Volumn 91, Issue 10, 2003, Pages 1492-1502

Fast volume scanning approaches by x-ray-computed tomography

Author keywords

Computed tomography (CT); Dose; Multislice spiral CT (MSCT); Reconstruction algorithms; Spiral CT; X ray detectors

Indexed keywords

ALGORITHMS; HEALTH CARE; IMAGE QUALITY; IMAGE RECONSTRUCTION; MEDICAL IMAGING; OPTICAL RESOLVING POWER; SCANNING; X RAY ANALYSIS;

EID: 21244477910     PISSN: 00189219     EISSN: None     Source Type: Journal    
DOI: 10.1109/JPROC.2003.817880     Document Type: Conference Paper
Times cited : (12)

References (69)
  • 1
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single breath-hold technique, continuous transport, and scanner rotation
    • W. A. Kalender, W. Seissler, E. Klotz, and P. Vock, "Spiral volumetric CT with single breath-hold technique, continuous transport, and scanner rotation," Radiology, vol. 176, pp. 181-183, 1990.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 2
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • C. R. Crawford and K. F. King, "Computed tomography scanning with simultaneous patient translation," Med. Phys., vol. 17, no. 6, pp. 967-982, 1990.
    • (1990) Med. Phys. , vol.17 , Issue.6 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 4
    • 0028298099 scopus 로고
    • A comparison of conventional and spiral CT: An experimental study on the detection of spherical lesions
    • W. A. Kalender, A. Polacin, and C. Süß, "A comparison of conventional and spiral CT: An experimental study on the detection of spherical lesions," J. Comput. Assist. Tomography, vol. 18, pp. 167-176, 1994.
    • (1994) J. Comput. Assist. Tomography , vol.18 , pp. 167-176
    • Kalender, W.A.1    Polacin, A.2    Süß, C.3
  • 5
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • A. Polacin, W. A. Kalender, and G. Marchal, "Evaluation of section sensitivity profiles and image noise in spiral CT," Radiology, vol. 185, pp. 29-35, 1992.
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 6
    • 0025722120 scopus 로고
    • Phosphors for X-ray detectors in computed tomography
    • W. Rossner and B. C. Grabmaier, "Phosphors for X-ray detectors in computed tomography," J. Lumin., vol. 48-49, pp. 29-36, 1991.
    • (1991) J. Lumin. , vol.48-49 , pp. 29-36
    • Rossner, W.1    Grabmaier, B.C.2
  • 8
    • 0034257872 scopus 로고    scopus 로고
    • Direct comparison of a xenon and a solid-state CT detector system: Measurements under working conditions
    • Sept.
    • T. O. J. Fuchs, M. Kachelrieß, and W. A. Kalender, "Direct comparison of a xenon and a solid-state CT detector system: Measurements under working conditions," IEEE Trans. Med. Imag., vol. 19, pp. 941-948, Sept. 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 941-948
    • Fuchs, T.O.J.1    Kachelrieß, M.2    Kalender, W.A.3
  • 11
    • 0026795603 scopus 로고
    • Highly stable solid-state X-ray detector array
    • T. Takahashi, M. Nakagawa, M. Yoshida, and H. Takeuchi, "Highly stable solid-state X-ray detector array," Med. Phys., vol. 19, no. 5, pp.1161-1166, 1992.
    • (1992) Med. Phys. , vol.19 , Issue.5 , pp. 1161-1166
    • Takahashi, T.1    Nakagawa, M.2    Yoshida, M.3    Takeuchi, H.4
  • 13
    • 0020764170 scopus 로고
    • An inversion formula for cone-beam reconstruction
    • H. K. Tuy, "An inversion formula for cone-beam reconstruction," SIAM J. Appl Math., vol. 43, no. 3, pp. 546-552, 1983.
    • (1983) SIAM J. Appl Math. , vol.43 , Issue.3 , pp. 546-552
    • Tuy, H.K.1
  • 14
    • 0026873904 scopus 로고
    • Implementation, investigation, and improvement of a novel cone-beam reconstruction method
    • Feb.
    • B. D. Smith and J. Chen, "Implementation, investigation, and improvement of a novel cone-beam reconstruction method," IEEE Trans. Med. Imag., vol. 11, pp. 260-266, Feb. 1992.
