메뉴 건너뛰기




Volumn 30, Issue 3, 2005, Pages 274-280

Does iodine concentration affect the diagnostic efficacy of biphasic spiral CT in patients with hepatocellular carcinoma?

Author keywords

Hepatocellular carcinoma; High concentration iodinated contrast medium; Iomeprol; Liver imaging; Liver tumor staging; Multiphase spiral computed tomography

Indexed keywords

IODINE; IOMEPROL;

EID: 21244503171     PISSN: 09428925     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00261-004-0233-0     Document Type: Article
Times cited : (29)

References (25)
  • 1
    • 0031936748 scopus 로고    scopus 로고
    • Imaging of the liver with helical CT: A survey of scanning techniques
    • PM Silverman L Kohan I Ducic 1998 Imaging of the liver with helical CT: a survey of scanning techniques AJR 170 149 152
    • (1998) AJR , vol.170 , pp. 149-152
    • Silverman, P.M.1    Kohan, L.2    Ducic, I.3
  • 2
    • 0028937598 scopus 로고
    • Dual-phase helical CT of the liver: Value of arterial phase scans in the detection of small (≤ 1.5 cm) malignant hepatic neoplasms
    • MD Hollett RB Jeffrey Jr M Nino-Murcia 1995 Dual-phase helical CT of the liver: value of arterial phase scans in the detection of small (≤ 1.5 cm) malignant hepatic neoplasms AJR 164 879 884
    • (1995) AJR , vol.164 , pp. 879-884
    • Hollett, M.D.1    Jeffrey Jr., R.B.2    Nino-Murcia, M.3
  • 3
    • 0029988097 scopus 로고    scopus 로고
    • Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT
    • RL Baron JH Oliver Jr GD Dodd Jr 1996 Hepatocellular carcinoma: evaluation with biphasic, contrast-enhanced, helical CT Radiology 199 505 511
    • (1996) Radiology , vol.199 , pp. 505-511
    • Baron, R.L.1    Oliver Jr., J.H.2    Dodd Jr., G.D.3
  • 4
    • 0029790034 scopus 로고    scopus 로고
    • Helical biphasic contrast-enhancement CT of the liver: Technique, indications, interpretation and pitfalls
    • JH Oliver III RL Baron 1996 Helical biphasic contrast-enhancement CT of the liver: technique, indications, interpretation and pitfalls Radiology 201 1 14
    • (1996) Radiology , vol.201 , pp. 1-14
    • Oliver III, J.H.1    Baron, R.L.2
  • 5
    • 0031932016 scopus 로고    scopus 로고
    • Frequency and effects of extravasation of ionic and non-ionic contrast media during rapid bolus injection
    • MP Federle PJ Chang S Confer B Ozgun 1998 Frequency and effects of extravasation of ionic and non-ionic contrast media during rapid bolus injection Radiology 206 637 640
    • (1998) Radiology , vol.206 , pp. 637-640
    • Federle, M.P.1    Chang, P.J.2    Confer, S.3    Ozgun, B.4
  • 6
    • 0029257120 scopus 로고
    • Prediction of the time to peak hepatic enhancement to optimize contrast-enhanced spiral CT
    • T Irie S Suzuki T Yamauchi S Kusano 1995 Prediction of the time to peak hepatic enhancement to optimize contrast-enhanced spiral CT Acta Radiol 36 154 158
    • (1995) Acta Radiol , vol.36 , pp. 154-158
    • Irie, T.1    Suzuki, S.2    Yamauchi, T.3    Kusano, S.4
  • 7
    • 0029926355 scopus 로고    scopus 로고
    • Effect of rate of contrast medium injection on hepatic enhancement at CT
    • PA Garcia VM Bonaldi PM Bret 1996 Effect of rate of contrast medium injection on hepatic enhancement at CT Radiology 199 185 189
    • (1996) Radiology , vol.199 , pp. 185-189
    • Garcia, P.A.1    Bonaldi, V.M.2    Bret, P.M.3
  • 8
    • 0028434138 scopus 로고
    • The chemistry of iomeprol and physico-chemical properties of its aqueous solutions and pharmaceutical formulations
    • A Gallotti F Uggeri A Favilla 1994 The chemistry of iomeprol and physico-chemical properties of its aqueous solutions and pharmaceutical formulations Eur J Radiol 18(suppl 1) S1 S12
    • (1994) Eur J Radiol , vol.181
    • Gallotti, A.1    Uggeri, F.2    Favilla, A.3
  • 9
    • 0034077651 scopus 로고    scopus 로고
    • Iomeprol: A review of its use as a contrast medium
    • M Dooley B Jarvis 2000 Iomeprol: a review of its use as a contrast medium Drugs 59 1169 1186
    • (2000) Drugs , vol.59 , pp. 1169-1186
    • Dooley, M.1    Jarvis, B.2
  • 13
    • 0032755930 scopus 로고    scopus 로고
    • Effective contrast use in CT angiography and dual-phase hepatic CT performed with a subsecond scanner
    • W Luboldt J Straub M Seemann 1999 Effective contrast use in CT angiography and dual-phase hepatic CT performed with a subsecond scanner Invest Radiol 34 751 760
    • (1999) Invest Radiol , vol.34 , pp. 751-760
    • Luboldt, W.1    Straub, J.2    Seemann, M.3
  • 14
    • 0038331239 scopus 로고    scopus 로고
    • Optimizing contrast use in multislice CT
    • Silverman PM (2002) Optimizing contrast use in multislice CT. Appl Radiol suppl to March 2002: 10-12
