메뉴 건너뛰기




Volumn 1, Issue , 2004, Pages 453-456

High frequency ultrasound speckle flow imaging comparision with Doppler Optical Coherence Tomography (DOCT)

Author keywords

Decorrelation; High frequency ultrasound; Microcirculation; Ultrasound biomicroscopy; Volumetric Blood Flow

Indexed keywords

ALGORITHMS; BIOLOGICAL ORGANS; BLOOD; DISEASES; FLOW OF FLUIDS; MEDICAL IMAGING; MICROCIRCULATION; REAL TIME SYSTEMS; VISUALIZATION;

EID: 21644441928     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (14)

References (6)
  • 2
    • 0023670566 scopus 로고
    • Methods for estimation of statistical properties of envelopes of ultrasonic echoes from myocardium
    • KA Wear, RL Popp, "Methods for estimation of statistical properties of envelopes of ultrasonic echoes from myocardium", IEEE Trans. Med. Imag., vol. 6, pp. 281-291, 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.6 , pp. 281-291
    • Wear, K.A.1    Popp, R.L.2
  • 3
    • 0035057605 scopus 로고    scopus 로고
    • Volume flow measurement using Doppler and grey-scale decorrelation
    • JM Rubin, TA Tuthill, JB Fowlkes, "Volume flow measurement using Doppler and grey-scale decorrelation", Ultrasound in Med. & Biol., vol. 27(1), pp. 101-109, 2001.
    • (2001) Ultrasound in Med. & Biol. , vol.27 , Issue.1 , pp. 101-109
    • Rubin, J.M.1    Tuthill, T.A.2    Fowlkes, J.B.3
  • 4
    • 1042290601 scopus 로고    scopus 로고
    • High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I): System design, signal processing, and performance
    • VXD Yang, ML Gordon, B Qi, J Pekar, S Lo, E Seng-Vue, A Mot BC Wilson, IA Vitkin, "High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I): System design, signal processing, and performance", Opt. Express, vol., 11, pp. 794-809, 2003.
    • (2003) Opt. Express , vol.11 , pp. 794-809
    • Yang, V.X.D.1    Gordon, M.L.2    Qi, B.3    Pekar, J.4    Lo, S.5    Seng-Vue, E.6    Mot, A.7    Wilson, B.C.8    Vitkin, I.A.9
  • 5
    • 0346262462 scopus 로고    scopus 로고
    • High speed, wide velocity dynamic range Doppler optical coherence tomography (Part II): Imaging in vivo cardiac dynamics of Xenopus laevis
    • VXD Yang, ML Gordon, E Seng-Yue, S Lo, B Qi, J Pekar, A Mok, BC Wilson, IA Vitkin, "High speed, wide velocity dynamic range Doppler optical coherence tomography (Part II): Imaging in vivo cardiac dynamics of Xenopus laevis", Opt. Express, vol., 11, pp. 1650-1658, 2003.
    • (2003) Opt. Express , vol.11 , pp. 1650-1658
    • Yang, V.X.D.1    Gordon, M.L.2    Seng-Yue, E.3    Lo, S.4    Qi, B.5    Pekar, J.6    Mok, A.7    Wilson, B.C.8    Vitkin, I.A.9
  • 6
    • 0036401609 scopus 로고    scopus 로고
    • Ultrasound backscatter microscopy spectroscopy and optical coherence (Doppler) tomography for mechanism-specific monitoring of photodynamic therapy in vivo and in vitro
    • VXD Yang, GJ Gzarnota, IA Vitkin, M Kolios, MD Sherar, J de Boer, B Tromberg, BC Wilson, "Ultrasound backscatter microscopy spectroscopy and optical coherence (Doppler) tomography for mechanism-specific monitoring of photodynamic therapy in vivo and in vitro", IEEE Proc. SPIE vol., 4612, pp. 128-135, 2002.
    • (2002) IEEE Proc. SPIE , vol.4612 , pp. 128-135
    • Yang, V.X.D.1    Gzarnota, G.J.2    Vitkin, I.A.3    Kolios, M.4    Sherar, M.D.5    De Boer, J.6    Tromberg, B.7    Wilson, B.C.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.