메뉴 건너뛰기




Volumn 23, Issue 4, 2005, Pages 720-725

A new approach for the Martell 3-D method of measuring polyethylene wear without requiring the cross-table lateral films

Author keywords

Polyethylene; Radiograph; Total hip replacement; Wear

Indexed keywords

POLYETHYLENE;

EID: 21844450199     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.orthres.2004.07.008     Document Type: Article
Times cited : (19)

References (21)
  • 1
    • 0003415539 scopus 로고    scopus 로고
    • Practical statistics for medical research
    • editor. 1999 Chapman and Hall London
    • D.G. Altman Practical statistics for medical research 1999 Chapman and Hall London
    • (1999)
    • Altman, D.G.1
  • 3
    • 0036316748 scopus 로고    scopus 로고
    • Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model
    • C.R. Bragdon et al. Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model J Orthop Res 20 4 2002 688-695
    • (2002) J. Orthop. Res. , vol.20 , Issue.4 , pp. 688-695
    • Bragdon, C.R.1
  • 4
    • 1842853898 scopus 로고    scopus 로고
    • Comparison of two digital radiostereometric analysis (RSA) methods in the determination of femoral head penetration in a total hip replacement phantom
    • C.R. Bragdon et al. Comparison of two digital radiostereometric analysis (RSA) methods in the determination of femoral head penetration in a total hip replacement phantom J Orthop Res 22 3 2004 659-664
    • (2004) J. Orthop. Res. , vol.22 , Issue.3 , pp. 659-664
    • Bragdon, C.R.1
  • 5
    • 0018098587 scopus 로고
    • Radiographic evaluation of scoliosis: A reassessment and introduction of the scoliosis Chariot
    • E.G. Dawson R.K. Smith G.M. McNiece Radiographic evaluation of scoliosis: A reassessment and introduction of the scoliosis Chariot Clin Orthop Relat Res (131) 1978 151-155
    • (1978) Clin. Orthop. Relat. Res. , Issue.131 , pp. 151-155
    • Dawson, E.G.1    Smith, R.K.2    McNiece, G.M.3
  • 6
    • 0028820598 scopus 로고
    • Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique
    • P.A. Devane et al. Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique Clin Orthop Relat Res (319) 1995 303-316
    • (1995) Clin. Orthop. Relat. Res. , Issue.319 , pp. 303-316
    • Devane, P.A.1
  • 7
    • 0030960089 scopus 로고    scopus 로고
    • Measurement of polyethylene wear in acetabular components inserted with and without cement. A randomized trial
    • [see comments]
    • P.A. Devane et al. Measurement of polyethylene wear in acetabular components inserted with and without cement. A randomized trial [see comments] J Bone Joint Surg-Am Vol 79 5 1997 682-689
    • (1997) J. Bone Joint Surg.-Am. Vol. , vol.79 , Issue.5 , pp. 682-689
    • Devane, P.A.1
  • 8
    • 0344927558 scopus 로고    scopus 로고
    • Assessment of polyethylene wear in total hip replacement
    • P.A. Devane J.G. Horne Assessment of polyethylene wear in total hip replacement Clin Orthop Relat Res (369) 1999 59-72
    • (1999) Clin. Orthop. Relat. Res. , Issue.369 , pp. 59-72
    • Devane, P.A.1    Horne, J.G.2
  • 9
    • 0025797538 scopus 로고
    • Measurement of hip prostheses using image analysis. The maxima hip technique
    • K. Hardinge et al. Measurement of hip prostheses using image analysis. The maxima hip technique J Bone Joint Surg-Brit Vol 73 5 1991 724-748
    • (1991) J. Bone Joint Surg.-Brit. Vol. , vol.73 , Issue.5 , pp. 724-748
    • Hardinge, K.1
  • 10
    • 0037364257 scopus 로고    scopus 로고
    • Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty
    • A.J. Hui et al. Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty J Bone Joint Surg-Am Vol 85-A 3 2003 505-511
    • (2003) J. Bone Joint Surg.-Am. Vol. , vol.85 A , Issue.3 , pp. 505-511
    • Hui, A.J.1
  • 11
    • 0038236572 scopus 로고    scopus 로고
    • Measurement of polyethylene wear in total hip arthroplasty - Accuracy versus ease of use