    • (1992) IEEE Trans. Med. Imag. , vol.11 , pp. 260-266
    • Smith, B.D.1    Chen, J.2
  • 16
    • 0027663276 scopus 로고
    • A note on Smith's reconstruction algorithm for cone-beam tomography
    • Mar.
    • M. Défrise, R. Clack, and R. M. Leahy, "A note on Smith's reconstruction algorithm for cone-beam tomography," IEEE Trans. Med. Imag., vol. 12, pp. 622-623, Mar. 1993.
    • (1993) IEEE Trans. Med. Imag. , vol.12 , pp. 622-623
    • Défrise, M.1    Clack, R.2    Leahy, R.M.3
  • 17
    • 0028392621 scopus 로고
    • A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection
    • Jan.
    • M. Defrise and R. Clack, "A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection," IEEE Trans. Med. Imag., vol. 13, pp. 186-195, Jan. 1994.
    • (1994) IEEE Trans. Med. Imag. , vol.13 , pp. 186-195
    • Defrise, M.1    Clack, R.2
  • 18
    • 0028300221 scopus 로고
    • Implementation of Tuy's cone-beam inversion formula
    • G. L. Zeng, R. Clack, and G. T. Gullberg, "Implementation of Tuy's cone-beam inversion formula," Phys. Med. Biol., vol. 39, pp. 493-507, 1994.
    • (1994) Phys. Med. Biol. , vol.39 , pp. 493-507
    • Zeng, G.L.1    Clack, R.2    Gullberg, G.T.3
  • 19
    • 0030215028 scopus 로고    scopus 로고
    • Implementations, comparisons and an investigation of heuristic techniques for cone-beam tomography
    • Apr.
    • B. D. Smith, "Implementations, comparisons and an investigation of heuristic techniques for cone-beam tomography," IEEE Trans. Med. Imag., vol. 15, pp. 519-531, Apr. 1996.
    • (1996) IEEE Trans. Med. Imag. , vol.15 , pp. 519-531
    • Smith, B.D.1
  • 21
    • 0034263454 scopus 로고    scopus 로고
    • Multi-row detector and cone-beam spiral/helical CT
    • Sept.
    • [21 ] G. Wang, C. R. Crawford, and W. A. Kalender, "Multi-row detector and cone-beam spiral/helical CT," IEEE Trans. Med. Imag., vol. 19, pp. 817-821, Sept. 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 817-821
    • Wang, G.1    Crawford, C.R.2    Kalender, W.A.3
  • 22
    • 0034188460 scopus 로고    scopus 로고
    • Exact radon rebinning algorithm for the long-object problem in helical cone-beam CT
    • May
    • S. Schaller, F. Noo, F. Sauer, K. C. Tam, G. Lauritsch, and T. Flohr, "Exact radon rebinning algorithm for the long-object problem in helical cone-beam CT," IEEE Trans. Med. Imag., vol. 19, pp. 361-375, May 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 361-375
    • Schaller, S.1    Noo, F.2    Sauer, F.3    Tam, K.C.4    Lauritsch, G.5    Flohr, T.6
  • 23
    • 0034178285 scopus 로고    scopus 로고
    • Exact spiral + circles scan region-of-Interest cone-beam reconstruction via backprojection
    • May
    • K. C. Tam, G. Lauritsch, K. Sourbelle, F. Sauer, and B. Ladendorf, "Exact spiral + circles scan region-of-Interest cone-beam reconstruction via backprojection," IEEE Trans. Med. Imag., vol. 19, pp. 376-383, May 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 376-383
    • Tam, K.C.1    Lauritsch, G.2    Sourbelle, K.3    Sauer, F.4    Ladendorf, B.5
  • 24
    • 0034187651 scopus 로고    scopus 로고
    • Multislice helical CT: Image temporal resolution
    • May
    • H. Hu, T. Pan, and Y. Shen, "Multislice helical CT: Image temporal resolution," IEEE Trans. Med. Imag., vol. 19, pp. 384-390, May 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 384-390
    • Hu, H.1    Pan, T.2    Shen, Y.3
  • 25
    • 0034178299 scopus 로고    scopus 로고
    • Enhanced 3D-reconstruction algorithm for C-arm systems suitable for interventional procedures
    • May
    • K. Wiesent, K. Barth, N. Navab, P. Durlak, T. Brunner, O. Schuetz, and W. Seissler, "Enhanced 3D-reconstruction algorithm for C-arm systems suitable for interventional procedures," IEEE Trans. Med. Imag., vol. 19, pp. 391-403, May 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 391-403
    • Wiesent, K.1    Barth, K.2    Navab, N.3    Durlak, P.4    Brunner, T.5    Schuetz, O.6    Seissler, W.7
  • 27
    • 0034257869 scopus 로고    scopus 로고
    • Quasiexact filtered backprojection algorithm for long-object problem in helical cone-beam tomography
    • Sept.
