-
1
-
-
0026833750
-
Literature survey on biomedical applications of thermography
-
Yang WJ, Yang PP. Literature survey on biomedical applications of thermography. Biomed Mater Eng 1992;2:7-18.
-
(1992)
Biomed Mater Eng
, vol.2
, pp. 7-18
-
-
Yang, W.J.1
Yang, P.P.2
-
3
-
-
0033393627
-
Is corneal temperature correlated with blood-flow velocity in the ophthalmic artery?
-
Gugleta K, Orgul S, Flammer J. Is corneal temperature correlated with blood-flow velocity in the ophthalmic artery? Curr Eye Res 1999;19:496-501.
-
(1999)
Curr Eye Res
, vol.19
, pp. 496-501
-
-
Gugleta, K.1
Orgul, S.2
Flammer, J.3
-
4
-
-
0033848585
-
The role of tear physiology in ocular surface temperature
-
Craig JP, Singh I, Tomlinson A, et al. The role of tear physiology in ocular surface temperature. Eye 2000;14:635-641.
-
(2000)
Eye
, vol.14
, pp. 635-641
-
-
Craig, J.P.1
Singh, I.2
Tomlinson, A.3
-
6
-
-
0032105509
-
Progress in the measurement of human body temperature
-
Ring EFJ. Progress in the measurement of human body temperature. IEEE Eng Med Biol Mag 1998;17:19-24.
-
(1998)
IEEE Eng Med Biol Mag
, vol.17
, pp. 19-24
-
-
Ring, E.F.J.1
-
8
-
-
32044469575
-
Physical aspects of infrared imaging
-
Webb S, ed. Bristol, Hilger
-
Jones CH. Physical aspects of infrared imaging. In: Webb S, ed. The Physics of Medical Imaging. Bristol, Hilger, 1988, pp 488-507.
-
(1988)
The Physics of Medical Imaging
, pp. 488-507
-
-
Jones, C.H.1
-
9
-
-
0000410495
-
The radiation of heat from the human body
-
Hardy J. The radiation of heat from the human body. J Clin Invest 1934;13:593-604,605-514,515-524.
-
(1934)
J Clin Invest
, vol.13
, pp. 593-604
-
-
Hardy, J.1
-
10
-
-
1542377086
-
Infra-red radiation thermometry in clinical practice
-
Williams KL, Williams FL, Handley RS. Infra-red radiation thermometry in clinical practice. Lancet 1960;2:958-959.
-
(1960)
Lancet
, vol.2
, pp. 958-959
-
-
Williams, K.L.1
Williams, F.L.2
Handley, R.S.3
-
11
-
-
0031870137
-
Infrared imaging: An emerging technology in medicine
-
Diakides NA. Infrared imaging: an emerging technology in medicine. IEEE Eng Med Biol Mag 1998;17:17-18.
-
(1998)
IEEE Eng Med Biol Mag
, vol.17
, pp. 17-18
-
-
Diakides, N.A.1
-
12
-
-
0032216616
-
A reappraisal of the use of infrared thermal image analysis in medicine
-
Jones BF. A reappraisal of the use of infrared thermal image analysis in medicine. IEEE Trans Med Imaging 1998;17:1019-1027.
-
(1998)
IEEE Trans Med Imaging
, vol.17
, pp. 1019-1027
-
-
Jones, B.F.1
-
13
-
-
0031845013
-
Investigating deep venous thrombosis with infrared imaging
-
Harding JR. Investigating deep venous thrombosis with infrared imaging. IEEE Eng Med Biol Mag 1998;17:43-46.
-
(1998)
IEEE Eng Med Biol Mag
, vol.17
, pp. 43-46
-
-
Harding, J.R.1
-
14
-
-
0032193567
-
Peripheral vascular reactions to smoking-profound vasoconstriction by atherosclerosis
-
Fushimi H, Kubo M, Inoue T, et al. Peripheral vascular reactions to smoking-profound vasoconstriction by atherosclerosis. Diabetes Res Clin Pract 1998;42:29-34.
-
(1998)
Diabetes Res Clin Pract
, vol.42
, pp. 29-34
-
-
Fushimi, H.1
Kubo, M.2
Inoue, T.3
-
15
-
-
0031869187
-
Infrared imaging of the breast: Initial reappraisal using high resolution digital technology in 100 successive cases of stage I and stage II breast cancer
-
Keyserling JR, Ahlgren PD, Yu E, et al. Infrared imaging of the breast: Initial reappraisal using high resolution digital technology in 100 successive cases of stage I and stage II breast cancer. Breast J 1998;4:245-251.
