메뉴 건너뛰기




Volumn 119, Issue 4, 2005, Pages 185-194

Temperature-based death time estimation with only partially known environmental conditions

Author keywords

Postmortem cooling; Temperature model; Time since death

Indexed keywords

ARTICLE; AUTOPSY; BODY TEMPERATURE; DEATH; ENVIRONMENTAL TEMPERATURE; HUMAN; MATHEMATICAL MODEL; MEDICOLEGAL ASPECT; PRIORITY JOURNAL; RECTUM TEMPERATURE; TEMPERATURE MEASUREMENT; THEORETICAL STUDY;

EID: 21744457927     PISSN: 09379827     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00414-004-0461-4     Document Type: Article
Times cited : (30)

References (24)
  • 1
    • 0037127390 scopus 로고    scopus 로고
    • A study of the shape of the post-mortem cooling curve in 117 forensic cases
    • Al Alousi LM (2002) A study of the shape of the post-mortem cooling curve in 117 forensic cases. Forensic Sci Int 125:237-244
    • (2002) Forensic Sci Int , vol.125 , pp. 237-244
    • Al Alousi, L.M.1
  • 2
    • 0035051472 scopus 로고    scopus 로고
    • Multiple-probe thermography for estimating the postmortem interval: I. Continuous monitoring and data analysis of brain, liver, rectal and environmental temperature in 117 forensic cases
    • Al Alousi LM, Anderson RA, Worster DM, Land DV (2001) Multiple-probe thermography for estimating the postmortem interval: I. Continuous monitoring and data analysis of brain, liver, rectal and environmental temperature in 117 forensic cases. J Forensic Sci 46:317-322
    • (2001) J Forensic Sci , vol.46 , pp. 317-322
    • Al Alousi, L.M.1    Anderson, R.A.2    Worster, D.M.3    Land, D.V.4
  • 3
    • 0035048370 scopus 로고    scopus 로고
    • Multiple-probe thermography for estimating the postmortem interval: II. Practical versions of the triple-exponential formulae (TEF) for estimating the time of death in the field
    • Al Alousi LM, Anderson RA, Worster DM, Land DV (2001) Multiple-probe thermography for estimating the postmortem interval: II. Practical versions of the triple-exponential formulae (TEF) for estimating the time of death in the field. J Forensic Sci 46:323-327
    • (2001) J Forensic Sci , vol.46 , pp. 323-327
    • Al Alousi, L.M.1    Anderson, R.A.2    Worster, D.M.3    Land, D.V.4
  • 4
    • 0037127402 scopus 로고    scopus 로고
    • Factors influencing the precision of estimating the postmortem interval using the triple-exponential formulae (TEF) Part I. A study of the effect of body variables and covering of the torso on the postmortem brain, liver and rectal cooling rates in 117 forensic cases
    • Al Alousi LM, Anderson RA, Worster DM, Land DV (2002) Factors influencing the precision of estimating the postmortem interval using the triple-exponential formulae (TEF) Part I. A study of the effect of body variables and covering of the torso on the postmortem brain, liver and rectal cooling rates in 117 forensic cases. Forensic Sci Int 125:223-230
    • (2002) Forensic Sci Int , vol.125 , pp. 223-230
    • Al Alousi, L.M.1    Anderson, R.A.2    Worster, D.M.3    Land, D.V.4
  • 5
    • 0037127392 scopus 로고    scopus 로고
    • Factors influencing the precision of estimating the postmortem interval using the triple-exponential formulae (TEF) Part II. A study of the effect of body temperature at the moment of death on postmortem brain, liver and rectal cooling in 117 forensic cases
    • Al Alousi LM, Anderson RA, Worster DM, Land DV (2002) Factors influencing the precision of estimating the postmortem interval using the triple-exponential formulae (TEF) Part II. A study of the effect of body temperature at the moment of death on postmortem brain, liver and rectal cooling in 117 forensic cases. Forensic Sci Int 125:231-236
    • (2002) Forensic Sci Int , vol.125 , pp. 231-236
    • Al Alousi, L.M.1    Anderson, R.A.2    Worster, D.M.3    Land, D.V.4
  • 6
    • 0032904981 scopus 로고    scopus 로고
    • Rectal temperature of death nomogram: Sudden change of ambient temperature
    • Althaus L, Henssge C (1999) Rectal temperature of death nomogram: sudden change of ambient temperature. Forensic Sci Int 99:171-178
    • (1999) Forensic Sci Int , vol.99 , pp. 171-178
    • Althaus, L.1    Henssge, C.2
  • 8
    • 0016300322 scopus 로고
    • Body temperature as a means of estimating the time of death
    • Brown A, Marshall TK (1974) Body temperature as a means of estimating the time of death. Forensic Sci 4:125-133
    • (1974) Forensic Sci , vol.4 , pp. 125-133
    • Brown, A.1    Marshall, T.K.2
  • 10
    • 0002279865 scopus 로고
    • A percentage method for representing the fall in body temperature after death
    • Fiddes FS, Patten TD (1958) A percentage method for representing the fall in body temperature after death. J Forensic Med 5:2-15
    • (1958) J Forensic Med , vol.5 , pp. 2-15
    • Fiddes, F.S.1    Patten, T.D.2
  • 11
    • 0021802421 scopus 로고
    • Postmortem interval estimation from body temperature data only
