메뉴 건너뛰기




Volumn 5345, Issue , 2004, Pages 35-42

Study of Cell Secretion Using MEMS-Based Arrays

Author keywords

BioMEMS; Cell Secretion; Electrochemical detection; Nanotechnology

Indexed keywords

BIOMEMS; CELL SECRETION; ELECTROCHEMICAL DETECTION; MICROARRAYS;

EID: 2142740403     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.524896     Document Type: Conference Paper
Times cited : (3)

References (6)
  • 1
    • 0035798162 scopus 로고    scopus 로고
    • Synaptotagmin modulation of fusion pore kinetics in regulated exocytosis of dense-core vesicles
    • Wang, C. T. et al. Synaptotagmin modulation of fusion pore kinetics in regulated exocytosis of dense-core vesicles. Science 294, 1111-1115 (2001).
    • (2001) Science , vol.294 , pp. 1111-1115
    • Wang, C.T.1
  • 2
    • 0033126053 scopus 로고    scopus 로고
    • High calcium concentrations shift the mode of exocytosis to the kiss-and-run mechanism
    • Ales, E. et al. High calcium concentrations shift the mode of exocytosis to the kiss-and-run mechanism. Nat Cell Biol 1, 40-44 (1999).
    • (1999) Nat Cell Biol , vol.1 , pp. 40-44
    • Ales, E.1
  • 3
    • 0000928887 scopus 로고
    • eds. Sakmann, B. & Neher, E. (Plenum Press, New York)
    • Chow, R. H. et al in Single Channel Recording (eds. Sakmann, B. & Neher, E.) 245-275 (Plenum Press, New York, 1995).
    • (1995) Single Channel Recording , pp. 245-275
    • Chow, R.H.1
  • 4
    • 0036405282 scopus 로고    scopus 로고
    • A novel microfabricated device to measure hormone/neurotransmitter release with millisecond temporal resolution
    • Gillis, K. D., Chen, P., Xu, B., Tokronova, N., Feng, X. & Castracane, J., A novel microfabricated device to measure hormone/ neurotransmitter release with millisecond temporal resolution. Proc. SPIE Vol. 4626 378-382 (2002).
    • (2002) Proc. SPIE , vol.4626 , pp. 378-382
    • Gillis, K.D.1    Chen, P.2    Xu, B.3    Tokronova, N.4    Feng, X.5    Castracane, J.6
  • 5
    • 0013000758 scopus 로고    scopus 로고
    • Amperometric detection of quantal catecholamine secretion from individual cells on micromachined silicon chips
    • Chen, P., Xu, B., Tokranova, N., Feng, X., Castracane, J. & Gillis K. D., Amperometric detection of quantal catecholamine secretion from individual cells on micromachined silicon chips. Anal. Chem. Vol. 75 518-524 (2003).
    • (2003) Anal. Chem. , vol.75 , pp. 518-524
    • Chen, P.1    Xu, B.2    Tokranova, N.3    Feng, X.4    Castracane, J.5    Gillis, K.D.6
  • 6
    • 0031714494 scopus 로고    scopus 로고
    • Constitutive secretion of exogenous neurotransmitter by nonneuronal cells: Implications for neuronal secretion
    • Chang S., et al. Constitutive secretion of exogenous neurotransmitter by nonneuronal cells: implications for neuronal secretion. Biophysical Journal Vol. 75 1354-1364 (1998).
    • (1998) Biophysical Journal , vol.75 , pp. 1354-1364
    • Chang, S.1