메뉴 건너뛰기




Volumn 52, Issue 1, 2005, Pages 81-89

Current practices and problems in the reuse of single-use devices in Japan

Author keywords

Disposable surgical instrument; Endoscopic surgery; Reuse of SUDs; Single use devices; SUDs

Indexed keywords

ARTICLE; DISPOSABLE EQUIPMENT; ENDOSCOPE; EQUIPMENT; HOSPITAL EQUIPMENT; HUMAN; INSTRUMENT STERILIZATION; JAPAN; QUESTIONNAIRE; RECYCLING; STATISTICS;

EID: 21244483013     PISSN: 13428810     EISSN: 13428810     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (13)

References (16)
  • 1
    • 58149207374 scopus 로고
    • Laparoscopic instruments, Patient care, cost issues
    • Reichert M. Laparoscopic instruments, Patient care, cost issues. AORN Journal 1993;57:637-55
    • (1993) AORN Journal , vol.57 , pp. 637-55
    • Reichert, M.1
  • 2
    • 0029335658 scopus 로고
    • Estimating the true costs of disposable and reusable instruments
    • Mancuso R Jr, Bickham MJ, Estimating the true costs of disposable and reusable instruments. AORN Journal 1995;62:39-48
    • (1995) AORN Journal , vol.62 , pp. 39-48
    • Mancuso R., Jr.1    Bickham, M.J.2
  • 3
    • 67049126596 scopus 로고    scopus 로고
    • EUCOMED Patients in danger:The reuse of single-use medical devices in Europe
    • EUCOMED (2001). Patients in danger:The reuse of single-use medical devices in Europe.
    • (2001)
  • 5
    • 67049120275 scopus 로고    scopus 로고
    • Re-use of single-use devices in Australia
    • Harrigan P. Re-use of single-use devices in Australia. Lancet 1996;347:1476
    • (1996) Lancet , vol.347 , pp. 1476
    • Harrigan, P.1
  • 7
    • 0032558872 scopus 로고    scopus 로고
    • Patient safety and the reuse of single-use medical items
    • Nye P, Wilson J. Patient safety and the reuse of single-use medical items. Brit J Nurs 1998;7:1167-8
    • (1998) Brit J Nurs , vol.7 , pp. 1167-8
    • Nye, P.1    Wilson, J.2
  • 8
    • 0029561790 scopus 로고
    • Reuse of disposable laparoscopic instruments:a study of related surgical complications
    • DesCoteaux JG, Poulin EC, Lortie M et al. Reuse of disposable laparoscopic instruments:a study of related surgical complications. Canad J Surg 1995;38:497-500
    • (1995) Canad J Surg , vol.38 , pp. 497-500
    • DesCoteaux, J.G.1    Poulin, E.C.2    Lortie, M.3
  • 9
    • 84860172556 scopus 로고    scopus 로고
    • Enforcement Priorities for Single-Use Devices Reprocessed by Third Parties and Hospitals
    • Enforcement Priorities for Single-Use Devices Reprocessed by Third Parties and Hospitals. U.S. Food and Drug Administration. 2000 (http://www.fda.gov/cdrh/comp/guidance/1168.pdf)
    • (2000) U.S. Food and Drug Administration
  • 10
    • 5344252358 scopus 로고    scopus 로고
    • Impact of FDA policy change on the reuse of single-use medical devices in Michigan hospitals
    • Alfa MJ, Castillo J. Impact of FDA policy change on the reuse of single-use medical devices in Michigan hospitals. Am J Infect Control 2004;32:337-41
    • (2004) Am J Infect Control , vol.32 , pp. 337-41
    • Alfa, M.J.1    Castillo, J.2
  • 11
    • 0033019625 scopus 로고    scopus 로고
    • Reuse of disposable sphincterotomes for diagnostic and therapeutic ERCP: a one-year prospective study
    • Kozarek RA, Raltz SL, Ball TJ et al. Reuse of disposable sphincterotomes for diagnostic and therapeutic ERCP: a one-year prospective study. Gastrointest Endosc. 1999;49:39-42
    • (1999) Gastrointest Endosc. , vol.49 , pp. 39-42
    • Kozarek, R.A.1    Raltz, S.L.2    Ball, T.J.3
  • 12
    • 0036305702 scopus 로고    scopus 로고
    • Specific hygiene issues relating to reprocessing and reuse of single-use devices for laparoscopic surgery
    • Roth K, Heeg P, Reich R. Specific hygiene issues relating to reprocessing and reuse of single-use devices for laparoscopic surgery. Surg Endosc. 2002;16:1091-7.
    • (2002) Surg Endosc. , vol.16 , pp. 1091-7
    • Roth, K.1    Heeg, P.2    Reich, R.3
  • 13
    • 0037662959 scopus 로고    scopus 로고
    • Inadequacy of manual cleaning for reprocessing single-use, triple-lumen sphincterotomes:Simulateduse testing comparing manual with automated cleaning methods
    • Alfa MJ, Nemes R. Inadequacy of manual cleaning for reprocessing single-use, triple-lumen sphincterotomes:Simulateduse testing comparing manual with automated cleaning methods. Am J Infect Control 2003;31:193-207.
    • (2003) Am J Infect Control , vol.31 , pp. 193-207
    • Alfa, M.J.1    Nemes, R.2
  • 14
    • 0032919955 scopus 로고    scopus 로고
    • In vitro evaluation of integrity and sterilization of single-use argon beam plasma coagulation probes
    • Roach SK, Kozarek RA, Ralts SL et al. In vitro evaluation of integrity and sterilization of single-use argon beam plasma coagulation probes. Am J Gastroenterology 1999;94:139-43.
    • (1999) Am J Gastroenterology , vol.94 , pp. 139-43
    • Roach, S.K.1    Kozarek, R.A.2    Ralts, S.L.3
  • 15
    • 2642691672 scopus 로고    scopus 로고
    • A prospective comparison of the costs of reusable and limited reuse laparoscopic instruments
    • DesCoteaux JG, Blackmore K, Parsons L. A prospective comparison of the costs of reusable and limited reuse laparoscopic instruments. Canad J Surg 1998;41:136-41.
    • (1998) Canad J Surg , vol.41 , pp. 136-41
    • DesCoteaux, J.G.1    Blackmore, K.2    Parsons, L.3
  • 16
    • 0028822561 scopus 로고
    • Disposable versus reusable laparoscopic cholecystectomy instruments-an audit of cost
    • Wilkinson JM, Hosie KB, Johnson AG. Disposable versus reusable laparoscopic cholecystectomy instruments-an audit of cost. Minimally Invasive Therapy 1994;4:211-4.
    • (1994) Minimally Invasive Therapy , vol.4 , pp. 211-4
    • Wilkinson, J.M.1    Hosie, K.B.2    Johnson, A.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.