Studies of efficiency in a perforated rotating disc contactor using a polymer-polymer aqueous two-phase systems

Author keywords

Extraction efficiency; Liquid liquid extraction; Perforated rotating disc contactor

Indexed keywords

CHEMICAL REACTORS; MASS TRANSFER; MIXTURES; PH EFFECTS; POLYETHYLENE GLYCOLS; PROTEINS; SODIUM COMPOUNDS;

EID: 21244432778     PISSN: 01046632     EISSN: None     Source Type: Journal    
DOI: 10.1590/S0104-66322005000300016     Document Type: Article
Times cited : (16)

References (12)
  • 2
    • 0017184389 scopus 로고
    • A rapid and sensitive method for the quantification of microgram quantities of protein utilizing the principles of protein-dye binding
    • Bradford MM (1976) A rapid and sensitive method for the quantification of microgram quantities of protein utilizing the principles of protein-dye binding. Anal. Biochem. 72: 248-254.
    • (1976) Anal. Biochem. , vol.72 , pp. 248-254
    • Bradford, M.M.1
  • 3
    • 0026809094 scopus 로고
    • Enzyme and protein mass transfer coefficient in aqueous two-phase system. I- Spray extraction columns
    • Jafarabad KR, Sawant SB, Joshi JB, Sidkar SK (1992) Enzyme and protein mass transfer coefficient in aqueous two-phase system. I- Spray extraction columns. Chem. Eng. Sci. 47: 57-68.
    • (1992) Chem. Eng. Sci. , vol.47 , pp. 57-68
    • Jafarabad, K.R.1    Sawant, S.B.2    Joshi, J.B.3    Sidkar, S.K.4
  • 4
    • 0025044797 scopus 로고
    • Dispersed-phase holdup and mass transfer in a rotating disc contactor with perforated skirts
    • Kawase Y (1990) Dispersed-phase holdup and mass transfer in a rotating disc contactor with perforated skirts. J. Chem. Technol. Biotechnol. 48: 247-260.
    • (1990) J. Chem. Technol. Biotechnol. , vol.48 , pp. 247-260
    • Kawase, Y.1
  • 5
    • 0031202603 scopus 로고
    • Enzyme mass transfer coefficient in aqueous two-phase systems: Modified spray extractions columns
    • Pawar PA, Parasu-Veera U, Sawant SB, Joshi JB (1993) Enzyme mass transfer coefficient in aqueous two-phase systems: modified spray extractions columns. The Canadian J. Chem. Eng. 75: 751-758.
    • (1993) The Canadian J. Chem. Eng. , vol.75 , pp. 751-758
    • Pawar, P.A.1    Parasu-Veera, U.2    Sawant, S.B.3    Joshi, J.B.4
  • 7
    • 0142056357 scopus 로고    scopus 로고
    • Extraction of recombinant cytochrome b5 from disrupted Escherichia coli cells with an aqueous two-phase system in a continuous perforated rotating contactor
    • Porto ALF, Lima-Filho JL, Aires-Barros MR, Cabral JMS, Tambourgi EB (1997) Extraction of recombinant cytochrome b5 from disrupted Escherichia coli cells with an aqueous two-phase system in a continuous perforated rotating contactor. Appl. Biochem. Biotechnol. 60: 114-122.
    • (1997) Appl. Biochem. Biotechnol. , vol.60 , pp. 114-122
    • Porto, A.L.F.1    Lima-Filho, J.L.2    Aires-Barros, M.R.3    Cabral, J.M.S.4    Tambourgi, E.B.5
  • 9
    • 0142121601 scopus 로고    scopus 로고
    • Performance of a perforated rotating disc contactor in the continuous extraction of a protein using the PEG-Cashew nut tree gum aqueous two-phase system
    • Sarubbo LA, Oliveira LA, Porto ALF., Lima-Filho JL, Campos-Takaki GM, Tambourgi EB (2003) Performance of a perforated rotating disc contactor in the continuous extraction of a protein using the PEG-Cashew nut tree gum aqueous two-phase system. Biochemical Engineering Journal, 16: 221-227.
    • (2003) Biochemical Engineering Journal , vol.16 , pp. 221-227
    • Sarubbo, L.A.1    Oliveira, L.A.2    Porto, A.L.F.3    Lima-Filho, J.L.4    Campos-Takaki, G.M.5    Tambourgi, E.B.6
  • 11
    • 21244486133 scopus 로고
    • São Carlos: R.A.M.C. Groote e A.A.S. Curvelo, USP
    • Rinaudo M and Milas M (1991) Polieletrólitos, São Carlos: R.A.M.C. Groote e A.A.S. Curvelo, USP.
    • (1991) Polieletrólitos
    • Rinaudo, M.1    Milas, M.2
  • 12
    • 0025438141 scopus 로고
    • Hydrodynamics and mass transfer in two-phase aqueous extraction using spray columns
    • Sawant SB, Sikdar SK (1990) Hydrodynamics and mass transfer in two-phase aqueous extraction using spray columns. Biotechnol. Bioeng. 36: 109-115.
    • (1990) Biotechnol. Bioeng. , vol.36 , pp. 109-115
    • Sawant, S.B.1    Sikdar, S.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.