    • H. Kudo, F. Noo, and M. Deefrise, "Quasiexact filtered backprojection algorithm for long-object problem in helical cone-beam tomography," IEEE Trans. Med. Imag., vol. 19, pp. 902-921, Sept. 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 902-921
    • Kudo, H.1    Noo, F.2    Deefrise, M.3
  • 28
    • 0034257867 scopus 로고    scopus 로고
    • Feldkamp-type cone-beam tomography in the wavelet framework
    • Sept.
    • S. Zhao and G. Wang, "Feldkamp-type cone-beam tomography in the wavelet framework," IEEE Trans. Med. Imag., vol. 19, pp. 922-929, Sept. 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 922-929
    • Zhao, S.1    Wang, G.2
  • 29
    • 0031971976 scopus 로고    scopus 로고
    • Fast and stable cone-beam filtered backprojection method for nonplanar orbits
    • H. Kudo and T. Saito, "Fast and stable cone-beam filtered backprojection method for nonplanar orbits," Phys. Med. Biol., vol. 43, pp. 747-760, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 747-760
    • Kudo, H.1    Saito, T.2
  • 30
    • 0031961188 scopus 로고    scopus 로고
    • Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam projections
    • G. L. Zeng and G. T. Gullberg, "Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam projections," Phys. Med. Biol., vol. 43, pp. 811-821, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 811-821
    • Zeng, G.L.1    Gullberg, G.T.2
  • 31
    • 0031961358 scopus 로고    scopus 로고
    • High-helical-pitch, cone-beam computed tomography
    • M. D. Silver, "High-helical-pitch, cone-beam computed tomography," Phys. Med. Biol., vol. 43, pp. 847-855, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 847-855
    • Silver, M.D.1
  • 32
    • 0031961518 scopus 로고    scopus 로고
    • Exact cone-beam CT with a spiral scan
    • K. C. Tam, S. Samarasekera, and F. Sauer, "Exact cone-beam CT with a spiral scan," Phys. Med. Biol., vol. 43, pp. 1015-1024, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1015-1024
    • Tam, K.C.1    Samarasekera, S.2    Sauer, F.3
  • 33
    • 0031695422 scopus 로고    scopus 로고
    • Cone-beam filtered-backprojection algorithm for truncated helical data
    • H. Kudo, F. Noo, and M. Defrise, "Cone-beam filtered-backprojection algorithm for truncated helical data," Phys. Med. Biol., vol. 43, pp. 2885-2909, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2885-2909
    • Kudo, H.1    Noo, F.2    Defrise, M.3
  • 34
    • 0037036595 scopus 로고    scopus 로고
    • Analysis of an exact inversion algorithm for spiral cone-beam CT
    • A. Katsevich, "Analysis of an exact inversion algorithm for spiral cone-beam CT," Phys. Med. Biol., vol. 47, pp. 2583-2598, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2583-2598
    • Katsevich, A.1
  • 35
    • 0037036597 scopus 로고    scopus 로고
    • Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model
    • P. Grangeat, A. Koenig, T. Rodet, and S. Bonnet, "Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model," Phys. Med. Biol., vol. 47, pp. 2611-2626, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2611-2626
    • Grangeat, P.1    Koenig, A.2    Rodet, T.3    Bonnet, S.4
  • 36
    • 0037036653 scopus 로고    scopus 로고
    • Filtering point spread function in backprojection cone-beam CT and its applications in long-object imaging
    • K. C. Tam, G. Lauritsch, and K. Sourbelle, "Filtering point spread function in backprojection cone-beam CT and its applications in long-object imaging," Phys. Med. Biol., vol. 47, pp. 2685-2704, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2685-2704
    • Tam, K.C.1    Lauritsch, G.2    Sourbelle, K.3
  • 38
    • 0002018761 scopus 로고    scopus 로고
    • Mathematical framework of 3D reconstruction via the first derivative of the radon transform
    • Berlin, Germany: Springer-Verlag, 1991, Lecture Notes in Mathematics
    • _, "Mathematical framework of 3D reconstruction via the first derivative of the radon transform," in Mathematical Methods in Tomography. Berlin, Germany: Springer-Verlag, 1991, Lecture Notes in Mathematics, pp. 66-97.
