immunoglobulin interference in homogeneous HDL cholesterol methods [Abstract] Clin Chem 46 2000 A98
    • (2000) Clin Chem , vol.46 , pp. 98
    • Kubono, K.1    Sakurabayashi, I.2    Nawa, T.3    Tsukada, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.