메뉴 건너뛰기




Volumn 32, Issue 3, 2005, Pages

Research on the FPA imaging character based on microscanning

Author keywords

Aliasing; Fill factor; Focusing plane array imagery; Microscanning; Sampling averaging MTF

Indexed keywords

ANTI-ALIASING; DETECTORS; FOCUSING; NYQUIST DIAGRAMS; SCANNING; TRANSFER FUNCTIONS;

EID: 21444433199     PISSN: 10012400     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (7)
  • 1
    • 21444437591 scopus 로고    scopus 로고
    • Chinese source
  • 2
    • 0029771925 scopus 로고    scopus 로고
    • Realization of a fast microscanning device for infrared focal plane arrays
    • SPIE
    • Fortin J, Chevere P. Realization of a Fast Microscanning Device for Infrared Focal Plane Arrays[A]. SPIE, 2742[C]. [s.l]: SPIE, 1996. 185-196.
    • (1996) SPIE, 2742 , pp. 185-196
    • Fortin, J.1    Chevere, P.2
  • 3
    • 84978314425 scopus 로고
    • The effect of microscan operation on starring infrared sensor imagery
    • SPIE
    • Blommel F P, Peter D, Dennis N J. The Effect of Microscan Operation on Starring Infrared Sensor Imagery[A]. SPIE, 1540[C]. [s.l]: SPIE, 1991. 653-664.
    • (1991) SPIE, 1540 , pp. 653-664
    • Blommel, F.P.1    Peter, D.2    Dennis, N.J.3
  • 4
    • 0000194015 scopus 로고
    • Aliasing and blurring in microscanning imagery
    • SPIE
    • Watson E A, Muse R A, Blommel F P. Aliasing and Blurring in Microscanning Imagery[A]. SPIE, 1689 [C]. [s.l]: SPIE, 1992. 242-250.
    • (1992) SPIE, 1689 , pp. 242-250
    • Watson, E.A.1    Muse, R.A.2    Blommel, F.P.3
  • 5
    • 0032404988 scopus 로고    scopus 로고
    • Comparison of microscan model and optical prefiltering model for aliasing artifacts reduction in discrete imaging systems
    • Shanghai: SPIE
    • Zhang Haitao, Zhang Yong, Zhao Dazun. Comparison of Microscan Model and Optical Prefiltering Model for Aliasing Artifacts Reduction in Discrete Imaging Systems[A]. SPIE, 3553[C]. Shanghai: SPIE, 1998. 222-230.
    • (1998) SPIE, 3553 , pp. 222-230
    • Zhang, H.1    Zhang, Y.2    Zhao, D.3
  • 6
    • 21444440144 scopus 로고    scopus 로고
    • Chinese source
  • 7
    • 0032627511 scopus 로고    scopus 로고
    • Oversampling requirements for pixilated-imager systems
    • Hadar O, Boreman G D. Oversampling Requirements for Pixilated-imager Systems[J]. Optical Engineering, 1999, 38(5): 782-785.
    • (1999) Optical Engineering , vol.38 , Issue.5 , pp. 782-785
    • Hadar, O.1    Boreman, G.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.