Volumn 18, Issue 103, 2005, Pages 207-211
|
Simultaneous densitometric determination of rifampicin and isoniazid by high-performance thin-layer chromatography
a a a |
Author keywords
Densitometry; Isoniazid; Pharmaceutical research; Quantitative analysis; Rifampicin
|
Indexed keywords
ACETIC ACID;
DENSITOMETERS;
SCANNING;
SILICA GEL;
THIN LAYER CHROMATOGRAPHY;
ULTRAVIOLET RADIATION;
DENSITOMETRIC SCANNING;
ISONIAZID;
MOBILE PHASES;
RIFAMPICIN;
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY;
ACETIC ACID;
ACETIC ACID ETHYL ESTER;
ACETONE;
ISONIAZID;
ISONIAZID PLUS RIFAMPICIN;
METHANOL;
RIFAMAZID;
RIFAMPICIN;
SILICA GEL;
ACCURACY;
ARTICLE;
CALIBRATION;
CONTROLLED STUDY;
CORRELATION COEFFICIENT;
DENSITOMETRY;
DRUG DETERMINATION;
DRUG SOLUTION;
HIGH PERFORMANCE THIN LAYER CHROMATOGRAPHY;
MATHEMATICAL COMPUTING;
QUANTITATIVE ANALYSIS;
RADIATION ABSORPTION;
REGRESSION ANALYSIS;
REPRODUCIBILITY;
SPECTRAL SENSITIVITY;
ULTRAVIOLET RADIATION;
|
EID: 21644462315
PISSN: 09334173
EISSN: None
Source Type: Journal
DOI: 10.1556/JPC.18.2005.3.7 Document Type: Article |
Times cited : (19)
|
References (29)
|