-
(1998)
Breast J
, vol.4
, pp. 245-251
-
-
Keyserling, J.R.1
Ahlgren, P.D.2
Yu, E.3
-
16
-
-
0032015778
-
Thermology and facial telethermography: Part II. Current and future clinical applications in dentistry
-
Gratt BM, Anbar M. Thermology and facial telethermography: Part II. Current and future clinical applications in dentistry. Dentomaxillofac Radiol 1998;27:68-74.
-
(1998)
Dentomaxillofac Radiol
, vol.27
, pp. 68-74
-
-
Gratt, B.M.1
Anbar, M.2
-
17
-
-
0031129486
-
Thermographic assessment of heat generated on the root surface during post space preparation
-
Hussey DL, Baigioni PA, McCullagh JJP, et al. Thermographic assessment of heat generated on the root surface during post space preparation. Int Endod J 1997;30:187-190.
-
(1997)
Int Endod J
, vol.30
, pp. 187-190
-
-
Hussey, D.L.1
Baigioni, P.A.2
McCullagh, J.J.P.3
-
18
-
-
0031129894
-
Thermographic assessment of root canal obturation using thermomechanical compaction
-
McCullagh JJP, Biagioni PA, Lamey PJ, et al. Thermographic assessment of root canal obturation using thermomechanical compaction. Int Endod J 1997;30:191-195.
-
(1997)
Int Endod J
, vol.30
, pp. 191-195
-
-
McCullagh, J.J.P.1
Biagioni, P.A.2
Lamey, P.J.3
-
19
-
-
0020050332
-
Thermographic evaluation of the human lacrimal drainage system
-
Raflo GT, Chart P, Hurwitz JJ. Thermographic evaluation of the human lacrimal drainage system. Ophthalmic Surg 1982;13:119-124.
-
(1982)
Ophthalmic Surg
, vol.13
, pp. 119-124
-
-
Raflo, G.T.1
Chart, P.2
Hurwitz, J.J.3
-
21
-
-
0034045510
-
Applying dynamic thermography in the diagnosis of breast cancer
-
Ohashi Y, Uchida I. Applying dynamic thermography in the diagnosis of breast cancer. IEEE Eng Med Biol Mag 2000;19:42-51.
-
(2000)
IEEE Eng Med Biol Mag
, vol.19
, pp. 42-51
-
-
Ohashi, Y.1
Uchida, I.2
-
22
-
-
84979133135
-
The temperature of the eye during the application of hot packs, and after milk injections
-
Holmberg A. The temperature of the eye during the application of hot packs, and after milk injections. Acta Ophthalmol (Copenh) 1952;30:347-364.
-
(1952)
Acta Ophthalmol (Copenh)
, vol.30
, pp. 347-364
-
-
Holmberg, A.1
-
23
-
-
0014273662
-
Measurement of corneal temperature
-
Mapstone R. Measurement of corneal temperature. Exp Eye Res 1968a;7:237-243.
-
(1968)
Exp Eye Res
, vol.7
, pp. 237-243
-
-
Mapstone, R.1
-
24
-
-
14844301005
-
Temperature changes of a human cornea and tears under a contact lens 1. The relaxed open eye, and the natural and forced closed eye conditions
-
Hill RM, Leighton AJ. Temperature changes of a human cornea and tears under a contact lens 1. The relaxed open eye, and the natural and forced closed eye conditions. Am J Optom Arch Am Acad 1965a;42:9-16.
-
(1965)
Am J Optom Arch Am Acad
, vol.42
, pp. 9-16
-
-
Hill, R.M.1
Leighton, A.J.2
-
25
-
-
84935312828
-
Temperature changes of human cornea and tears under a contact lens 2. Effects of intermediate lid apertures and gaze
-
Hill RM, Leighton AJ. Temperature changes of human cornea and tears under a contact lens 2. Effects of intermediate lid apertures and gaze. Am J Optom Arch Am Acad 1965b;42:71-77.
