메뉴 건너뛰기




Volumn 54, Issue 1, 2005, Pages 14-19

Quantitative T1ρ and adiabatic Carr-Purcell T2 magnetic resonance imaging of human occipital lobe at 4 T

Author keywords

Adiabatic pulse; Contrast; High field; Human; MRI; Rotating frame; Spin lock; T1 relaxation

Indexed keywords

BRAIN; LOCKS (FASTENERS); MAGNETIC RESONANCE IMAGING;

EID: 21244438328     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20536     Document Type: Article
Times cited : (41)

References (19)
  • 5
    • 0024415458 scopus 로고
    • Spin locking for magnetic resonance imaging with application to human breast
    • Santyr GE, Henkelman RM, Bronskill MJ. Spin locking for magnetic resonance imaging with application to human breast. Magn Reson Med 1989;12:25-37.
    • (1989) Magn Reson Med , vol.12 , pp. 25-37
    • Santyr, G.E.1    Henkelman, R.M.2    Bronskill, M.J.3
  • 9
  • 10
    • 48549111126 scopus 로고
    • Highly selective π/2 and π pulse generation
    • Silver MS, Joseph RI, Hoult DI. Highly selective π/2 and π pulse generation. J Magn Reson 1984;59:347-351.
    • (1984) J Magn Reson , vol.59 , pp. 347-351
    • Silver, M.S.1    Joseph, R.I.2    Hoult, D.I.3
  • 11
    • 49149138125 scopus 로고
    • Compensation for pulse imperfections in NMR spin-echo experiments
    • Levitt MH, Freeman R. Compensation for pulse imperfections in NMR spin-echo experiments. J Magn Reson 1981;43:65-80.
    • (1981) J Magn Reson , vol.43 , pp. 65-80
    • Levitt, M.H.1    Freeman, R.2
  • 14
    • 0033045138 scopus 로고    scopus 로고
    • 2 in the brain of healthy subjects, patients with Parkinson disease, and patients with multiple system atrophy: Relation to iron content
    • 2 in the brain of healthy subjects, patients with Parkinson disease, and patients with multiple system atrophy: relation to iron content. Radiology 1999;211:489-495.
    • (1999) Radiology , vol.211 , pp. 489-495
    • Vymazal, J.1    Righini, A.2    Brooks, R.A.3    Canesi, M.4    Mariani, C.5    Leonardi, M.6    Pezzoli, G.7
  • 15
    • 0030067850 scopus 로고    scopus 로고
    • Estimation of the iron concentration in excised gray matter by means of proton relaxation measurements
    • Ye FQ, Martin W, Allen PS. Estimation of the iron concentration in excised gray matter by means of proton relaxation measurements. Magn Reson Med 1996;35:285-289.
    • (1996) Magn Reson Med , vol.35 , pp. 285-289
    • Ye, F.Q.1    Martin, W.2    Allen, P.S.3
  • 18
  • 19
    • 0001552791 scopus 로고
    • Nuclear magnetic relaxation in rotating frame
    • Blicharski JS. Nuclear magnetic relaxation in rotating frame. Acta Phys Polon 1972;41:223-236.
    • (1972) Acta Phys Polon , vol.41 , pp. 223-236
    • Blicharski, J.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.