Volumn 218, Issue 1, 2004, Pages 27-34

Analysis of elastohydrodynamic lubrication in McKee-Farrar metal-on-metal hip joint replacement

Author keywords

Elastohydrodynamic lubrication; Finite element; Metal on metal hip prosthesis

Indexed keywords

BONE CEMENT; DISEASES; ELASTIC MODULI; ELASTICITY; ELASTOHYDRODYNAMIC LUBRICATION; FINITE DIFFERENCE METHOD; FINITE ELEMENT METHOD; IMPLANTS (SURGICAL); JOINTS (ANATOMY); POISSON RATIO; PRESSURE DISTRIBUTION; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS;

EID: 2142696598     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/095441104322807721     Document Type: Conference Paper
Times cited : (9)

References (27)
  • 3
    • 0030625634 scopus 로고    scopus 로고
    • Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements
    • Semlitsch, M. and Willert, H. G. Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1997, 211(H1), 73-88.
    • (1997) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.211 , Issue.H1 , pp. 73-88
    • Semlitsch, M.1    Willert, H.G.2
  • 4
    • 0015052277 scopus 로고
    • The tribology (friction, lubrication and wear) of all-metal artificial hip joints
    • Walker, P. S. and Gold, B. L. The tribology (friction, lubrication and wear) of all-metal artificial hip joints. Wear, 1971, 17, 285-299.
    • (1971) Wear , vol.17 , pp. 285-299
    • Walker, P.S.1    Gold, B.L.2
  • 7
    • 0035045395 scopus 로고    scopus 로고
    • Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
    • Firkins, P. J., Tipper, J. L., Saadatzadeti, M. R., Ingham, E., Stone, M. H., Farrar, R. and Fisher, J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Bio-med. Mater. Engng, 2001, 11, 143-157.
    • (2001) Bio-med. Mater. Engng , vol.11 , pp. 143-157
    • Firkins, P.J.1    Tipper, J.L.2    Saadatzadeti, M.R.3    Ingham, E.4    Stone, M.H.5    Farrar, R.6    Fisher, J.7
  • 8
    • 0029817370 scopus 로고    scopus 로고
    • Cobalt and chromium concentrations in patients with metal on metal total hip replacements
    • Jacobs, J. et al. Cobalt and chromium concentrations in patients with metal on metal total hip replacements. Clin. Orthop. Related Res., 1996, 329S, 256-263.
    • (1996) Clin. Orthop. Related Res. , vol.329 S , pp. 256-263
    • Jacobs, J.1
  • 9
    • 0036380582 scopus 로고    scopus 로고
    • Ion release in patients with metal-on-metal hip bearings in total joint replacement: A comparison with metal-on-polyethylene bearings
    • Savarino, L. et al. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J. Biomed. Mater. Res., 2002, 63(5), 467-474.
    • (2002) J. Biomed. Mater. Res. , vol.63 , Issue.5 , pp. 467-474
    • Savarino, L.1
  • 10
    • 0346037224 scopus 로고    scopus 로고
    • Serum and urine metal levels in patients with metal-on-metal surface arthroplasty
    • Skipor, A. K. et al. Serum and urine metal levels in patients with metal-on-metal surface arthroplasty. J Mater. Sci.: Mater. Medicine, 2002, 13(12), 1227-1234.
    • (2002) J Mater. Sci.: Mater. Medicine , vol.13 , Issue.12 , pp. 1227-1234
    • Skipor, A.K.1
  • 11
    • 0037290075 scopus 로고    scopus 로고
    • TNF-alpha secretion and macrophage mortality induced by cobalt and chromium ions in vitro. Qualitative analysis of apoptosis
    • Catelas, I. et al. TNF-alpha secretion and macrophage mortality induced by cobalt and chromium ions in vitro. Qualitative analysis of apoptosis. Biomaterials, 2003, 24(3), 383-391.
    • (2003) Biomaterials , vol.24 , Issue.3 , pp. 383-391
    • Catelas, I.1
  • 12
    • 0037290074 scopus 로고    scopus 로고
    • Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro
    • Germain, M.A. et al. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials, 2003, 24(3), 469-479.
    • (2003) Biomaterials , vol.24 , Issue.3 , pp. 469-479
    • Germain, M.A.1
  • 13
    • 0037233869 scopus 로고    scopus 로고
    • Metal-on-metal versus polyethylene in hip arthroplasty: A randomized clinical trial
    • MacDonald, S. J. et al. Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin. Orthop. Related Res., 2003, 406, 282-296.
    • (2003) Clin. Orthop. Related Res. , vol.406 , pp. 282-296
    • MacDonald, S.J.1
  • 14
    • 0030627631 scopus 로고    scopus 로고
    • Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus
    • Jin, Z. M., Dowson, D. and Fisher, J. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1997, 211, 247-256.