-
(1965)
Am J Optom Arch Am Acad
, vol.42
, pp. 71-77
-
-
Hill, R.M.1
Leighton, A.J.2
-
26
-
-
0012975563
-
Environmental temperature and the ocular temperature gradient
-
Schwartz B. Environmental temperature and the ocular temperature gradient. Arch Ophthalmol 1965;74:237-243.
-
(1965)
Arch Ophthalmol
, vol.74
, pp. 237-243
-
-
Schwartz, B.1
-
27
-
-
0014900373
-
Corneal sensitivity by low temperatures
-
Kolstad A. Corneal sensitivity by low temperatures. Acta Ophthalmol (Copenh) 1970;48:789-793.
-
(1970)
Acta Ophthalmol (Copenh)
, vol.48
, pp. 789-793
-
-
Kolstad, A.1
-
28
-
-
0015421511
-
Errors in eye tissue temperature measurements when using a metallic probe
-
Fatt I, Forester JF. Errors in eye tissue temperature measurements when using a metallic probe. Exp Eye Res 1972;14:270-276.
-
(1972)
Exp Eye Res
, vol.14
, pp. 270-276
-
-
Fatt, I.1
Forester, J.F.2
-
29
-
-
0015906415
-
Environmental influences on ocular temperature
-
Freeman RD, Fatt I. Environmental influences on ocular temperature. Invest Ophthalmol 1973;12:596-602.
-
(1973)
Invest Ophthalmol
, vol.12
, pp. 596-602
-
-
Freeman, R.D.1
Fatt, I.2
-
30
-
-
0015658688
-
A liquid-crystal contact lens device for measurement of corneal temperature
-
Kinn JB, Tell RA. A liquid-crystal contact lens device for measurement of corneal temperature. IEEE Trans Biomed Eng 1973;20:387-388.
-
(1973)
IEEE Trans Biomed Eng
, vol.20
, pp. 387-388
-
-
Kinn, J.B.1
Tell, R.A.2
-
31
-
-
0016781217
-
Corneal temperature in normal subjects and arterial occlusive disease
-
Horven I. Corneal temperature in normal subjects and arterial occlusive disease. Acta Ophthalmol (Copenh) 1975;53:863-874.
-
(1975)
Acta Ophthalmol (Copenh)
, vol.53
, pp. 863-874
-
-
Horven, I.1
-
32
-
-
0017724521
-
Temperature measurements in the eye
-
Rosenbluth RF, Fatt I. Temperature measurements in the eye. Exp Eye Res 1977;25:325-341.
-
(1977)
Exp Eye Res
, vol.25
, pp. 325-341
-
-
Rosenbluth, R.F.1
Fatt, I.2
-
33
-
-
0019971158
-
Choroidal blood flow. I. Ocular tissue temperature as a measure of flow
-
Auker CR, Parver LM, Doyle T, et al. Choroidal blood flow. I. Ocular tissue temperature as a measure of flow. Arch Ophthalmol 1982;100:1323-1326.
-
(1982)
Arch Ophthalmol
, vol.100
, pp. 1323-1326
-
-
Auker, C.R.1
Parver, L.M.2
Doyle, T.3
-
34
-
-
0021920433
-
The oxygen tension and temperature of the superior palpebral conjunctiva
-
Holden BA, Sweeney DF. The oxygen tension and temperature of the superior palpebral conjunctiva. Acta Ophthalmol (Copenh) 1985;63:100-103.
-
(1985)
Acta Ophthalmol (Copenh)
, vol.63
, pp. 100-103
-
-
Holden, B.A.1
Sweeney, D.F.2
-
35
-
-
0022499424
-
The presence of a contact lens induces a very small increase in the anterior corneal surface temperature
-
Martin D, Fatt I. The presence of a contact lens induces a very small increase in the anterior corneal surface temperature. Acta Ophthalmol (Copenh) 1986;64:512-518.
-
(1986)
Acta Ophthalmol (Copenh)
, vol.64
, pp. 512-518
-
-
Martin, D.1
Fatt, I.2
-
36
-
-
0014920359
-
Anterior segment hyperaemia and ischaemia
-
Mapstone R. Anterior segment hyperaemia and ischaemia. Trans Ophthalmol Soc UK 1970;90:329-335.
