메뉴 건너뛰기




Volumn 13, Issue 2, 2005, Pages 97-106

Measuring the body temperature: How accurate is the Tempa Dot®?

Author keywords

Body temperature; Diagnostic studies; Fever; Method comparison; Sensitivity; Thermometer

Indexed keywords

MERCURY;

EID: 21044447937     PISSN: 09287329     EISSN: None     Source Type: Journal    
DOI: 10.3233/thc-2005-13203     Document Type: Article
Times cited : (8)

References (30)
  • 1
    • 0025308062 scopus 로고
    • Correlating reported fever in young infants with subsequent temperature patterns and rate of serious bacterial infections
    • W.A. Bonadio, M. Hegenbarth and M. Zachariason, Correlating reported fever in young infants with subsequent temperature patterns and rate of serious bacterial infections, Pediatr Infect Dis J 9 (1990), 158-160.
    • (1990) Pediatr Infect Dis J , vol.9 , pp. 158-160
    • Bonadio, W.A.1    Hegenbarth, M.2    Zachariason, M.3
  • 2
    • 0014899786 scopus 로고
    • New episodes of fever in hospitalized children
    • K. Konerding and H.L. Moffet, New episodes of fever in hospitalized children, Am J Dis Child 120 (1970), 515-519.
    • (1970) Am J Dis Child , vol.120 , pp. 515-519
    • Konerding, K.1    Moffet, H.L.2
  • 3
    • 0023695223 scopus 로고
    • Should the temperature chart influence management in cardiac operations? Result of a prospective study in 314 patients
    • A.P. Wilson, T. Treasure, R.N. Gruneberg, M.F. Sturridge and J. Burridge, Should the temperature chart influence management in cardiac operations? Result of a prospective study in 314 patients, J Thorac Cardiovasc Surg 96 (1988), 518-523.
    • (1988) J Thorac Cardiovasc Surg , vol.96 , pp. 518-523
    • Wilson, A.P.1    Treasure, T.2    Gruneberg, R.N.3    Sturridge, M.F.4    Burridge, J.5
  • 4
    • 0037167250 scopus 로고    scopus 로고
    • Infrared ear thermometry compared with rectal thermometry in children: A systematic review
    • J.V. Craig, G.A. Lancaster, S. Taylor, P.R. Williamson and R.L. Smyth, Infrared ear thermometry compared with rectal thermometry in children: a systematic review, Lancet 360 (2002), 603-609.
    • (2002) Lancet , vol.360 , pp. 603-609
    • Craig, J.V.1    Lancaster, G.A.2    Taylor, S.3    Williamson, P.R.4    Smyth, R.L.5
  • 5
    • 0033763404 scopus 로고    scopus 로고
    • Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers
    • B.N. Jensen, F.S. Jensen, S.N. Madsen and K. Lossl, Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers, Eur J Surg 166 (2000), 848-851.
    • (2000) Eur J Surg , vol.166 , pp. 848-851
    • Jensen, B.N.1    Jensen, F.S.2    Madsen, S.N.3    Lossl, K.4
  • 7
    • 0027177769 scopus 로고
    • Parents' perceptions of taking babies' rectal temperature
    • J. Kai, Parents' perceptions of taking babies' rectal temperature, BMJ 307 (1993), 660-662.
    • (1993) BMJ , vol.307 , pp. 660-662
    • Kai, J.1
  • 8
    • 0019765894 scopus 로고
    • Salmonella cross-infection associated with contamination of rectal thermometers
    • G.L. French, Salmonella cross-infection associated with contamination of rectal thermometers, J Hosp Infect 2 (1981), 389-390.
    • (1981) J Hosp Infect , vol.2 , pp. 389-390
    • French, G.L.1
  • 9
    • 0019774943 scopus 로고
    • Rectal thermometer mediated cross-infection with Salmonella wandsworth in a paediatric ward
    • S.W. Im, K. Chow and P.Y. Chau, Rectal thermometer mediated cross-infection with Salmonella wandsworth in a paediatric ward, J Hosp Infect 2 (1981), 171-174.
    • (1981) J Hosp Infect , vol.2 , pp. 171-174
    • Im, S.W.1    Chow, K.2    Chau, P.Y.3
  • 10
