메뉴 건너뛰기




Volumn 22, Issue 1, 2005, Pages 145-153

Repeatability of a novel technique for in vivo measurement of three-dimensional patellar tracking using magnetic resonance imaging

Author keywords

Kinematics; MRI; Patella; Patellofemoral joint; Repeatability; Tracking

Indexed keywords

ARTICLE; CONTROLLED STUDY; EXPERIMENTAL MODEL; HUMAN; KINEMATICS; KNEE FUNCTION; NUCLEAR MAGNETIC RESONANCE IMAGING; PATELLOFEMORAL JOINT; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING;

EID: 21244451965     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20360     Document Type: Article
Times cited : (34)

References (19)
  • 1
    • 0025800156 scopus 로고
    • The epidemiology of knee osteoarthritis: Results from the Framingham Osteoarthritis Study
    • Felson DT. The epidemiology of knee osteoarthritis: results from the Framingham Osteoarthritis Study. Semin Arthritis Rheum 1990; 20:42-50.
    • (1990) Semin Arthritis Rheum , vol.20 , pp. 42-50
    • Felson, D.T.1
  • 2
    • 0022528454 scopus 로고
    • Athletic injuries: Comparison by age, sport and gender
    • Dehaven KE, Litner DM. Athletic injuries: comparison by age, sport and gender. Am J Sports Med 1986;14:218-224.
    • (1986) Am J Sports Med , vol.14 , pp. 218-224
    • Dehaven, K.E.1    Litner, D.M.2
  • 3
    • 0033877730 scopus 로고    scopus 로고
    • The association between varus-valgus alignment and patellofemoral osteoarthritis
    • Elahi S, Cahue S, Felson DT, Engelman L, Sharma L. The association between varus-valgus alignment and patellofemoral osteoarthritis. Arthritis Rheum 2000;48:1874-1880.
    • (2000) Arthritis Rheum , vol.48 , pp. 1874-1880
    • Elahi, S.1    Cahue, S.2    Felson, D.T.3    Engelman, L.4    Sharma, L.5
  • 4
    • 0036638516 scopus 로고    scopus 로고
    • Increased knee joint loads during walking are present in subjects with knee osteoarthritis
    • Baliunas AJ, Hurwitz DE, Ryals AB, et al. Increased knee joint loads during walking are present in subjects with knee osteoarthritis. Osteoarthritis Cartilage 2002;10:573-579.
    • (2002) Osteoarthritis Cartilage , vol.10 , pp. 573-579
    • Baliunas, A.J.1    Hurwitz, D.E.2    Ryals, A.B.3
  • 5
  • 6
    • 0033118556 scopus 로고    scopus 로고
    • In vitro measurement of the tracking pattern of the human patella
    • Ahmed AM, Duncan NA, Tanzer M. In vitro measurement of the tracking pattern of the human patella. J Biomech Eng 1999;121: 222-228.
    • (1999) J Biomech Eng , vol.121 , pp. 222-228
    • Ahmed, A.M.1    Duncan, N.A.2    Tanzer, M.3
  • 7
    • 0025426762 scopus 로고
    • The three-dimensional tracking pattern of the human patella
    • van Kampen A, Huiskes R. The three-dimensional tracking pattern of the human patella. J Orthop Res 1990;8:372-382.
    • (1990) J Orthop Res , vol.8 , pp. 372-382
    • Kampen, A.1    Huiskes, R.2
  • 8
    • 0032611543 scopus 로고    scopus 로고
    • Kinematic CT and MR imaging of the patellofemoral joint
    • Muhle C, Brossman J, Heller M. Kinematic CT and MR imaging of the patellofemoral joint. Eur Radiol 1999;9:508-518.
    • (1999) Eur Radiol , vol.9 , pp. 508-518
    • Muhle, C.1    Brossman, J.2    Heller, M.3
  • 9
    • 0027313206 scopus 로고
    • Patellofemoral joint: Identification of abnormalities with active-movement, "unloaded" versus "loaded" kinematic MR imaging techniques
    • Shellock FG, Mink JH, Deutsch AL, Foo TK, Sullenberger P. Patellofemoral joint: identification of abnormalities with active-movement, "unloaded" versus "loaded" kinematic MR imaging techniques. Radiology 1993;188:575-578.
    • (1993) Radiology , vol.188 , pp. 575-578
    • Shellock, F.G.1    Mink, J.H.2    Deutsch, A.L.3    Foo, T.K.4    Sullenberger, P.5
  • 10
    • 12244296720 scopus 로고    scopus 로고
    • Precise 3D skeletal kinematics using fast phase contrast magnetic resonance imaging
    • Rebmann AJ, Sheehan FT. Precise 3D skeletal kinematics using fast phase contrast magnetic resonance imaging. J Magn Reson Imaging 2003;17:206-213.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 206-213
    • Rebmann, A.J.1    Sheehan, F.T.2
  • 11
    • 0032884930 scopus 로고    scopus 로고
    • Quantitative MR measures of three-dimensional patellar kinematics as a research and diagnostic tool
    • Sheehan FT, Drace JE. Quantitative MR measures of three-dimensional patellar kinematics as a research and diagnostic tool. Med Sci Sports Exerc 1999;31:1399-1405.
    • (1999) Med Sci Sports Exerc , vol.31 , pp. 1399-1405
    • Sheehan, F.T.1    Drace, J.E.2
  • 12
    • 0344505207 scopus 로고    scopus 로고
    • Using cine phase contrast MRI to non-invasively study in vivo knee dynamics
    • Sheehan FT, Zajac FE, Drace JE. Using cine phase contrast MRI to non-invasively study in vivo knee dynamics. J Biomech 1998;31: 21-26.
    • (1998) J Biomech , vol.31 , pp. 21-26
    • Sheehan, F.T.1    Zajac, F.E.2    Drace, J.E.3
  • 13
    • 0033406399 scopus 로고    scopus 로고
    • In vivo tracking of the human patella using cine phase contrast magnetic resonance imaging
    • Sheehan FT Zajac FE Drace JE. In vivo tracking of the human patella using cine phase contrast magnetic resonance imaging. J Biomech Eng 1999;121:650-656.
    • (1999) J Biomech Eng , vol.121 , pp. 650-656
    • Sheehan, F.T.1    Zajac, F.E.2    Drace, J.E.3
  • 14
    • 0345060366 scopus 로고    scopus 로고
    • Magnetic resonance imaging of patellofemoral kinematics with weight-bearing
    • Patel VV, Hall K, Ries M, et al. Magnetic resonance imaging of patellofemoral kinematics with weight-bearing. J Bone Joint Surg Am 2003;85:2419-2424.
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 2419-2424
    • Patel, V.V.1    Hall, K.2    Ries, M.3
  • 16
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Applications to the knee
    • Grood ES Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: applications to the knee. J Biomech 1994;105:136-144.
    • (1994) J Biomech , vol.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 17
    • 0242432353 scopus 로고    scopus 로고
    • The use of sequential MR image sets for determining tibiofemoral motion: Reliability of coordinate systems and accuracy of motion tracking algorithm
    • Lerner AL Tamez-Pena JG Houck JR et al. The use of sequential MR image sets for determining tibiofemoral motion: reliability of coordinate systems and accuracy of motion tracking algorithm. J Biomech Eng 2003;125:246-253.
    • (2003) J Biomech Eng , vol.125 , pp. 246-253
    • Lerner, A.L.1    Tamez-Pena, J.G.2    Houck, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.