-
(1970)
Trans Ophthalmol Soc UK
, vol.90
, pp. 329-335
-
-
Mapstone, R.1
-
37
-
-
0014346407
-
Determinants of ocular temperature
-
Mapstone R. Determinants of ocular temperature. Br J Ophthalmol 1968b;52:729-741.
-
(1968)
Br J Ophthalmol
, vol.52
, pp. 729-741
-
-
Mapstone, R.1
-
38
-
-
0014654307
-
Thermometry and the eye
-
Mapstone R. Thermometry and the eye. Trans. Ophthalmol. Soc. UK 1969;88:693-699.
-
(1969)
Trans Ophthalmol Soc UK
, vol.88
, pp. 693-699
-
-
Mapstone, R.1
-
39
-
-
0014352844
-
Normal thermal patterns in cornea and periorbital skin
-
Mapstone R. Normal thermal patterns in cornea and periorbital skin. Br J Ophthalmol 1968c;52:818-827.
-
(1968)
Br J Ophthalmol
, vol.52
, pp. 818-827
-
-
Mapstone, R.1
-
40
-
-
0014384874
-
Corneal thermal patterns in anterior uveitis
-
Mapstone R. Corneal thermal patterns in anterior uveitis. Br J Ophthalmol 1968d;52:917-921.
-
(1968)
Br J Ophthalmol
, vol.52
, pp. 917-921
-
-
Mapstone, R.1
-
41
-
-
0014878387
-
Ocular thermography
-
Mapstone R. Ocular thermography. Br J Ophthalmol 1970;54:751-754.
-
(1970)
Br J Ophthalmol
, vol.54
, pp. 751-754
-
-
Mapstone, R.1
-
42
-
-
0027283750
-
Potential applications of ocular thermography
-
Morgan PB, Soh MP, Efron N, et al. Potential applications of ocular thermography. Optom Vis Sci 1993;70:568-576.
-
(1993)
Optom Vis Sci
, vol.70
, pp. 568-576
-
-
Morgan, P.B.1
Soh, M.P.2
Efron, N.3
-
44
-
-
0002154389
-
Ocular surface cooling in dry eye: A pilot study
-
Morgan PB, Tullo AB, Efron N. Ocular surface cooling in dry eye: A pilot study. J BCLA 1996;19:7-10.
-
(1996)
J BCLA
, vol.19
, pp. 7-10
-
-
Morgan, P.B.1
Tullo, A.B.2
Efron, N.3
-
46
-
-
0344258088
-
Experiments in thermometry of the anterior portion of the eye wearing a contact lens by means of infra-red thermometer
-
Hamano H, Minami S, Sugimori Y. Experiments in thermometry of the anterior portion of the eye wearing a contact lens by means of infra-red thermometer. Contacto 1969;13:12-22.
-
(1969)
Contacto
, vol.13
, pp. 12-22
-
-
Hamano, H.1
Minami, S.2
Sugimori, Y.3
-
47
-
-
0002701545
-
Temperature of a contact lens on the eye
-
Fatt I, Chaston J. Temperature of a contact lens on the eye. Int Contact Lens Clinic 1980;7:195-198.
-
(1980)
Int Contact Lens Clinic
, vol.7
, pp. 195-198
-
-
Fatt, I.1
Chaston, J.2
-
48
-
-
0031014744
-
Near infrared absorption in the human eye media
-
van den Berg TJTP, Spekreijse H. Near infrared absorption in the human eye media. Vision Res 1997;37:249-253.
-
(1997)
Vision Res
, vol.37
, pp. 249-253
-
-
Van Den Berg, T.J.T.P.1
Spekreijse, H.2
-
49
-
-
0026650519
-
Study of human precorneal tear film thickness and structure using laser interferometry
-
Prydal JI, Artal P, Woon H, et al. Study of human precorneal tear film thickness and structure using laser interferometry. Invest Ophthalmol Vis Sci 1992;33:2006-2011.
-
(1992)
Invest Ophthalmol Vis Sci
, vol.33
, pp. 2006-2011
-
-
Prydal, J.I.1
Artal, P.2
Woon, H.3
-
50
-
-
0014906026
-
Thermography in the diagnosis of diseases of the eye and the appraisal of therapeutic effects. A preliminary report
-
Wachtmeister L. Thermography in the diagnosis of diseases of the eye and the appraisal of therapeutic effects. A preliminary report. Acta Ophthalmolo (Copenh) 1970;48:945-958.