    • (1997) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.211 , pp. 247-256
    • Jin, Z.M.1    Dowson, D.2    Fisher, J.3
  • 16
    • 0035229408 scopus 로고    scopus 로고
    • The effect of femoral head diameter upon the lubrication and wear of metal-on-metal total hip replacements
    • Smith, S. L., Dowson, D. and Goldsmith, A. A. The effect of femoral head diameter upon the lubrication and wear of metal-on-metal total hip replacements. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215, 161-170.
    • (2001) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.215 , pp. 161-170
    • Smith, S.L.1    Dowson, D.2    Goldsmith, A.A.3
  • 17
    • 0035065646 scopus 로고    scopus 로고
    • Influence of simulator kinematics on the wear of metal-on-metal hip prostheses
    • Firkins, P. J. et al. Influence of simulator kinematics on the wear of metal-on-metal hip prostheses. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215(H2), 119-121.
    • (2001) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.215 , Issue.H2 , pp. 119-121
    • Firkins, P.J.1
  • 18
    • 0029810740 scopus 로고    scopus 로고
    • Metal on metal surface replacement of the hip. Experience of the McMinn prosthesis
    • McMinn, D., Treacy, R., Lin, K. and Pynsent, P. Metal on metal surface replacement of the hip. Experience of the McMinn prosthesis. Clin. Orthop., 1996, 329 (Suppl.), S89-98.
    • (1996) Clin. Orthop. , vol.329 , Issue.SUPPL.
    • McMinn, D.1    Treacy, R.2    Lin, K.3    Pynsent, P.4
  • 19
    • 0020068498 scopus 로고
    • An axisymmetric model of acetabular components in total hip arthroplasty
    • Pedersen, D. R., Crowninshield, R. D., Brand, R. A. and Johnson, R. C. An axisymmetric model of acetabular components in total hip arthroplasty. J. Biomechanics, 1982, 15(4), 305-325.
    • (1982) J. Biomechanics , vol.15 , Issue.4 , pp. 305-325
    • Pedersen, D.R.1    Crowninshield, R.D.2    Brand, R.A.3    Johnson, R.C.4
  • 20
    • 0029347550 scopus 로고
    • Development and validation of a 3-dimensional finite-element model of the pelvic bone
    • Dalstra, M., Huiskes, R. and Vanerning, L. Development and validation of a 3-dimensional finite-element model of the pelvic bone. Trans. ASME, J. Biomech. Engng, 1995, 117(3), 272-278.
    • (1995) Trans. ASME, J. Biomech. Engng , vol.117 , Issue.3 , pp. 272-278
    • Dalstra, M.1    Huiskes, R.2    Vanerning, L.3
  • 22
    • 0035736351 scopus 로고    scopus 로고
    • Elastohydrodynamic lubrication of metal-on-metal hip prosthesis under steady-state entraining motion
    • Jagatia, M. and Jin, Z. M. Elastohydrodynamic lubrication of metal-on-metal hip prosthesis under steady-state entraining motion. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215, 531-541.
    • (2001) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.215 , pp. 531-541
    • Jagatia, M.1    Jin, Z.M.2
  • 23
    • 0017865921 scopus 로고
    • Elastohydrodynamic lubrication of elliptical contacts for materials of low elastic modulus: 1. Fully flooded conjunction
    • Hamrock, B. J. and Dowson, D. Elastohydrodynamic lubrication of elliptical contacts for materials of low elastic modulus: 1. Fully flooded conjunction. Trans ASME, J. Lubric. Technol., 1978, 100, 236-245.
    • (1978) Trans ASME, J. Lubric. Technol. , vol.100 , pp. 236-245
    • Hamrock, B.J.1    Dowson, D.2
  • 24
    • 0001035035 scopus 로고
    • Hydrodynamic theory for lubrication during rolling
    • Kapiza, P. L. Hydrodynamic theory for lubrication during rolling. Zh. Tekh. Fiz., 1955, 25(4), 747-762.
    • (1955) Zh. Tekh. Fiz. , vol.25 , Issue.4 , pp. 747-762
    • Kapiza, P.L.1
  • 27
    • 0012164284 scopus 로고    scopus 로고
    • Elastohydrodynamic lubrication and wear of metal-on-metal hip implants
    • Eds C. Rieker et al., Montreux, Switzerland, 5-7 October (Hans Huber, Bern, Switzerland)
    • Medley, J. B., Bobyn, J. D., Krygier, J. J., Chan, F. W., Tanzer, M. and Roter, G. E. Elastohydrodynamic lubrication and wear of metal-on-metal hip implants. In World Tribology Forum in Arthroplasty, Eds C. Rieker et al., Montreux, Switzerland, 5-7 October 2000 (Hans Huber, Bern, Switzerland), pp. 125-136.
    • (2000) World Tribology Forum in Arthroplasty , pp. 125-136
    • Medley, J.B.1    Bobyn, J.D.2    Krygier, J.J.3    Chan, F.W.4    Tanzer, M.5    Roter, G.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.