    • Mathematical Methods in Tomography , pp. 66-97
  • 39
    • 0028397603 scopus 로고
    • Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits
    • Jan.
    • H. Kudo and T. Saito, "Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits," IEEE Trans. Med. Imag., vol. 13, pp. 196-211, Jan. 1994.
    • (1994) IEEE Trans. Med. Imag. , vol.13 , pp. 196-211
    • Kudo, H.1    Saito, T.2
  • 41
    • 0033701105 scopus 로고    scopus 로고
    • Exact local regions-of-interest reconstruction in spiral cone-beam filtered-backprojection CT: Theory
    • K. C. Tam, "Exact local regions-of-interest reconstruction in spiral cone-beam filtered-backprojection CT: Theory," in Proc. SPIE Medical Imaging Conf., vol. 3979, 2000, pp. 506-519.
    • (2000) Proc. SPIE Medical Imaging Conf. , vol.3979 , pp. 506-519
    • Tam, K.C.1
  • 42
    • 0034064498 scopus 로고    scopus 로고
    • A solution to the long-object problem helical cone-beam tomography
    • M. Defrise, F. Noo, and H. Kudo, "A solution to the long-object problem helical cone-beam tomography," Phys. Med. Biol., vol. 45, pp. 623-643, 2000.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 623-643
    • Defrise, M.1    Noo, F.2    Kudo, H.3
  • 44
    • 0033690570 scopus 로고    scopus 로고
    • A two-pass algorithm for cone-beam reconstruction
    • J. Hsieh, "A two-pass algorithm for cone-beam reconstruction," in Proc. SPIE Medical Imaging Conf., vol. 3979, 2000, pp. 533-540.
    • (2000) Proc. SPIE Medical Imaging Conf. , vol.3979 , pp. 533-540
    • Hsieh, J.1
  • 45
    • 58749097611 scopus 로고    scopus 로고
    • New, efficient fourier-reconstruction method for approximate image reconstruction in spiral cone-beam CT at small cone-angles
    • S. Schaller, T. Flohr, and P. Steffen, "New, efficient fourier-reconstruction method for approximate image reconstruction in spiral cone-beam CT at small cone-angles," in Proc. SPIE Medical Imaging Conf., vol. 3032, 1997, pp. 213-224.
    • (1997) Proc. SPIE Medical Imaging Conf. , vol.3032 , pp. 213-224
    • Schaller, S.1    Flohr, T.2    Steffen, P.3
  • 46
    • 0343340400 scopus 로고    scopus 로고
    • 3D cone-beam CT reconstruction for circular trajectories
    • M. Grass, T. Köhler, and R. Proska, "3D cone-beam CT reconstruction for circular trajectories," Phys. Med. Biol., vol. 45, pp. 329-347, 2000.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 329-347
    • Grass, M.1    Köhler, T.2    Proska, R.3
  • 47
    • 0026544832 scopus 로고
    • Cone-beam tomography with circular, elliptical and spiral orbits
    • X. Yan and R. M. Leahy, "Cone-beam tomography with circular, elliptical and spiral orbits," Phys. Med. Biol., vol. 37, pp. 493-506, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 493-506
    • Yan, X.1    Leahy, R.M.2
  • 49
    • 0033686510 scopus 로고    scopus 로고
    • Performance of approximate cone-beam reconstruction in multi-slice computed tomography
    • H. Bruder, M. Kachelrieß, and S. Schaller, "Performance of approximate cone-beam reconstruction in multi-slice computed tomography," in Proc. SPIE Medical Imaging Conf., vol. 3979, 2000.