-
(1970)
Acta Ophthalmolo (Copenh)
, vol.48
, pp. 945-958
-
-
Wachtmeister, L.1
-
52
-
-
0028841060
-
Infrared thermography of the tear film in dry eye
-
Morgan PB, Tullo AB, Efron N. Infrared thermography of the tear film in dry eye. Eye 1995;9:615-618.
-
(1995)
Eye
, vol.9
, pp. 615-618
-
-
Morgan, P.B.1
Tullo, A.B.2
Efron, N.3
-
53
-
-
0031055619
-
Importance of the lipid layer in human tear film stability and evaporation
-
Craig JP. Importance of the lipid layer in human tear film stability and evaporation. Optom Vis Sci 1997;74:8-13.
-
(1997)
Optom Vis Sci
, vol.74
, pp. 8-13
-
-
Craig, J.P.1
-
54
-
-
0030057080
-
Ocular and skin temperature in ophthalmic postherpetic neuralgia
-
Cardona G, Morgan PB, Efron N, et al. Ocular and skin temperature in ophthalmic postherpetic neuralgia. Pain Clinic 1996;9:145-150.
-
(1996)
Pain Clinic
, vol.9
, pp. 145-150
-
-
Cardona, G.1
Morgan, P.B.2
Efron, N.3
-
55
-
-
0032804358
-
Ocular temperature in carotid artery stenosis
-
Morgan PB, Smyth JV, Tullo AB, et al. Ocular temperature in carotid artery stenosis. Optom Vis Sci 1999;76:850-854.
-
(1999)
Optom Vis Sci
, vol.76
, pp. 850-854
-
-
Morgan, P.B.1
Smyth, J.V.2
Tullo, A.B.3
-
56
-
-
0020042859
-
Normal variations in the thermographic pattern of the orbito-ocular region
-
Alio J, Padron M. Normal variations in the thermographic pattern of the orbito-ocular region. Diagn Imaging 1982a;51:93-98.
-
(1982)
Diagn Imaging
, vol.51
, pp. 93-98
-
-
Alio, J.1
Padron, M.2
-
58
-
-
0016316101
-
Corneal temperature in man and rabbit. Observations made using an infrared camera and a cold chamber
-
Rysa P, Sarvaranta J. Corneal temperature in man and rabbit. Observations made using an infrared camera and a cold chamber. Acta Ophthalmol (Copenh) 1974;52:810-816.
-
(1974)
Acta Ophthalmol (Copenh)
, vol.52
, pp. 810-816
-
-
Rysa, P.1
Sarvaranta, J.2
-
59
-
-
0016001011
-
Thermography of the eye during cold stress
-
Rysa P, Sarvaranta J. Thermography of the eye during cold stress. Acta Ophthalmol (Copenh) 1973;123:234-239.
-
(1973)
Acta Ophthalmol (Copenh)
, vol.123
, pp. 234-239
-
-
Rysa, P.1
Sarvaranta, J.2
-
60
-
-
0034603359
-
Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
-
Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach. Surv Ophthalmol 2000;44:367-408.
-
(2000)
Surv Ophthalmol
, vol.44
, pp. 367-408
-
-
Doughty, M.J.1
Zaman, M.L.2
-
61
-
-
0026717510
-
Architecture of the lid-cornea junction
-
Fatt I. Architecture of the lid-cornea junction. CLAO J 1992;18:187-192.
-
(1992)
CLAO J
, vol.18
, pp. 187-192
-
-
Fatt, I.1
-
62
-
-
0032718789
-
Variability in the measurement of corneal temperature using a non-contact infrared thermometer
-
Kocak I, Orgul S, Flammer J. Variability in the measurement of corneal temperature using a non-contact infrared thermometer. Ophthalmologica 1999;213:345-349.
-
(1999)
Ophthalmologica
, vol.213
, pp. 345-349
-
-
Kocak, I.1
Orgul, S.2
Flammer, J.3
-
64
-
-
0033037992
-
Relationship between corneal temperature and finger temperature
-
Girardin F, Orgul S, Erb C, et al. Relationship between corneal temperature and finger temperature. Arch Ophthalmol 1999;117:166-169.
