메뉴 건너뛰기




Volumn 21, Issue 2, 2005, Pages 293-302

Bacteria detection using disposable optical leaky waveguide sensors

Author keywords

Bacteria detection; Biosensor; Disposable sensor; Evanescent wave sensor; Leaky waveguide; Optical waveguide

Indexed keywords

ANTIBODIES; BACTERIA; FLUORESCENCE; MICROPROCESSOR CHIPS; OPTICAL WAVEGUIDES; REFRACTIVE INDEX; SCATTERING; SURFACE PLASMON RESONANCE;

EID: 22044434435     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bios.2004.10.013     Document Type: Article
Times cited : (61)

References (28)
  • 2
    • 0036096446 scopus 로고    scopus 로고
    • Detection of infectious and toxigenic bacteria
    • A.K. Deisingh, and M. Thompson Detection of infectious and toxigenic bacteria Analyst 127 2002 567 581
    • (2002) Analyst , vol.127 , pp. 567-581
    • Deisingh, A.K.1    Thompson, M.2
  • 3
    • 32644472487 scopus 로고    scopus 로고
    • Biosensors for microbial detection
    • A. Deisingh Biosensors for microbial detection Microbiologist 2003 30 33
    • (2003) Microbiologist , pp. 30-33
    • Deisingh, A.1
  • 4
    • 0033166564 scopus 로고    scopus 로고
    • Rapid detection of Escherichia coli O157:H7 in ground beef using fibre-optic biosensor
    • D.R. DeMarco, E.W. Saaski, D.A. McCrae, and D.V. Lim Rapid detection of Escherichia coli O157:H7 in ground beef using fibre-optic biosensor J. Food Protect. 62 1999 711 716
    • (1999) J. Food Protect. , vol.62 , pp. 711-716
    • Demarco, D.R.1    Saaski, E.W.2    McCrae, D.A.3    Lim, D.V.4
  • 5
    • 0347917927 scopus 로고    scopus 로고
    • Direct detection of Escherichia coli O157:H7 in unpastuerized apple juice with an evanescent wave sensor
    • D.R. DeMarco, and D.V. Lim Direct detection of Escherichia coli O157:H7 in unpastuerized apple juice with an evanescent wave sensor J. Rapid Meth. Automation Micro 9 2001 241 257
    • (2001) J. Rapid Meth. Automation Micro , vol.9 , pp. 241-257
    • Demarco, D.R.1    Lim, D.V.2
  • 6
    • 0032808620 scopus 로고    scopus 로고
    • Aerobiological pathogen detection by evanescent wave fibre optic sensor
    • A.P. Ferreira, M.M. Werneck, and R.M. Ribeiro Aerobiological pathogen detection by evanescent wave fibre optic sensor Biotechnol. Tech. 13 1999 447 452
    • (1999) Biotechnol. Tech. , vol.13 , pp. 447-452
    • Ferreira, A.P.1    Werneck, M.M.2    Ribeiro, R.M.3
  • 7
    • 0034896245 scopus 로고    scopus 로고
    • Development of an evanescent-field fibre optic sensor for Escherichia coli O157:H7
    • A.P. Ferreria, M.M. Werneck, and R.M. Ribeiro Development of an evanescent-field fibre optic sensor for Escherichia coli O157:H7 Biosens. Bioeletron. 16 2001 399 408
    • (2001) Biosens. Bioeletron. , vol.16 , pp. 399-408
    • Ferreria, A.P.1    Werneck, M.M.2    Ribeiro, R.M.3
  • 8
    • 0031872669 scopus 로고    scopus 로고
    • Detection of Escherichia coli 0157:H7 using a surface plasmon resonance sensor
    • P. Fratamico, T. Strobaugh, M. Medina, and A. Gehring Detection of Escherichia coli 0157:H7 using a surface plasmon resonance sensor Biotechnol. Tech. 127 1998 571 576
    • (1998) Biotechnol. Tech. , vol.127 , pp. 571-576
    • Fratamico, P.1    Strobaugh, T.2    Medina, M.3    Gehring, A.4
  • 10
