Volumn 8, Issue 1, 2005, Pages 1-12

History of artificial organs in Japan

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL BLOOD; BIOMATERIAL; FIBRINOLYTIC AGENT; HEPARIN; RUBBER;

EID: 21244456917     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-004-0283-7     Document Type: Article
Times cited : (2)

References (26)
  • 3
    • 21244436330 scopus 로고
    • Artificial kidney utilizing dog's lung
    • S Kimoto 1959 Artificial kidney utilizing dog's lung Trans ASAIO 5 15 22
    • (1959) Trans ASAIO , vol.5 , pp. 15-22
    • Kimoto, S.1
  • 4
    • 0001187866 scopus 로고
    • The artificial liver: Experiments and clinical applications
    • S Kimoto 1959 The artificial liver: experiments and clinical applications Trans ASAIO 5 102
    • (1959) Trans ASAIO , vol.5 , pp. 102
    • Kimoto, S.1
  • 5
    • 21244486227 scopus 로고
    • Theoretical studies concerning quantitative analysis on artificial internal organs
    • S Watanabe 1959 Theoretical studies concerning quantitative analysis on artificial internal organs Trans ASAIO 5 113 119
    • (1959) Trans ASAIO , vol.5 , pp. 113-119
    • Watanabe, S.1
  • 6
    • 0005474356 scopus 로고
    • Artificial heart incorporated in the chest
    • K Atsumi 1963 Artificial heart incorporated in the chest Trans ASAIO 9 292 297
    • (1963) Trans ASAIO , vol.9 , pp. 292-297
    • Atsumi, K.1
  • 7
    • 0343896568 scopus 로고
    • Application of specially cross-linked natural rubber for artificial internal organs
    • K Atsumi 1963 Application of specially cross-linked natural rubber for artificial internal organs Trans ASAIO 9 324 331
    • (1963) Trans ASAIO , vol.9 , pp. 324-331
    • Atsumi, K.1
  • 8
    • 21244456796 scopus 로고
    • Study on the implantable artificial kidney: Development of an intestinal substitution for renal tubular reabsorption
    • O Otsubo 1980 Study on the implantable artificial kidney: development of an intestinal substitution for renal tubular reabsorption Trans ASAIO 9 58
    • (1980) Trans ASAIO , vol.9 , pp. 58
    • Otsubo, O.1
  • 9
    • 21244467100 scopus 로고
    • A new method for plasmapheresis using cellulose acetate hollow fiber as a plasma separator
    • N Inoue Z Yamazaki 1979 A new method for plasmapheresis using cellulose acetate hollow fiber as a plasma separator Trans ASAIO 3 267 271
    • (1979) Trans ASAIO , vol.3 , pp. 267-271
    • Inoue, N.1    Yamazaki, Z.2
  • 10
    • 18044377258 scopus 로고
    • New artificial liver support system (plasma perfusion detoxication) for hepatic coma
    • Z Yamazaki 1977 New artificial liver support system (plasma perfusion detoxication) for hepatic coma Proc ISAO 1 273 278
    • (1977) Proc ISAO , vol.1 , pp. 273-278
    • Yamazaki, Z.1
  • 11
    • 0019251269 scopus 로고
    • Double filtration plasmapheresis
    • T Agishi I Kaneko 1980 Double filtration plasmapheresis Trans ASAIO 26 406 411
    • (1980) Trans ASAIO , vol.26 , pp. 406-411
    • Agishi, T.1    Kaneko, I.2
  • 12
    • 21244448749 scopus 로고
    • Attachment of polymyxin B sulphate to polystyrene fiber
    • K Hanasawa M Kodama 1984 Attachment of polymyxin B sulphate to polystyrene fiber Ther Plasmaph 4 171 175
    • (1984) Ther Plasmaph , vol.4 , pp. 171-175
    • Hanasawa, K.1    Kodama, M.2
  • 13
    • 21244465870 scopus 로고
    • Thermoelectric heat exchanger for extracorporeal circulation
    • Yamazaki Z, et al. Thermoelectric heat exchanger for extracorporeal circulation. Digest of 6th I.C.M.E&B.E. 1965;579-580
    • (1965) Digest of 6th I.C.M.E&B.E. , pp. 579-580
    • Yamazaki, Z.1
  • 14
    • 0001849765 scopus 로고
    • Studies on porous polytetrafluoroethylene as a vascular prosthesis
    • 1
    • H Matsumoto 1972 Studies on porous polytetrafluoroethylene as a vascular prosthesis Artif Organs 1 1 44 47
    • (1972) Artif Organs , vol.1 , pp. 44-47
    • Matsumoto, H.1
  • 15
    • 0014542216 scopus 로고