-
(1999)
Arch Ophthalmol
, vol.117
, pp. 166-169
-
-
Girardin, F.1
Orgul, S.2
Erb, C.3
-
66
-
-
14844321389
-
-
Oxford, Butterworth-Heinemann
-
Korb DR, Craig JP, Doughty MJ, et al. The Tear Film: Structure, Function and Clinical Examination. Oxford, Butterworth-Heinemann, 2002.
-
(2002)
The Tear Film: Structure, Function and Clinical Examination
-
-
Korb, D.R.1
Craig, J.P.2
Doughty, M.J.3
-
67
-
-
0024555113
-
Age-related changes in pre-corneal tear film stability
-
Patel S, Farrell JC. Age-related changes in pre-corneal tear film stability. Optom Vis Sci 1989;66:175-178.
-
(1989)
Optom Vis Sci
, vol.66
, pp. 175-178
-
-
Patel, S.1
Farrell, J.C.2
-
68
-
-
0020059278
-
Influence of age on the temperature of the anterior segment of the eye
-
Alio J, Padron M. Influence of age on the temperature of the anterior segment of the eye. Ophthalmic Res 1982b;14:153-159.
-
(1982)
Ophthalmic Res
, vol.14
, pp. 153-159
-
-
Alio, J.1
Padron, M.2
-
69
-
-
32044457438
-
The dynamics of lid and eye-movements associated with blinking and eye closure
-
Vandersteen J, Steinman RM, Collewijn H. The dynamics of lid and eye-movements associated with blinking and eye closure. Experientia 1984;40:1298.
-
(1984)
Experientia
, vol.40
, pp. 1298
-
-
Vandersteen, J.1
Steinman, R.M.2
Collewijn, H.3
-
70
-
-
0032913957
-
Corneal surface temperature change as a mode of stimulation of the non-contact corneal aesthesiometer
-
Murphy PJ, Morgan PB, Patel S, et al. Corneal surface temperature change as a mode of stimulation of the non-contact corneal aesthesiometer. Cornea 1999;18:333-342.
-
(1999)
Cornea
, vol.18
, pp. 333-342
-
-
Murphy, P.J.1
Morgan, P.B.2
Patel, S.3
-
71
-
-
0034918227
-
The minimum stimulus energy require to produce a cooling sensation in the human cornea
-
Murphy PJ, Patel S, Morgan PB, et al. The minimum stimulus energy require to produce a cooling sensation in the human cornea. Ophthalmic Physiol Opt 2001;21:407-410.
-
(2001)
Ophthalmic Physiol Opt
, vol.21
, pp. 407-410
-
-
Murphy, P.J.1
Patel, S.2
Morgan, P.B.3
-
72
-
-
0020638479
-
A comparative study of tear evaporation rates and water content of soft contact lenses
-
Cedarstaff TH, Tomlinson A. A comparative study of tear evaporation rates and water content of soft contact lenses. Am J Optom Physiol Opt 1983;60:167-174.
-
(1983)
Am J Optom Physiol Opt
, vol.60
, pp. 167-174
-
-
Cedarstaff, T.H.1
Tomlinson, A.2
-
73
-
-
0038340377
-
The effects of ocular and lens parameters on the postlens tear thickness
-
Lin MC, Chen YQ, Polse KA. The effects of ocular and lens parameters on the postlens tear thickness. Eye Contact Lens 2003;29:S33-S36.
-
(2003)
Eye Contact Lens
, vol.29
-
-
Lin, M.C.1
Chen, Y.Q.2
Polse, K.A.3
-
76
-
-
2642590420
-
Use of digital infrared imaging to objectively assess thermal abnormalities in the human eye
-
Montoro J, Haverly RF, D'Arcy SJ, et al. Use of digital infrared imaging to objectively assess thermal abnormalities in the human eye. Thermology 1991;3:242-248.
-
(1991)
Thermology
, vol.3
, pp. 242-248
-
-
Montoro, J.1
Haverly, R.F.2
D'Arcy, S.J.3
-
77
-
-
0029904703
-
The effects of eye closure on protein and complement deposition on group IV hydrogel contact lenses: Relationship to tear flow dynamics
-
Sack R, Sathe S, Hackworth L. The effects of eye closure on protein and complement deposition on group IV hydrogel contact lenses: Relationship to tear flow dynamics. Curr Eye Res 1996;15:1092-1100.