    • 0032626631 scopus 로고    scopus 로고
    • Surface plasmon resonance sensors: Review
    • J. Homola, S.S. Yee, and G. Gauglitz Surface plasmon resonance sensors: review Sensor Actuat. B 54 1999 3 15
    • (1999) Sensor Actuat. B , vol.54 , pp. 3-15
    • Homola, J.1    Yee, S.S.2    Gauglitz, G.3
  • 11
    • 0042845473 scopus 로고    scopus 로고
    • Rapid protoyping for injection moulded integrated microfluidic devices and diffractive element arrays
    • J. Hulme, S. Mohr, P.R. Fielden, and N.J. Goddard Rapid protoyping for injection moulded integrated microfluidic devices and diffractive element arrays Lab Chip 4 2002 203 206
    • (2002) Lab Chip , vol.4 , pp. 203-206
    • Hulme, J.1    Mohr, S.2    Fielden, P.R.3    Goddard, N.J.4
  • 13
    • 0033674287 scopus 로고    scopus 로고
    • Detection of PCR products of Escherichia coli O157:H7 in human stool samples using surface plasmon resonance (SPR)
    • E. Kai, K. Ikebukuro, S. Hoshina, H. Watanabe, and I. Karube Detection of PCR products of Escherichia coli O157:H7 in human stool samples using surface plasmon resonance (SPR) FEMS Immunol. Med. Microb. 29 2000 283 288
    • (2000) FEMS Immunol. Med. Microb. , vol.29 , pp. 283-288
    • Kai, E.1    Ikebukuro, K.2    Hoshina, S.3    Watanabe, H.4    Karube, I.5
  • 15
    • 1642363929 scopus 로고    scopus 로고
    • A generic approach for the detection of whole Listeria monocytogenes cells in contaminated samples using surface plasmon resonance
    • P. Leonard, S. Hearty, J. Quinn, and R. O'Kennedy A generic approach for the detection of whole Listeria monocytogenes cells in contaminated samples using surface plasmon resonance Biosens. Bioelectron. 19 2004 1331 1335
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 1331-1335
    • Leonard, P.1    Hearty, S.2    Quinn, J.3    O'Kennedy, R.4
  • 16
    • 0031041314 scopus 로고    scopus 로고
    • Quantitative analysis of bacterial toxin affinity and specificity for glycolipid receptors by SPR
    • C.R. Mackenzie, T. Hirama, K.K. Lee, E. Altaman, and N.M. Young Quantitative analysis of bacterial toxin affinity and specificity for glycolipid receptors by SPR J. Biol. Chem. 272 1997 5533 5538
    • (1997) J. Biol. Chem. , vol.272 , pp. 5533-5538
    • MacKenzie, C.R.1    Hirama, T.2    Lee, K.K.3    Altaman, E.4    Young, N.M.5
  • 18
    • 0030988945 scopus 로고    scopus 로고
    • Real-time analysis of antibody binding interactions with immobilized E. coli O157:H7 cells using the BIAcore
    • M. Medina, L. Houten, P. Cooke, and S. Tu Real-time analysis of antibody binding interactions with immobilized E. coli O157:H7 cells using the BIAcore Biotechnol. Tech. 11 1997 173 176
    • (1997) Biotechnol. Tech. , vol.11 , pp. 173-176
    • Medina, M.1    Houten, L.2    Cooke, P.3    Tu, S.4
  • 19
    • 0033959461 scopus 로고    scopus 로고
    • Development of instrumentation to allow the detection of microorganisms using light scattering in combination with surface plasmon resonance
    • E. Perkins, and D. Squirrell Development of instrumentation to allow the detection of microorganisms using light scattering in combination with surface plasmon resonance Biosens. Bioelectron. 14 2000 853 859