    • 0022592969 scopus 로고
    • Outbreak of Salmonella eimsbuettel in newborn infants spread by rectal thermometers
    • T.A. McAllister, J.A. Roud, A. Marshall, B.M. Holland and T.L. Turner, Outbreak of Salmonella eimsbuettel in newborn infants spread by rectal thermometers, Lancet 1 (1986), 1262-1264.
    • (1986) Lancet , vol.1 , pp. 1262-1264
    • McAllister, T.A.1    Roud, J.A.2    Marshall, A.3    Holland, B.M.4    Turner, T.L.5
  • 11
    • 0019066430 scopus 로고
    • Three-minute time interval when using an oral mercury-in-glass thermometer with or without J-temp sheaths
    • R.D. Graves and M.F. Markarian, Three-minute time interval when using an oral mercury-in-glass thermometer with or without J-temp sheaths, Nurs Res 29 (1980), 323-324.
    • (1980) Nurs Res , vol.29 , pp. 323-324
    • Graves, R.D.1    Markarian, M.F.2
  • 12
    • 0021752780 scopus 로고
    • Permeability of the thermometer sheath when taking oral temperatures
    • D.J. Soltero, E.E. Sommers and E.L. Truelove, Permeability of the thermometer sheath when taking oral temperatures, Infect Control 5 (1984), 435-437.
    • (1984) Infect Control , vol.5 , pp. 435-437
    • Soltero, D.J.1    Sommers, E.E.2    Truelove, E.L.3
  • 13
    • 0022775459 scopus 로고
    • A comparison of mercury and digital clinical thermometers
    • S.P. Davies, J.Y. Kassab, A.J. Thrush and P.H. Smith, A comparison of mercury and digital clinical thermometers, J Adv Nurs 11 (1986), 535-543.
    • (1986) J Adv Nurs , vol.11 , pp. 535-543
    • Davies, S.P.1    Kassab, J.Y.2    Thrush, A.J.3    Smith, P.H.4
  • 15
    • 0022929630 scopus 로고
    • Mercury vapour levels in a domestic environment following breakage of a clinical thermometer
    • E.R. Smart, Mercury vapour levels in a domestic environment following breakage of a clinical thermometer, Sci Total Environ 57 (1986), 99-103.
    • (1986) Sci Total Environ , vol.57 , pp. 99-103
    • Smart, E.R.1
  • 16
    • 0018410072 scopus 로고
    • Mercury vapor as a contaminant of hospital environment
    • A.T. Choi-Lao, G. Corte, G. Dowd and R.C. Lao, Mercury vapor as a contaminant of hospital environment, Sci Total Environ 11 (1979), 287-292.
    • (1979) Sci Total Environ , vol.11 , pp. 287-292
    • Choi-Lao, A.T.1    Corte, G.2    Dowd, G.3    Lao, R.C.4
  • 17
    • 0029646368 scopus 로고
    • Comparison of disposable and glass mercury thermometers
    • M. Board, Comparison of disposable and glass mercury thermometers, Nurs Times 91 (1995), 36-37.
    • (1995) Nurs Times , vol.91 , pp. 36-37
    • Board, M.1
  • 18
    • 0026816315 scopus 로고
    • Reduction in the incidence of Clostridium difficile-associated diarrhea in an acute care hospital and a skilled nursing facility following replacement of electronic thermometers with single-use disposables
    • S.E. Brooks, R.O. Veal, M. Kramer, L. Dore, N. Schupf and M. Adachi, Reduction in the incidence of Clostridium difficile-associated diarrhea in an acute care hospital and a skilled nursing facility following replacement of electronic thermometers with single-use disposables, Infect Control Hosp Epidemiol 13 (1992), 98-1-03.
    • (1992) Infect Control Hosp Epidemiol , vol.13
    • Brooks, S.E.1    Veal, R.O.2    Kramer, M.3    Dore, L.4    Schupf, N.5    Adachi, M.6
  • 19
    • 0036582782 scopus 로고    scopus 로고
    • Management of an outbreak of Enterobacter cloacae in a neonatal unit using simple preventive measures
    • Y. Dijk, E.M. Bik, S. Hochstenbach-Vernooij, G.J. Vlist, P.H. Savelkoul, J.A. Kaan et al., Management of an outbreak of Enterobacter cloacae in a neonatal unit using simple preventive measures, J Hosp Infect 51 (2002), 21-26.
