메뉴 건너뛰기




Volumn 1, Issue , 2004, Pages 740-743

High frequency elastography for in-vivo study of the mechanichal behavior of skin

Author keywords

Elastography; High frequency ultrasound; Lateral displacement; Skin; Strain; Stretching

Indexed keywords

IMAGING TECHNIQUES; SCANNING; SCATTERING; STRAIN MEASUREMENT; STRESS ANALYSIS; STRETCHING; ULTRASONICS;

EID: 21644470578     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (12)
  • 1
    • 0036089542 scopus 로고    scopus 로고
    • Spatial variation of acoustic parameters in human skin: An in vitro study between 22 and 45 MHz
    • M. Lebertre, F. Ossant, L. Vaillant, S. Diridollou, and F. Patat, "Spatial Variation of Acoustic Parameters in Human Skin: an In Vitro Study Between 22 and 45 MHz," Ultrasound in Medicine and Biology, vol. 28, pp. 599-615, 2002.
    • (2002) Ultrasound in Medicine and Biology , vol.28 , pp. 599-615
    • Lebertre, M.1    Ossant, F.2    Vaillant, L.3    Diridollou, S.4    Patat, F.5
  • 2
    • 0019129751 scopus 로고
    • Mechanical properties and young modulus of human skin in-vivo
    • P. Agache, C. Monneur, J.L. Leveque, and J. d. Rigal, "Mechanical Properties and Young Modulus of Human Skin In-Vivo," Arch.Dermat.Res, vol. 269, pp. 221-232, 1980.
    • (1980) Arch.Dermat.Res , vol.269 , pp. 221-232
    • Agache, P.1    Monneur, C.2    Leveque, J.L.3    Rigal, J.D.4
  • 3
    • 0014836129 scopus 로고
    • A method for measuring human skin elasticity in-vivo with the observation of the effect of age, sex and pregnancy
    • R. Grahame, "A Method for Measuring Human Skin Elasticity In-vivo with the Observation of the Effect of Age, Sex and Pregnancy," Clin.Scien, vol. 39, pp. 223-238, 1970.
    • (1970) Clin.Scien , vol.39 , pp. 223-238
    • Grahame, R.1
  • 4
    • 0018947849 scopus 로고
    • Postopreative evaluation in plastic surgery using the bio-skin tension meter
    • T. Ohura, T. Sugihara, and K. Handa, "Postopreative Evaluation in Plastic Surgery Using the Bio-Skin Tension Meter," Annals of Plastic Surgery, vol. 5, pp. 74, 1980.
    • (1980) Annals of Plastic Surgery , vol.5 , pp. 74
    • Ohura, T.1    Sugihara, T.2    Handa, K.3
  • 6
    • 17044390600 scopus 로고    scopus 로고
    • A high frequency ultrasound elastography system for in-vivo skin elasticity imaging
    • M. Vogt, S. Scharenberg, R. Scharenberg, K. Hoffmann, P. Altmeyer, and H. Emert, "A High Frequency Ultrasound Elastography System for In-vivo Skin Elasticity Imaging," WCU, pp. 393-396, 2003.
    • (2003) WCU , pp. 393-396
    • Vogt, M.1    Scharenberg, S.2    Scharenberg, R.3    Hoffmann, K.4    Altmeyer, P.5    Emert, H.6
  • 7
    • 21644486730 scopus 로고    scopus 로고
    • In-vivo human skin elastography: A preleminary study
    • Y. Mofid, F. Ossant, F. Khatyr, M. Limberis, and F. Patat, "In-vivo Human Skin Elastography: A Preleminary Study," WCU, pp. 205-208, 2003.
    • (2003) WCU , pp. 205-208
    • Mofid, Y.1    Ossant, F.2    Khatyr, F.3    Limberis, M.4    Patat, F.5
  • 8
    • 0035713310 scopus 로고    scopus 로고
    • Axial strain imaging of intravascular data results on polyvinyl alcohol cryogel phantoms and carotid artery
    • E. Brusseau, J. Fromageau, G. Finet, P. Delachartre, and D. Vray, "Axial Strain Imaging of Intravascular Data Results On Polyvinyl Alcohol Cryogel Phantoms and Carotid Artery," Ultrasound In Med& Biol, vol. 27, pp. 1631-1642, 2001.
    • (2001) Ultrasound in Med& Biol , vol.27 , pp. 1631-1642
    • Brusseau, E.1    Fromageau, J.2    Finet, G.3    Delachartre, P.4    Vray, D.5
  • 9
    • 0036821077 scopus 로고    scopus 로고
    • Elastographic imaging using staggered strain estimates
    • S. Srinivasan, J. Ophir, and S. K.Alam, "Elastographic Imaging Using Staggered Strain Estimates," Ultrasound Imaging, vol. 24, pp. 229-245, 2002.
    • (2002) Ultrasound Imaging , vol.24 , pp. 229-245
    • Srinivasan, S.1    Ophir, J.2    Alam, S.K.3
  • 10
    • 0031056017 scopus 로고    scopus 로고
    • Reduction of signal decorrelation from mechanical compression of tissues by stretching: Application to elastography
    • S. K.Alam and J. Ophir, "Reduction of Signal Decorrelation from Mechanical Compression Of tissues By Stretching: Application to Elastography," Ultrasound In Med & Biol. vol. 23, pp. 95-105, 1996.
    • (1996) Ultrasound in Med & Biol. , vol.23 , pp. 95-105
    • Alam, S.K.1    Ophir, J.2
  • 11
    • 0032191886 scopus 로고    scopus 로고
    • A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and poisson's ratios in tissues
    • E. Konofagou and J. Ophir, "A New Elastographic Method For Estimation and Imaging OF Lateral Displacements, Lateral Strains, Corrected Axial strains AND Poisson's Ratios in Tissues," Ultrasound in Medicine and Biology, vol. 24, pp. 1183-1199, 1998.
    • (1998) Ultrasound in Medicine and Biology , vol.24 , pp. 1183-1199
    • Konofagou, E.1    Ophir, J.2
  • 12
    • 0030461387 scopus 로고    scopus 로고
    • Noise reduction in elastograms using temporal stretching with multicompression averaging
    • J. O. T.Varghes, "Noise Reduction in Elastograms Using Temporal Stretching With Multicompression Averaging," Ultrasound In Med & Biol, vol. 22, pp. 1043-1052, 1996.
    • (1996) Ultrasound in Med & Biol , vol.22 , pp. 1043-1052
    • Varghes, J.O.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.