1
-
-
0031239541
-
Numerical modeling of UV intensity: Application to collimated beam reactor and continuous flow systems
-
E.R. Blatchley III Numerical modeling of UV intensity: application to collimated beam reactor and continuous flow systems Water Res. 31 9 1997 2205 2208
-
(1997)
Water Res.
, vol.31
, Issue.9
, pp. 2205-2208
-
-
Blatchley III, E.R.1
-
2
-
-
0034285029
-
Calculation of ultraviolet fluence rate distributions in an annular reactor: Significance of refraction and reflection
-
J.R. Bolton Calculation of ultraviolet fluence rate distributions in an annular reactor: significance of refraction and reflection Water Res. 34 13 2000 3315 3324
-
(2000)
Water Res.
, vol.34
, Issue.13
, pp. 3315-3324
-
-
Bolton, J.R.1
-
4
-
-
0015627846
-
Radiation profiles in an empty annular photoreactor with a source of finite spatial dimensions
-
H.A. Irazoqui, J. Cerda, and A.E. Cassano Radiation profiles in an empty annular photoreactor with a source of finite spatial dimensions AIChE J. 19 1973 460 468
-
(1973)
AIChE J.
, vol.19
, pp. 460-468
-
-
Irazoqui, H.A.1
Cerda, J.2
Cassano, A.E.3
-
5
-
-
84984095096
-
Light intensity profiles in a perfectly mixed photoreactor
-
S.M. Jacob, and J.S. Dranoff Light intensity profiles in a perfectly mixed photoreactor AIChE J. 16 3 1970 359 364
-
(1970)
AIChE J.
, vol.16
, Issue.3
, pp. 359-364
-
-
Jacob, S.M.1
Dranoff, J.S.2
-
6
-
-
32644479469
-
Determination of fluence rate distribution in UV reactors using spherical actinometry and mathematical analysis approaches
-
CDROM, Seattle, WA, American Water Works Association, Denver, CO.
-
Jin, S., Linden, K.G., Ducoste, J., 2002. Determination of fluence rate distribution in UV reactors using spherical actinometry and mathematical analysis approaches. Proceedings of the Water Quality Technology Conference, CDROM, Seattle, WA, American Water Works Association, Denver, CO.
-
(2002)
Proceedings of the Water Quality Technology Conference
-
-
Jin, S.1
Linden, K.G.2
Ducoste, J.3
-
7
-
-
6344252713
-
Evaluation of fluence rate distribution models
-
D. Liu, J. Ducoste, S. Jin, and K. Linden Evaluation of fluence rate distribution models J. Water Supply Res. AQUA 53 6 2004 391 408
-
(2004)
J. Water Supply Res. AQUA
, vol.53
, Issue.6
, pp. 391-408
-
-
Liu, D.1
Ducoste, J.2
Jin, S.3
Linden, K.4
-
9
-
-
0001218464
-
Potassium iodide as a chemical actinometer for 254 nm radiation: Use of iodate as an electron scavenger
-
R.O. Rahn Potassium iodide as a chemical actinometer for 254 nm radiation: use of iodate as an electron scavenger Photochem. Photobiol. 66 4 1997 450 455
-
(1997)
Photochem. Photobiol.
, vol.66
, Issue.4
, pp. 450-455
-
-
Rahn, R.O.1
-
11
-
-
0033194783
-
Dosimetry of room-air germicidal (254 nm) radiation using spherical actinometry
-
R.O. Rahn, P. Xu, and S.L. Miller Dosimetry of room-air germicidal (254 nm) radiation using spherical actinometry Photochem. Photobiol. 70 3 1999 314 318
-
(1999)
Photochem. Photobiol.
, vol.70
, Issue.3
, pp. 314-318
-
-
Rahn, R.O.1
Xu, P.2
Miller, S.L.3
-
12
-
-
6344230731
-
The iodide/iodate actinometer in UV disinfection: Characteristics and use in the determination of the fluence rate distribution in UV reactors
-
CDROM, Salt Lake City, UT, American Water Works Association, Denver, CO.
-
Rahn, R.O., Stefan, M.I., Bolton, J.R., 2000. The iodide/iodate actinometer in UV disinfection: characteristics and use in the determination of the fluence rate distribution in UV reactors. Procedings of the Water Quality Technology Conference, CDROM, Salt Lake City, UT, American Water Works Association, Denver, CO.
-
(2000)
Procedings of the Water Quality Technology Conference
-
-
Rahn, R.O.1
Stefan, M.I.2
Bolton, J.R.3
-
13
-
-
0034861690
-
Predicting the ultraviolet radiation distribution in a room with multilouvered germicidal fixtures
-
S. Rudnick Predicting the ultraviolet radiation distribution in a room with multilouvered germicidal fixtures AIHA J. 62 2001 434 445
-
(2001)
AIHA J.
, vol.62
, pp. 434-445
-
-
Rudnick, S.1
-
15
-
-
32644485960
-
Use of the iodide/iodate actinometer together with spherical cells for determination of the fluence rate distribution in UV reactors: Validation of the mathematical model
-
CDROM, International Ultraviolet Association, ON, Canada N0B 1E0.
-
Stefan, M.I., Rahn, R.O., Bolton, J.R., 2001. Use of the iodide/iodate actinometer together with spherical cells for determination of the fluence rate distribution in UV reactors: validation of the mathematical model. Proceedings of the First International Congress on Ultraviolet Technology, CDROM, International Ultraviolet Association, ON, Canada N0B 1E0.
-
(2001)
Proceedings of the First International Congress on Ultraviolet Technology
-
-
Stefan, M.I.1
Rahn, R.O.2
Bolton, J.R.3
|