    • (2002) J Hosp Infect , vol.51 , pp. 21-26
    • Dijk, Y.1    Bik, E.M.2    Hochstenbach-Vernooij, S.3    Vlist, G.J.4    Savelkoul, P.H.5    Kaan, J.A.6
  • 20
    • 0026420792 scopus 로고
    • Measurement of basal temperature with the Tempadot disposable thermometer for oral use
    • M. Weischer, A. Friis-Moller and A. Bremmelgaard, [Measurement of basal temperature with the Tempadot disposable thermometer for oral use], Ugeskr Laeger 153 (1991), 3538-3540.
    • (1991) Ugeskr Laeger , vol.153 , pp. 3538-3540
    • Weischer, M.1    Friis-Moller, A.2    Bremmelgaard, A.3
  • 22
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • J.M. Bland and D.G. Altman, Measuring agreement in method comparison studies, Stat Methods Med Res 8 (1999), 135-160.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 23
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, Part I
    • H. Passing Bablok, A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, Part I, J Clin Chem Clin Biochem 21 (1983), 709-720.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing Bablok, H.1
  • 24
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J.M. Bland and D.G. Altman, Statistical methods for assessing agreement between two methods of clinical measurement, Lancet 1 (1986), 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 25
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • J.M. Bland and D.G. Altman, Measuring agreement in method comparison studies, Stat Methods Med Res 8 (1999), 135-160.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 26
    • 0032403073 scopus 로고    scopus 로고
    • The relative accuracy of mercury, Tempa-DOT and FeverScan thermometers
    • C. Morley, M. Murray and K. Whybrew, The relative accuracy of mercury, Tempa-DOT and FeverScan thermometers, Early Hum Dev 53 (1998), 171-178.
    • (1998) Early Hum Dev , vol.53 , pp. 171-178
    • Morley, C.1    Murray, M.2    Whybrew, K.3
  • 27
    • 0029957695 scopus 로고    scopus 로고
    • Modern electronic and chemical thermometers used in the axilla are inaccurate
    • S.T. Zengeya and I. Blumenthal, Modern electronic and chemical thermometers used in the axilla are inaccurate, Eur J Pediatr 155 (1996), 1005-1008.
    • (1996) Eur J Pediatr , vol.155 , pp. 1005-1008
    • Zengeya, S.T.1    Blumenthal, I.2
  • 28
    • 0028411945 scopus 로고
    • Accuracy and reliability of temperature measurement by instrument and site
    • S. Pontious, A.H. Kennedy, S. Shelley and C. Mittrucker, Accuracy and reliability of temperature measurement by instrument and site, J Pediatr Nurs 9 (1994), 114-123.
    • (1994) J Pediatr Nurs , vol.9 , pp. 114-123
    • Pontious, S.1    Kennedy, A.H.2    Shelley, S.3    Mittrucker, C.4
  • 29
    • 0032130313 scopus 로고    scopus 로고
    • A comparison of temperature-taking methods in neonates
    • M.K. Leick-Rude and L.F. Bloom, A comparison of temperature-taking methods in neonates, Neonatal Netw 17 (1998), 21-37.
    • (1998) Neonatal Netw , vol.17 , pp. 21-37
    • Leick-Rude, M.K.1    Bloom, L.F.2
  • 30
    • 0030090297 scopus 로고    scopus 로고
    • Accuracy of chemical dot thermometers in critically ill adults and young children
    • R.S. Erickson, L.T. Meyer and T.M. Woo, Accuracy of chemical dot thermometers in critically ill adults and young children, Image J Nurs Sch 28 (1996), 23-28.
    • (1996) Image J Nurs Sch , vol.28 , pp. 23-28
    • Erickson, R.S.1    Meyer, L.T.2    Woo, T.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.