    • J.S. Kang et al. Measurement of polyethylene wear in total hip arthroplasty - Accuracy versus ease of use Yonsei Med J 44 3 2003 473-478
    • (2003) Yonsei Med. J. , vol.44 , Issue.3 , pp. 473-478
    • Kang, J.S.1
  • 12
    • 0020569584 scopus 로고
    • Radiographic techniques for consistent visualization of total hip arthroplasties
    • J.S. Kirkpatrick et al. Radiographic techniques for consistent visualization of total hip arthroplasties Clin Orthop Relat Res (174) 1983 158-163
    • (1983) Clin. Orthop. Relat. Res. , Issue.174 , pp. 158-163
    • Kirkpatrick, J.S.1
  • 13
    • 32644480362 scopus 로고    scopus 로고
    • Polyethylene wear in total hip arthoplasty
    • J.T. Livermore Polyethylene wear in total hip arthoplasty Semin Arthoplast 7 1 1996 40-46
    • (1996) Semin. Arthoplast. , vol.7 , Issue.1 , pp. 40-46
    • Livermore, J.T.1
  • 14
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • J. Livermore D. Ilstrup B. Morrey Effect of femoral head size on wear of the polyethylene acetabular component J Bone Joint Surg 72-A 1990 518-528
    • (1990) J. Bone Joint Surg. , vol.72 A , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 15
    • 0030669292 scopus 로고    scopus 로고
    • Determination of polyethylene wear in total hip replacements with use of digital radiographs
    • J.M. Martell S. Berdia Determination of polyethylene wear in total hip replacements with use of digital radiographs J Bone Joint Surg-Am Vol 79 11 1997 1635-1641
    • (1997) J. Bone Joint Surg.-Am. Vol. , vol.79 , Issue.11 , pp. 1635-1641
    • Martell, J.M.1    Berdia, S.2
  • 16
    • 0038351040 scopus 로고    scopus 로고
    • Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty
    • J.M. Martell et al. Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty J Bone Joint Surg-Am Vol 85-A 6 2003 1111-1117
    • (2003) J. Bone Joint Surg.-Am. Vol. , vol.85 A , Issue.6 , pp. 1111-1117
    • Martell, J.M.1
  • 17
    • 0035207945 scopus 로고    scopus 로고
    • A clinically practical method of manually assessing polyethylene liner thickness
    • D. Pollock C.J. Sychterz C.A. Engh Sr. A clinically practical method of manually assessing polyethylene liner thickness J Bone Joint Surg-Am Vol 83-A 12 2001 1803-1809
    • (2001) J. Bone Joint Surg.-Am. Vol. , vol.83 A , Issue.12 , pp. 1803-1809
    • Pollock, D.1    Sychterz, C.J.2    Engh, C.A.3
  • 18
    • 0030923843 scopus 로고    scopus 로고
    • Digital edge-detection measurement of polyethylene wear after total hip arthroplasty
    • S.M. Shaver et al. Digital edge-detection measurement of polyethylene wear after total hip arthroplasty J Bone Joint Surg-Am Vol 79 5 1997 690-700
    • (1997) J. Bone Joint Surg.-Am. Vol. , vol.79 , Issue.5 , pp. 690-700
    • Shaver, S.M.1
  • 19
    • 0030746652 scopus 로고    scopus 로고
    • Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time
    • C.J. Sychterz et al. Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time J Bone Joint Surg-Am Vol 79 7 1997 1040-1046
    • (1997) J. Bone Joint Surg.-Am. Vol. , vol.79 , Issue.7 , pp. 1040-1046
    • Sychterz, C.J.1
  • 20
    • 0032782846 scopus 로고    scopus 로고
    • Two-dimensional versus three-dimensional radiographic measurements of polyethylene wear
    • C.J. Sychterz et al. Two-dimensional versus three-dimensional radiographic measurements of polyethylene wear Clin Orthop Relat Res 365 1999 117-123
    • (1999) Clin. Orthop. Relat. Res. , Issue.365 , pp. 117-123
    • Sychterz, C.J.1
  • 21
    • 0030666239 scopus 로고    scopus 로고
    • Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups
    • M. Yamaguchi T.W. Bauer Y. Hashimoto Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups J Bone Joint Surg-Am Vol 79 10 1997 1539-1544
    • (1997) J. Bone Joint Surg.-Am. Vol. , vol.79 , Issue.10 , pp. 1539-1544
    • Yamaguchi, M.1    Bauer, T.W.2    Hashimoto, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.