    • (2002) Appl Radiol , Issue.SUPPL. TO MARCH 2002 , pp. 10-12
    • Silverman, P.M.1
  • 15
    • 0036720964 scopus 로고    scopus 로고
    • Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multidetector-row helical CT
    • K Awai K Takada H Onishi S Hori 2002 Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multidetector-row helical CT Radiology 224 757 763
    • (2002) Radiology , vol.224 , pp. 757-763
    • Awai, K.1    Takada, K.2    Onishi, H.3    Hori, S.4
  • 16
    • 0343517484 scopus 로고    scopus 로고
    • Detection of focal liver lesions at biphasic spiral CT: Randomized, double-blind study of the effect of iodine concentration in contrast materials
    • EL Hänninen TJ Vogl R Felfe 2000 Detection of focal liver lesions at biphasic spiral CT: randomized, double-blind study of the effect of iodine concentration in contrast materials Radiology 216 403 409
    • (2000) Radiology , vol.216 , pp. 403-409
    • Hänninen, E.L.1    Vogl, T.J.2    Felfe, R.3
  • 17
    • 0037655570 scopus 로고    scopus 로고
    • High-concentration contrast delivers in hepatic imaging
    • Nelson RC (2002) High-concentration contrast delivers in hepatic imaging. Appl Radiol suppl to March 2002: 13-16
    • (2002) Appl Radiol , Issue.SUPPL. TO MARCH 2002 , pp. 13-16
    • Nelson, R.C.1
  • 18
    • 0027960919 scopus 로고
    • Hepatic CT enhancement. Part I. Alterations in the volume of contrast material within the same patients
    • TP Chambers RL Baron RM Lush 1994 Hepatic CT enhancement. Part I. Alterations in the volume of contrast material within the same patients Radiology 193 513 517
    • (1994) Radiology , vol.193 , pp. 513-517
    • Chambers, T.P.1    Baron, R.L.2    Lush, R.M.3
  • 19
    • 0027987144 scopus 로고
    • Hepatic enhancement. Part CT II. Alterations in contrast material volume and rate of injection within the same patients
    • TP Chambers RL Baron RM Lush 1994 Hepatic enhancement. Part CT II. Alterations in contrast material volume and rate of injection within the same patients Radiology 193 518 522
    • (1994) Radiology , vol.193 , pp. 518-522
    • Chambers, T.P.1    Baron, R.L.2    Lush, R.M.3
  • 20
    • 0029152751 scopus 로고
    • Hepatic helical CT: Effect of reduction of iodine dose of intravenous contrast material on hepatic contrast enhancement
    • PC Freeny JC Gardner G von Ingersleben 1995 Hepatic helical CT: effect of reduction of iodine dose of intravenous contrast material on hepatic contrast enhancement Radiology 197 89 93
    • (1995) Radiology , vol.197 , pp. 89-93
    • Freeny, P.C.1    Gardner, J.C.2    Von Ingersleben, G.3
  • 21
    • 0029870406 scopus 로고    scopus 로고
    • Spiral-CT of the liver: Optimizing contrast medium administration and examination technique
    • TJ Vogl N Hidajat RJ Schröder 1996 Spiral-CT of the liver: optimizing contrast medium administration and examination technique Aktuelle Radiol 6 7 12
    • (1996) Aktuelle Radiol , vol.6 , pp. 7-12
    • Vogl, T.J.1    Hidajat, N.2    Schröder, R.J.3
  • 22
    • 0028362884 scopus 로고
    • Contrast-enhanced spiral CT of the liver: Effect of different amounts and injection rates of contrast material on early contrast enhancement
    • WC Small RC Nelson ME Bernardino LT Brummer 1994 Contrast-enhanced spiral CT of the liver: effect of different amounts and injection rates of contrast material on early contrast enhancement AJR 163 87 92
    • (1994) AJR , vol.163 , pp. 87-92
    • Small, W.C.1    Nelson, R.C.2    Bernardino, M.E.3    Brummer, L.T.4
  • 23
    • 0036550807 scopus 로고    scopus 로고
    • Multidetector helical CT of the liver for tumor detection and characterization
    • AF Kopp M Heuschmid CD Claussen 2002 Multidetector helical CT of the liver for tumor detection and characterization Eur Radiol 12 745 752
    • (2002) Eur Radiol , vol.12 , pp. 745-752
    • Kopp, A.F.1    Heuschmid, M.2    Claussen, C.D.3
  • 24
    • 0033851891 scopus 로고    scopus 로고
    • Multiphase hepatic CT with a multidetector CT scanner
    • D Foley T Mallisee MD Hohenwalter 2000 Multiphase hepatic CT with a multidetector CT scanner AJR 175 679 685
    • (2000) AJR , vol.175 , pp. 679-685
    • Foley, D.1    Mallisee, T.2    Hohenwalter, M.D.3
  • 25
    • 0037294281 scopus 로고    scopus 로고
    • Hepatocellular carcinoma: Detection with a triple phase multidetector row helical CT in patients with chronic hepatitis
    • A Laghi R Iannaccone P Rossi 2003 Hepatocellular carcinoma: detection with a triple phase multidetector row helical CT in patients with chronic hepatitis Radiology 226 543 549
    • (2003) Radiology , vol.226 , pp. 543-549
    • Laghi, A.1    Iannaccone, R.2    Rossi, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.