    • Green MA, Wright JC (1985) Postmortem interval estimation from body temperature data only. Forensic Sci Int 28:35-46
    • (1985) Forensic Sci Int , vol.28 , pp. 35-46
    • Green, M.A.1    Wright, J.C.2
  • 12
    • 0021821542 scopus 로고
    • The theoretical aspects of the time dependent Z equation as a means of postmortem interval estimation using body temperature data only
    • Green MA, Wright JC (1985) The theoretical aspects of the time dependent Z equation as a means of postmortem interval estimation using body temperature data only. Forensic Sci Int 28:53-62
    • (1985) Forensic Sci Int , vol.28 , pp. 53-62
    • Green, M.A.1    Wright, J.C.2
  • 13
    • 0018756555 scopus 로고
    • Die Präzision von Todeszeitschätzungen durch die mathematische Beschreibung der rektalen Leichenabkühlung
    • Henssge C (1979) Die Präzision von Todeszeitschätzungen durch die mathematische Beschreibung der rektalen Leichenabkühlung. Z Rechtsmed 83:49-67
    • (1979) Z Rechtsmed , vol.83 , pp. 49-67
    • Henssge, C.1
  • 14
    • 0019468784 scopus 로고
    • Todeszeitschätzungen durch die mathematische Beschreibung der rektalen Leichenabkühlung unter verschiedenen Abkühlbedingungen
    • Henssge C (1981) Todeszeitschätzungen durch die mathematische Beschreibung der rektalen Leichenabkühlung unter verschiedenen Abkühlbedingungen. Z Rechtsmed 87:147-178
    • (1981) Z Rechtsmed , vol.87 , pp. 147-178
    • Henssge, C.1
  • 16
    • 0033785671 scopus 로고    scopus 로고
    • Experiences with a compound method for estimating the time since death. I. Rectal temperature nomogram for the time since death
    • Henssge C, Althaus L, Bolt J et al. (2000) Experiences with a compound method for estimating the time since death. I. Rectal temperature nomogram for the time since death. Int J Legal Med 113:303-319
    • (2000) Int J Legal Med , vol.113 , pp. 303-319
    • Henssge, C.1    Althaus, L.2    Bolt, J.3
  • 17
    • 0033785672 scopus 로고    scopus 로고
    • Experiences with a compound method for estimating the time since death. II. Integration of non-temperature based methods
    • Henssge C, Althaus L, Bolt J et al. (2000) Experiences with a compound method for estimating the time since death. II. Integration of non-temperature based methods. Int J Legal Med 113:320-331
    • (2000) Int J Legal Med , vol.113 , pp. 320-331
    • Henssge, C.1    Althaus, L.2    Bolt, J.3
  • 18
    • 0009897186 scopus 로고
    • Physical and chemical methods for the estimation of the time since death
    • Lundquist F (1956) Physical and chemical methods for the estimation of the time since death, Acta Med Leg Soc 9:205-213
    • (1956) Acta Med Leg Soc , vol.9 , pp. 205-213
    • Lundquist, F.1
  • 19
    • 0343442427 scopus 로고    scopus 로고
    • Determination of time-dependent skin temperature decrease rates in the case of abrupt changes of environmental temperature
    • Mall G, Hubig M, Beier G, Büttner A, Eisenmenger W (2000) Determination of time-dependent skin temperature decrease rates in the case of abrupt changes of environmental temperature. Forensic Sci Int 113:219-226
    • (2000) Forensic Sci Int , vol.113 , pp. 219-226
    • Mall, G.1    Hubig, M.2    Beier, G.3    Büttner, A.4    Eisenmenger, W.5
  • 20
    • 0036732497 scopus 로고    scopus 로고
    • Modelling postmortem surface cooling in continuously changing environmental temperature
    • Mall G, Hubig M, Eckl M, Büttner A, Eisenmenger W (2002) Modelling postmortem surface cooling in continuously changing environmental temperature. Legal Med 4:164-173
    • (2002) Legal Med , vol.4 , pp. 164-173
    • Mall, G.1    Hubig, M.2    Eckl, M.3    Büttner, A.4    Eisenmenger, W.5
  • 21
    • 0002841198 scopus 로고
    • Estimating the time of death - The rectal cooling after death and its mathematical expression
    • Marshall TK, Hoare FE (1962) Estimating the time of death - The rectal cooling after death and its mathematical expression. J Forensic Sci 7:56-81
    • (1962) J Forensic Sci , vol.7 , pp. 56-81
    • Marshall, T.K.1    Hoare, F.E.2
  • 22
    • 0002841198 scopus 로고
    • Estimating the time of death - The use of the cooling formula in the study of postmortem body cooling
    • Marshall TK, Hoare FE (1962) Estimating the time of death - The use of the cooling formula in the study of postmortem body cooling. J Forensic Sci 7:189-210
    • (1962) J Forensic Sci , vol.7 , pp. 189-210
    • Marshall, T.K.1    Hoare, F.E.2
  • 23
    • 0002841198 scopus 로고
    • Estimating the time of death - The use of body temperature in estimating the time of death
    • Marshall TK, Hoare FE (1962) Estimating the time of death - The use of body temperature in estimating the time of death. J Forensic Sci 7:211-221
    • (1962) J Forensic Sci , vol.7 , pp. 211-221
    • Marshall, T.K.1    Hoare, F.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.