Volumn 113, Issue 4, 2005, Pages 392-395

Measurements of fingers doses in X-ray guided surgery, nuclear medicine and research

Author keywords

[No Author keywords available]

Indexed keywords

PHOSPHORUS 32; STRONTIUM 90; TECHNETIUM 99M; YTTRIUM 90; PHOSPHORUS; STRONTIUM; TECHNETIUM; YTTRIUM;

EID: 21044454871     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nch488     Document Type: Article
Times cited : (12)

References (14)
  • 1
    • 0003602495 scopus 로고    scopus 로고
    • Catalogue of X-ray spectra and their characteristic data - ISO and DIN radiation qualities, therapy and diagnostic radiation qualities, unfiltered X-ray spectra
    • PTB-Bericht Dos-34. Physicalisch-Technische Bundesanstalt Braunschweig und Berlin Presse und Öffentlichkeitsarbeit Braunschweig
    • Ankerhold, U. Catalogue of X-ray spectra and their characteristic data - ISO and DIN radiation qualities, therapy and diagnostic radiation qualities, unfiltered X-ray spectra. PTB-Bericht Dos-34. Physicalisch-Technische Bundesanstalt Braunschweig und Berlin Presse und Öffentlichkeitsarbeit Braunschweig (2002).
    • (2002)
    • Ankerhold, U.1
  • 2
    • 0003653709 scopus 로고    scopus 로고
    • X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 1: Radiation characteristics and production methods
    • International Organization for Standardization. ISO 4037-1 (Geneva: ISO)
    • International Organization for Standardization. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 1: Radiation characteristics and production methods. ISO 4037-1 (Geneva: ISO) (1996).
    • (1996)
  • 4
    • 0003653711 scopus 로고    scopus 로고
    • X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of'photon energy - Part 3: Calibration of area and personal dosemeters and measurement of their response as a function of energy and angle of incidence
    • International Organization for Standardization. ISO 4037-3 (Geneva: ISO)
    • International Organization for Standardization. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of'photon energy - Part 3: Calibration of area and personal dosemeters and measurement of their response as a function of energy and angle of incidence. ISO 4037-3 (Geneva: ISO) (1999).
    • (1999)
  • 5
    • 21044457736 scopus 로고    scopus 로고
    • Regulations No. 1362 of November 21, 2003 on Radiation Protection and Use of Radiation (Radiation Protection Regulations)
    • The Norwegian Radiation Protection Authority. Available on (Last accessed 9 December)
    • The Norwegian Radiation Protection Authority. Regulations No. 1362 of November 21, 2003 on Radiation Protection and Use of Radiation (Radiation Protection Regulations). Available on http://www.nrpa.no/fpinternet/english/Publications/regulations.pdf (Last accessed 9 December 2004).
    • (2004)
  • 6
    • 0027369899 scopus 로고
    • Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic X-ray control
    • Goldstone, K. E., Wright, I. H. and Cohen, B. Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic X-ray control. Br. J. Radiol. 66, 899-901 (1993).
    • (1993) Br. J. Radiol. , vol.66 , pp. 899-901
    • Goldstone, K.E.1    Wright, I.H.2    Cohen, B.3
  • 7
    • 0030077848 scopus 로고    scopus 로고
    • Radiation dosage from use of the image intensifier in orthopaedic surgery
    • Lo, N. N., Goh, P. S. and Khong, K. S. Radiation dosage from use of the image intensifier in orthopaedic surgery. Singapore Med. J. 37, 69-71 (1996).
    • (1996) Singapore Med. J. , vol.37 , pp. 69-71
    • Lo, N.N.1    Goh, P.S.2    Khong, K.S.3
  • 9
    • 0031707419 scopus 로고    scopus 로고
    • Radiation exposure to medical staff in interventional and cardiac radiology
    • Vañó, E., González, L., Guibelalde, E., Fernándes, J. M. and Ten, J. I. Radiation exposure to medical staff in interventional and cardiac radiology. Br. J. Radiol. 71, 954-960 (1998).
    • (1998) Br. J. Radiol. , vol.71 , pp. 954-960
    • Vañó, E.1    González, L.2    Guibelalde, E.3    Fernándes, J.M.4    Ten, J.I.5
  • 11
    • 0742271723 scopus 로고    scopus 로고
    • Application of ALARP to extremity doses for hospital workers
    • Martin, C. J. and Whitby, M. Application of ALARP to extremity doses for hospital workers. J. Radiol. Prot. 23, 405-421 (2003).
    • (2003) J. Radiol. Prot. , vol.23 , pp. 405-421
    • Martin, C.J.1    Whitby, M.2
  • 12
    • 0037356439 scopus 로고    scopus 로고
    • Investigation using an advanced extremity gamma instrumentation system of options for shielding the hand during the preparation and injection of radiopharmaceuticals
    • Whitby, M. and Martin, C. J. Investigation using an advanced extremity gamma instrumentation system of options for shielding the hand during the preparation and injection of radiopharmaceuticals. J. Radiol. Prot. 23, 79-96 (2003).
    • (2003) J. Radiol. Prot. , vol.23 , pp. 79-96
    • Whitby, M.1    Martin, C.J.2
  • 13
    • 37449001388 scopus 로고    scopus 로고
    • Extremity doses of workers in nuclear medicine: Mapping hand doses in function of manipulation
    • Poster at IRPA 11, Madrid
    • Berus, D., Covens, P., Buls, N., Van den Broeck, M., Van Holsbeeck, G. and Vanhavere, F. Extremity doses of workers in nuclear medicine: mapping hand doses in function of manipulation. Poster at IRPA 11, Madrid (2004).
    • (2004)
    • Berus, D.1    Covens, P.2    Buls, N.3    Van den Broeck, M.4    Van Holsbeeck, G.5    Vanhavere, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.