메뉴 건너뛰기




Volumn 46, Issue 2, 2005, Pages 360-365

Steps toward the percutaneous replacement of atrioventricular valves: An experimental study

Author keywords

[No Author keywords available]

Indexed keywords

NITINOL; POLITEF;

EID: 22044444705     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2005.01.063     Document Type: Article
Times cited : (109)

References (9)
  • 1
    • 0033901334 scopus 로고    scopus 로고
    • Transcatheter implantation of a bovine valve in pulmonary position: A lamb study
    • P. Bonhoeffer, Y. Boudjemline, Z. Saliba Transcatheter implantation of a bovine valve in pulmonary position a lamb study Circulation 102 2000 813 816
    • (2000) Circulation , vol.102 , pp. 813-816
    • Bonhoeffer, P.1    Boudjemline, Y.2    Saliba, Z.3
  • 2
    • 0036660253 scopus 로고    scopus 로고
    • Percutaneous implantation of a valve in the descending aorta in lambs
    • Y. Boudjemline, P. Bonhoeffer Percutaneous implantation of a valve in the descending aorta in lambs Eur Heart J 23 2002 1045 1049
    • (2002) Eur Heart J , vol.23 , pp. 1045-1049
    • Boudjemline, Y.1    Bonhoeffer, P.2
  • 3
    • 0037065848 scopus 로고    scopus 로고
    • Steps toward percutaneous aortic valve replacement
    • Y. Boudjemline, P. Bonhoeffer Steps toward percutaneous aortic valve replacement Circulation 105 2002 775 778
    • (2002) Circulation , vol.105 , pp. 775-778
    • Boudjemline, Y.1    Bonhoeffer, P.2
  • 4
    • 0034699902 scopus 로고    scopus 로고
    • Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction
    • P. Bonhoeffer, Y. Boudjemline, Z. Saliba Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction Lancet 356 2000 1403 1405
    • (2000) Lancet , vol.356 , pp. 1403-1405
    • Bonhoeffer, P.1    Boudjemline, Y.2    Saliba, Z.3
  • 6
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • A. Cribier, H. Eltchaninoff, A. Bash Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis first human case description Circulation 106 2002 3006 3008
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 7
    • 0142023864 scopus 로고    scopus 로고
    • Endovascular edge-to-edge mitral valve repair: Short-term results in a porcine model
    • F.G. St. Goar, J.I. Fann, J. Komtebedde Endovascular edge-to-edge mitral valve repair short-term results in a porcine model Circulation 108 2003 1990 1993
    • (2003) Circulation , vol.108 , pp. 1990-1993
    • St. Goar, F.G.1    Fann, J.I.2    Komtebedde, J.3
  • 8
    • 0242385578 scopus 로고    scopus 로고
    • Percutaneous mitral valve repair: A feasibility study in an ovine model of acute ischemic mitral regurgitation
    • J.R. Liddicoat, B.D. Mac Neill, A.M. Gillinov Percutaneous mitral valve repair a feasibility study in an ovine model of acute ischemic mitral regurgitation Catheter Cardiovasc Interv 60 2003 410 416
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 410-416
    • Liddicoat, J.R.1    Mac Neill, B.D.2    Gillinov, A.M.3
  • 9
    • 1642307504 scopus 로고    scopus 로고
    • European Convention for the Protection of Animals Used for Experimental or Scientific Works
    • August 24
    • European Convention for the Protection of Animals Used for Experimental or Scientific Works. Official Journal of the European Community. L222/29-L222/37. August 24, 1999.
    • (1999) Official Journal of the European Community


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.