    • (2000) Proc. SPIE Medical Imaging Conf. , vol.3979
    • Bruder, H.1    Kachelrieß, M.2    Schaller, S.3
  • 50
    • 0031739421 scopus 로고    scopus 로고
    • Helical CT reconstruction with longitudinal filtration
    • H. Hu and Y. Shen, "Helical CT reconstruction with longitudinal filtration," Med. Phys., vol. 25, no. 11, pp. 2130-2138, 1998.
    • (1998) Med. Phys. , vol.25 , Issue.11 , pp. 2130-2138
    • Hu, H.1    Shen, Y.2
  • 51
    • 0031956821 scopus 로고    scopus 로고
    • Algorithm for image reconstruction in multi-slice helical CT
    • K. Taguchi and H. Aradate, "Algorithm for image reconstruction in multi-slice helical CT," Med. Phys., vol. 25, no. 4, pp. 550-561, 1998.
    • (1998) Med. Phys. , vol.25 , Issue.4 , pp. 550-561
    • Taguchi, K.1    Aradate, H.2
  • 52
    • 0036668839 scopus 로고    scopus 로고
    • Anti-aliasing weighting functions for single-slice helical CT
    • Aug.
    • P. J. La Riviere and X. C. Pan, "Anti-aliasing weighting functions for single-slice helical CT," IEEE Trans. Med. Imag., vol. 21, pp. 978-990, Aug. 2002.
    • (2002) IEEE Trans. Med. Imag. , vol.21 , pp. 978-990
    • La Riviere, P.J.1    Pan, X.C.2
  • 53
    • 0037036611 scopus 로고    scopus 로고
    • Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)
    • _, "Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)," Phys. Med. Biol., vol. 47, pp. 2797-2810, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2797-2810
  • 54
    • 0020030616 scopus 로고
    • Optimal short scan convolution reconstruction for fan-beam CT
    • D. L. Parker, "Optimal short scan convolution reconstruction for fan-beam CT," Med. Phys., vol. 9, pp. 254-257, 1982.
    • (1982) Med. Phys. , vol.9 , pp. 254-257
    • Parker, D.L.1
  • 55
    • 0032912554 scopus 로고    scopus 로고
    • Single-slice rebinning method for helical cone-beam CT
    • F. Noo, M. Defrise, and R. Clackdoyle, "Single-slice rebinning method for helical cone-beam CT," Phys. Med. Biol., vol. 44, pp. 561-570, 1999.
    • (1999) Phys. Med. Biol. , vol.44 , pp. 561-570
    • Noo, F.1    Defrise, M.2    Clackdoyle, R.3
  • 56
    • 0033999358 scopus 로고    scopus 로고
    • Advanced single-slice rebinning in cone-beam spiral CT
    • M. Kachelrieß, S. Schaller, and W. A. Kalender, "Advanced single-slice rebinning in cone-beam spiral CT," Med. Phys., vol. 27, no. 4, pp. 754-772, 2000.
    • (2000) Med. Phys. , vol.27 , Issue.4 , pp. 754-772
    • Kachelrieß, M.1    Schaller, S.2    Kalender, W.A.3
  • 57
    • 0034977516 scopus 로고    scopus 로고
    • Advanced single-slice rebinning for tilted spiral cone-beam CT
    • M. Kachelrieß, T. Fuchs, S. Schaller, and W. A. Kalender, "Advanced single-slice rebinning for tilted spiral cone-beam CT," Med. Phys., vol. 28, no. 6, pp. 1033-1041, 2001.
    • (2001) Med. Phys. , vol.28 , Issue.6 , pp. 1033-1041
    • Kachelrieß, M.1    Fuchs, T.2    Schaller, S.3    Kalender, W.A.4
  • 58
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering (MAP) for conventional and spiral single-slice, multi-slice and cone-beam CT
    • M. Kachelrieß, O. Watzke, and W. A. Kalender, "Generalized multi-dimensional adaptive filtering (MAP) for conventional and spiral single-slice, multi-slice and cone-beam CT," Med. Phys., vol. 28, no. 4, pp. 475-490, 2001.
