메뉴 건너뛰기




Volumn 41, Issue 5, 2005, Pages 1928-1931

Design of post-assembly magnetization system of line start permanent-magnet motors using FEM

Author keywords

Design method; Design procedure; Line start permanent magnet (LSPM); Post assembly magnetization system

Indexed keywords

EDDY CURRENTS; ELECTRIC COILS; ELECTRIC LINES; ELECTRIC POTENTIAL; FINITE ELEMENT METHOD; INDUCTION MOTORS; MAGNETIZATION; ROTORS;

EID: 22044443328     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMAG.2005.846501     Document Type: Article
Times cited : (32)

References (4)
  • 1
    • 0031360528 scopus 로고    scopus 로고
    • Performance of skewed single phase line-start permanent magnet motors
    • New Orleans, LA, Oct.
    • S. Williamson and A. M. Knight, "Performance of skewed single phase line-start permanent magnet motors," in IEEE Industry Applications Soc. Annu. Meeting, New Orleans, LA, Oct. 1997.
    • (1997) IEEE Industry Applications Soc. Annu. Meeting
    • Williamson, S.1    Knight, A.M.2
  • 2
    • 0037506864 scopus 로고    scopus 로고
    • Analysis of magnetization of magnet in the rotor of line start permanent magnet motor
    • May
    • C. K. Lee et al., "Analysis of magnetization of magnet in the rotor of line start permanent magnet motor," IEEE Trans. Magn., vol. 39, no. 3, pp. 1499-1452, May 2003.
    • (2003) IEEE Trans. Magn. , vol.39 , Issue.3 , pp. 1499-11452
    • Lee, C.K.1
  • 3
    • 0026911501 scopus 로고
    • Computer-aided design of magnetizing fixtures for the post-assembly magnetization of rare-earth permanent magnet brushless DC motors
    • Sep.
    • G. W. Jewell and D. Howe, "Computer-aided design of magnetizing fixtures for the post-assembly magnetization of rare-earth permanent magnet brushless DC motors," IEEE Trans. Magn., vol. 28, no. 5, pp. 3036-3038, Sep. 1992.
    • (1992) IEEE Trans. Magn. , vol.28 , Issue.5 , pp. 3036-3038
    • Jewell, G.W.1    Howe, D.2
  • 4
    • 22044446734 scopus 로고    scopus 로고
    • Study on the development of 3.7 [kW] line start permanent magnet motor
    • Hyosung Corporation, Korea
    • S. D. Oh et al., "Study on the development of 3.7 [kW] line start permanent magnet motor," Hyosung Corporation, Korea, Tech. Rep., 2002.
    • (2002) Tech. Rep.
    • Oh, S.D.1