    • (2000) Biosens. Bioelectron. , vol.14 , pp. 853-859
    • Perkins, E.1    Squirrell, D.2
  • 21
    • 0032538722 scopus 로고    scopus 로고
    • Optical determination of molecule diffusion coefficients in polymer films
    • P. Podgorsek, and H. Franke Optical determination of molecule diffusion coefficients in polymer films Appl. Phys. Lett. 73 1998 2887 2889
    • (1998) Appl. Phys. Lett. , vol.73 , pp. 2887-2889
    • Podgorsek, P.1    Franke, H.2
  • 22
    • 0034022185 scopus 로고    scopus 로고
    • Observing secretory granules with a multi-angle evanescent wave microscope
    • A. Rohrabach Observing secretory granules with a multi-angle evanescent wave microscope Biophys. J. 78 2000 2641 2654
    • (2000) Biophys. J. , vol.78 , pp. 2641-2654
    • Rohrabach, A.1
  • 23
    • 0028487452 scopus 로고
    • Optical biosensor for monitoring microbial cells
    • H. Watts, C. Lowe, and D. Pollard-Knight Optical biosensor for monitoring microbial cells Anal. Chem. 66 1994 2465 2470
    • (1994) Anal. Chem. , vol.66 , pp. 2465-2470
    • Watts, H.1    Lowe, C.2    Pollard-Knight, D.3
  • 24
    • 0021072944 scopus 로고
    • Suggested bacteriological standards for air in ultraclean operating rooms
    • W. Whyte, O.M. Lidwell, E.J. Lowbury, and R. Blowers Suggested bacteriological standards for air in ultraclean operating rooms J. Hosp. Infect. 4 1983 133 139
    • (1983) J. Hosp. Infect. , vol.4 , pp. 133-139
    • Whyte, W.1    Lidwell, O.M.2    Lowbury, E.J.3    Blowers, R.4
  • 25
    • 0037457545 scopus 로고    scopus 로고
    • The development of a metal clad leaky waveguide sensor for the detection of particles
    • M. Zourob, S. Mohr, P.R. Fielden, and N.J. Goddard The development of a metal clad leaky waveguide sensor for the detection of particles Sensor Actuat. B 90 2003 296 307
    • (2003) Sensor Actuat. B , vol.90 , pp. 296-307
    • Zourob, M.1    Mohr, S.2    Fielden, P.R.3    Goddard, N.J.4
  • 26
    • 0041590897 scopus 로고    scopus 로고
    • Small-volume refractive index and fluorescence sensor for μ-TAS applications
    • M. Zourob, S. Mohr, P.R. Fielden, and N.J. Goddard Small-volume refractive index and fluorescence sensor for μ-TAS applications Sensor Actuat. B 94 2003 304 312
    • (2003) Sensor Actuat. B , vol.94 , pp. 304-312
    • Zourob, M.1    Mohr, S.2    Fielden, P.R.3    Goddard, N.J.4
  • 27
    • 12844252478 scopus 로고    scopus 로고
    • An integrated metal clad leaky waveguide sensor for detection of bacteria
    • (in press).
    • Zourob, M., Mohr, S., Fielden, P.R., Goddard, N.J., 2004. An integrated metal clad leaky waveguide sensor for detection of bacteria. Anal. Chem. (in press).
    • (2004) Anal. Chem.
    • Zourob, M.1    Mohr, S.2    Fielden, P.R.3    Goddard, N.J.4
  • 28
    • 32644485145 scopus 로고    scopus 로고
    • An integrated disposable dye clad leaky waveguide sensor for μ-TAS applications
    • submitted for publication.
    • Zourob, M., Mohr, S., Fielden, P.R., Goddard, N.J., submitted for publication. An integrated disposable dye clad leaky waveguide sensor for μ-TAS applications. Sensors Actuat.
    • Sensors Actuat.
    • Zourob, M.1    Mohr, S.2    Fielden, P.R.3    Goddard, N.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.