    • (2001) Med. Phys. , vol.28 , Issue.4 , pp. 475-490
    • Kachelrieß, M.1    Watzke, O.2    Kalender, W.A.3
  • 60
    • 0032414773 scopus 로고    scopus 로고
    • ECG-correlated image reconstruction from sub-second spiral CT scans of the heart
    • M. Kachelrieß and W. A. Kalender, "ECG-correlated image reconstruction from sub-second spiral CT scans of the heart," Med. Phys., vol. 25, no. 12, pp. 2417-2431, 1998.
    • (1998) Med. Phys. , vol.25 , Issue.12 , pp. 2417-2431
    • Kachelrieß, M.1    Kalender, W.A.2
  • 61
    • 0033863629 scopus 로고    scopus 로고
    • ECG-correlated image reconstruction from sub-second mulit-slice spiral CT scans of the heart
    • M. Kachelrieß, S. Ulzheimer, and W. A. Kalender, "ECG-correlated image reconstruction from sub-second mulit-slice spiral CT scans of the heart," Med. Phys., vol. 27, no. 8, pp. 1881-1902, 2000.
    • (2000) Med. Phys. , vol.27 , Issue.8 , pp. 1881-1902
    • Kachelrieß, M.1    Ulzheimer, S.2    Kalender, W.A.3
  • 62
    • 0034257870 scopus 로고    scopus 로고
    • ECG-correlated imaging of the heart with sub-second multi-slice spiral CT
    • Sept.
    • _, "ECG-correlated imaging of the heart with sub-second multi-slice spiral CT," IEEE Trans. Med. Imag., vol. 19, pp. 888-901, Sept. 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 888-901
  • 63
    • 0035996436 scopus 로고    scopus 로고
    • Kymogram detection and kymogram-correlated image reconstruction from sub-second multi-slice and cone-beam spiral CT scans of the heart
    • M. Kachelrieß, W. Maxlmoser, D.-A. Sennst, and W. A. Kalender, "Kymogram detection and kymogram-correlated image reconstruction from sub-second multi-slice and cone-beam spiral CT scans of the heart," Med. Phys., vol. 29, no. 7, pp. 1489-1503, 2002.
    • (2002) Med. Phys. , vol.29 , Issue.7 , pp. 1489-1503
    • Kachelrieß, M.1    Maxlmoser, W.2    Sennst, D.-A.3    Kalender, W.A.4
  • 65
    • 0034764479 scopus 로고    scopus 로고
    • Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates
    • M. Karolczak, S. Schaller, K. Engelke, A. Lutz, U. Taubenreuther, K. Wiesent, and W. A. Kalender, "Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates," Med. Phys., vol. 26, no. 10, pp. 2050-2069, 2001.
    • (2001) Med. Phys. , vol.26 , Issue.10 , pp. 2050-2069
    • Karolczak, M.1    Schaller, S.2    Engelke, K.3    Lutz, A.4    Taubenreuther, U.5    Wiesent, K.6    Kalender, W.A.7
  • 66
    • 0033849841 scopus 로고    scopus 로고
    • Optimization of X-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography)
    • J. H. Siewerdsen and D. A. Jaffray, "Optimization of X-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography)," Med. Phys., vol. 27, no. 8, pp. 1903-1914, 2000.
    • (2000) Med. Phys. , vol.27 , Issue.8 , pp. 1903-1914
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 67
    • 0035110308 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of X-ray scatter
    • _, "Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of X-ray scatter," Med. Phys., vol. 28, no. 2, pp. 220-231, 2001.
    • (2001) Med. Phys. , vol.28 , Issue.2
  • 68
    • 0034086714 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    • D. A. Jaffray and J. H. Siewerdsen, "Cone-beam computed tomography with a flat-panel imager: Initial performance characterization," Med. Phys., vol. 27, no. 7, pp. 1311-1323, 2000.
    • (2000) Med. Phys. , vol.27 , Issue.7 , pp. 1311-1323
    • Jaffray, D.A.1    Siewerdsen, J.H.2
  • 69
    • 21244482766 scopus 로고    scopus 로고
    • 40 × 30 cm flat panel imager for angiography, R&F, and cone-beam CT applications
    • R. E. Colbeth et al., "40 × 30 cm flat panel imager for angiography, R&F, and cone-beam CT applications," in Proc. SPIE Medical Imaging Conf., 2001, pp. 4320-4354.
    • (2001) Proc. SPIE Medical Imaging Conf. , pp. 4320-4354
    • Colbeth, R.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.