-
(1996)
Curr Eye Res
, vol.15
, pp. 1092-1100
-
-
Sack, R.1
Sathe, S.2
Hackworth, L.3
-
78
-
-
0018188604
-
Corneal temperatures: A study of normal and laser-injured corneas in the Dutch belted rabbit
-
Mikesell GWJ. Corneal temperatures: A study of normal and laser-injured corneas in the Dutch belted rabbit. Am J Physiol Opt 1978;55:108-115.
-
(1978)
Am J Physiol Opt
, vol.55
, pp. 108-115
-
-
Mikesell, G.W.J.1
-
79
-
-
0023908839
-
Temperature of the hyperaemic bulbar conjunctiva
-
Efron N, Brennan N, Hore J, et al. Temperature of the hyperaemic bulbar conjunctiva. Curr Eye Res 1988;7:615-618.
-
(1988)
Curr Eye Res
, vol.7
, pp. 615-618
-
-
Efron, N.1
Brennan, N.2
Hore, J.3
-
80
-
-
32044436681
-
Ocular surface temperature (ocular thermography) as a predictor of corneal wound healing
-
Coles WH, Pandya RK, Anbar M, et al. Ocular surface temperature (ocular thermography) as a predictor of corneal wound healing. Invest Ophthalmol Vis Sci 1988;29:313.
-
(1988)
Invest Ophthalmol Vis Sci
, vol.29
, pp. 313
-
-
Coles, W.H.1
Pandya, R.K.2
Anbar, M.3
-
81
-
-
0028287959
-
Quantitative evaluation of post-surgical inflammation by infrared radiation thermometer and laser flare-cell meter
-
Fujishima H, Toda I, Yagi Y, et al. Quantitative evaluation of post-surgical inflammation by infrared radiation thermometer and laser flare-cell meter. J Cataract Refract Surg 1994;20:451-454.
-
(1994)
J Cataract Refract Surg
, vol.20
, pp. 451-454
-
-
Fujishima, H.1
Toda, I.2
Yagi, Y.3
-
82
-
-
0028921727
-
Increased comfort and decreased inflammation of the eye by cooling after cataract surgery
-
Fujishima H, Yagi Y, Toda I, et al. Increased comfort and decreased inflammation of the eye by cooling after cataract surgery. Am J Ophthalmol 1995;119:301-306.
-
(1995)
Am J Ophthalmol
, vol.119
, pp. 301-306
-
-
Fujishima, H.1
Yagi, Y.2
Toda, I.3
-
83
-
-
0025647187
-
Effect of artificial tear solutions and saline on tear film evaporation
-
Trees GR, Tomlinson A. Effect of artificial tear solutions and saline on tear film evaporation. Optom Vis Sci 1990;67:886-890.
-
(1990)
Optom Vis Sci
, vol.67
, pp. 886-890
-
-
Trees, G.R.1
Tomlinson, A.2
-
84
-
-
0030786029
-
Effects of artificial tear temperature on corneal sensation and subjective comfort
-
Fujishima H, Yagi Y, Shimazaki J, et al. Effects of artificial tear temperature on corneal sensation and subjective comfort. Cornea 1997;16:630-634.
-
(1997)
Cornea
, vol.16
, pp. 630-634
-
-
Fujishima, H.1
Yagi, Y.2
Shimazaki, J.3
-
86
-
-
0030950081
-
Corneal temperature changes during photorefractive keratectomy
-
Betney S, Morgan PB, Doyle SJ, et al. Corneal temperature changes during photorefractive keratectomy. Cornea 1997;16:158-161.
-
(1997)
Cornea
, vol.16
, pp. 158-161
-
-
Betney, S.1
Morgan, P.B.2
Doyle, S.J.3
-
87
-
-
0034977118
-
Thermal consequences of photorefractive keratectomy
-
Maldonado-Codina C, Morgan PB, Efron N. Thermal consequences of photorefractive keratectomy. Cornea 2001;20:509-515.
-
(2001)
Cornea
, vol.20
, pp. 509-515
-
-
Maldonado-Codina, C.1
Morgan, P.B.2
Efron, N.3
-
88
-
-
0032105507
-
Clinical thermal imaging today
-
Anbar M. Clinical thermal imaging today. IEEE Eng Med Biol Mag 1998;17:25-33.
-
(1998)
IEEE Eng Med Biol Mag
, vol.17
, pp. 25-33
-
-
Anbar, M.1
|