    • Clinical experience with a new type of valve replacement. a cageless discoid type of prosthesis named the SAM valve
    • 4
    • T Arai 1969 Clinical experience with a new type of valve replacement. A cageless discoid type of prosthesis named the SAM valve Int J Med Sci 5 4 889 892
    • (1969) Int J Med Sci , vol.5 , pp. 889-892
    • Arai, T.1
  • 16
    • 0020252293 scopus 로고
    • Artificial liver: The concept and working hypothesis of hybrid organs from 25-year-old anecdote to the 21st century model
    • Hybrid artificial organs
    • M Hori Hybrid artificial organs 1982 Artificial liver: the concept and working hypothesis of hybrid organs from 25-year-old anecdote to the 21st century model Trans ASAIO 28 639
    • (1982) Trans ASAIO , vol.28 , pp. 639
    • Hori, M.1
  • 17
    • 21244455560 scopus 로고
    • A new method of treatment for acute hepatic insufficiency on extracorporeal metabolism
    • J Mikami M Mito 1961 A new method of treatment for acute hepatic insufficiency on extracorporeal metabolism Acta Hematol Jpn 2 115 117
    • (1961) Acta Hematol Jpn , vol.2 , pp. 115-117
    • Mikami, J.1    Mito, M.2
  • 18
    • 0031274139 scopus 로고    scopus 로고
    • Tissue engineering aspects of the development of bio-artificial livers
    • 6
    • N Ohshima 1997 Tissue engineering aspects of the development of bio-artificial livers J Chin Inst Chem Eng 28 6 441 453
    • (1997) J Chin Inst Chem Eng , vol.28 , pp. 441-453
    • Ohshima, N.1
  • 19
    • 0020402631 scopus 로고
    • Wearable-type artificial endocrine pancreas with needle glucose sensor
    • M Shichiri 1982 Wearable-type artificial endocrine pancreas with needle glucose sensor Lancet 2 1129 1131
    • (1982) Lancet , vol.2 , pp. 1129-1131
    • Shichiri, M.1
  • 20
    • 15544369912 scopus 로고
    • Preparation conditions of human hemoglobin vesicles covered with lipid membrane
    • S Takeoka Tsuchida 1993 Preparation conditions of human hemoglobin vesicles covered with lipid membrane Artif Organs Today 3 129 136
    • (1993) Artif Organs Today , vol.3 , pp. 129-136
    • Takeoka, S.1    Tsuchida2
  • 22
    • 0010699072 scopus 로고
    • Molecular design of block and graft copolymers having the ability to suppress platelet adhesion
    • T Okano 1981 Molecular design of block and graft copolymers having the ability to suppress platelet adhesion Artif Organs 5 468 470
    • (1981) Artif Organs , vol.5 , pp. 468-470
    • Okano, T.1
  • 23
    • 0027054983 scopus 로고
    • Regulation of differentiation and proliferation of rat hepatocytes by lactose-carrying polystyrene
    • K Kobayashi T Akaike 1992 Regulation of differentiation and proliferation of rat hepatocytes by lactose-carrying polystyrene Artif Organs 16 564 567
    • (1992) Artif Organs , vol.16 , pp. 564-567
    • Kobayashi, K.1    Akaike, T.2
  • 24
    • 0026591830 scopus 로고
    • Two-dimensional cell manipulation technology: An artificial neural circuit
    • T Matsuda T Sugawara 1992 Two-dimensional cell manipulation technology: an artificial neural circuit ASAIO J 38 243 247
    • (1992) ASAIO J , vol.38 , pp. 243-247
    • Matsuda, T.1    Sugawara, T.2
  • 25
    • 0016411880 scopus 로고
    • Hemodynamic analysis on prolonged survival cases (30 days and 20 days) of artificial total heart replacement
    • K Atsumi 1975 Hemodynamic analysis on prolonged survival cases (30 days and 20 days) of artificial total heart replacement Trans ASAIO 21 545 553
    • (1975) Trans ASAIO , vol.21 , pp. 545-553
    • Atsumi, K.1
  • 26
    • 0000586295 scopus 로고
    • Pathophysiological study of a total artificial heart in a goat that survived for 344 days
    • Nosé Y (ed) ISAO Press
    • Fujimasa I, Atsumi K, et al. Pathophysiological study of a total artificial heart in a goat that survived for 344 days. In: Nosé Y (ed) Progress in artificial organs. ISAO Press, 1985
    • (1985) Progress in Artificial Organs
    • Fujimasa, I.1    Atsumi, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.