메뉴 건너뛰기




Volumn 13, Issue 10, 2005, Pages 1307-1314

Actuator fault compensation for a winding machine

Author keywords

Fault accommodation; Fault tolerant control; Isolation filter; Web tension control; Winding system

Indexed keywords

ACTUATORS; EIGENVALUES AND EIGENFUNCTIONS; ELECTRIC FILTERS; MACHINE DESIGN;

EID: 20944446711     PISSN: 09670661     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.conengprac.2004.11.016     Document Type: Article
Times cited : (29)

References (34)
  • 1
    • 0000250822 scopus 로고
    • Fault diagnosis and reconfiguration of systems using fuzzy logic: Application to a thermal plant treatment process
    • C. Aubrun D. Sauter H. Noura & M. Robert Fault diagnosis and reconfiguration of systems using fuzzy logic: Application to a thermal plant treatment process International Journal of System Sciences 24 1993 1945-1954
    • (1993) International Journal of System Sciences , vol.24 , pp. 1945-1954
    • Aubrun, C.1    Sauter, D.2    Noura, H.3    Robert, M.4
  • 3
    • 0004017633 scopus 로고
    • Failure accommodation in linear systems through self-reorganisation
    • Ph.D. dissertation, MA
    • Beard, R. V. (1971). Failure accommodation in linear systems through self-reorganisation. Ph.D. dissertation, MA.
    • (1971)
    • Beard, R.V.1
  • 8
    • 0000775115 scopus 로고
    • Reconfigurable control system design via perfect model following
    • Z. Gao & P.J. Antsaklis Reconfigurable control system design via perfect model following International Journal of Control 56 4 1992 783-798
    • (1992) International Journal of Control , vol.56 , Issue.4 , pp. 783-798
    • Gao, Z.1    Antsaklis, P.J.2
  • 9
    • 0032024512 scopus 로고    scopus 로고
    • Improvements in product quality in tandem cold rolling using robust multivariable control
    • J.E. Geddes & M. Poslethwaite Improvements in product quality in tandem cold rolling using robust multivariable control IEEE Transaction on Control systems 6 2 1998
    • (1998) IEEE Transaction on Control Systems , vol.6 , Issue.2
    • Geddes, J.E.1    Poslethwaite, M.2
  • 11
    • 78751657805 scopus 로고    scopus 로고
    • Fault isolation filter with unknown inputs in stochastic systems
    • Jamouli, H., Keller, J. Y., & Sauter, D. (2003). Fault isolation filter with unknown inputs in stochastic systems. IFAC Safeprocess'03, Washington (pp. 531-536).
    • (2003) IFAC Safeprocess'03, Washington , pp. 531-536
    • Jamouli, H.1    Keller, J.Y.2    Sauter, D.3
  • 12
    • 0032302657 scopus 로고    scopus 로고
    • Fault tolerant control systems synthesis using imprecise fault identification and reconfigurable control
    • Gaithersburg, MD, USA
    • Jiang, J., & Zhao, Q. (1998). Fault tolerant control systems synthesis using imprecise fault identification and reconfigurable control. IEEE ISIC/CIRA/ISAS joint conference. Gaithersburg, MD, USA (pp. 169-174).
    • (1998) IEEE ISIC/CIRA/ISAS Joint Conference , pp. 169-174
    • Jiang, J.1    Zhao, Q.2
  • 13
    • 0004055887 scopus 로고
    • Failure detection in linear systems
    • Ph.D. dissertation, MA, USA
    • Jones, H. L. (1973). Failure detection in linear systems. Ph.D. dissertation, MA, USA.
    • (1973)
    • Jones, H.L.1
  • 14
    • 0032598754 scopus 로고    scopus 로고
    • Fault isolation filter for linear systems
    • J.Y. Keller Fault isolation filter for linear systems Automatica 35 1999 1701-1706
    • (1999) Automatica , vol.35 , pp. 1701-1706
    • Keller, J.Y.1
  • 16
    • 0023456666 scopus 로고
    • Unbaised minimum-variance linear state estimation
    • P.K. Kitandis Unbaised minimum-variance linear state estimation Automatica 23 1987 775-778
    • (1987) Automatica , vol.23 , pp. 775-778
    • Kitandis, P.K.1
  • 17
    • 0043022227 scopus 로고    scopus 로고
    • Tension control for winding systems with two degrees of freedom H'infinity' controller
    • D. Knittel E. Laroche D. Gigan & H. Koc Tension control for winding systems with two degrees of freedom H'infinity' controller IEEE Transactions on Industry Applications 39 1 2003 113-120
    • (2003) IEEE Transactions on Industry Applications , vol.39 , Issue.1 , pp. 113-120
    • Knittel, D.1    Laroche, E.2    Gigan, D.3    Koc, H.4
  • 19
    • 20944436599 scopus 로고    scopus 로고
    • Fault isolation filter design for time invariant systems
    • B. Liu & J. Si Fault isolation filter design for time invariant systems IEEE Transactions on Automatic Control AC-21 1997 775-778
    • (1997) IEEE Transactions on Automatic Control , vol.AC-21 , pp. 775-778
    • Liu, B.1    Si, J.2
  • 20
    • 0022785653 scopus 로고
    • A geometric approach to the synthesis of failure detection filters
    • M. Massoumnia A geometric approach to the synthesis of failure detection filters IEEE Transactions on Automatic Control AC-31 1986 839-846
    • (1986) IEEE Transactions on Automatic Control , vol.AC-31 , pp. 839-846
    • Massoumnia, M.1
  • 23
    • 0034140527 scopus 로고    scopus 로고
    • Fault-tolerant control in dynamic systems: Application to a winding machine
    • H. Noura D. Sauter F. Hamelin & D. Theilliol Fault-tolerant control in dynamic systems: Application to a winding machine IEEE Control Systems Magazine 20 1 2000 33-94
    • (2000) IEEE Control Systems Magazine , vol.20 , Issue.1 , pp. 33-94
    • Noura, H.1    Sauter, D.2    Hamelin, F.3    Theilliol, D.4
  • 24
    • 0013319753 scopus 로고
    • A new interpretation of the fault detection filter: Part 1
    • J. Park & G. Rizzoni A new interpretation of the fault detection filter: Part 1 International Journal of Control 60 1994 767-787
    • (1994) International Journal of Control , vol.60 , pp. 767-787
    • Park, J.1    Rizzoni, G.2
  • 25
    • 0344075614 scopus 로고
    • A new interpretation of the fault detection filter: Part 2
    • J. Park & G. Rizzoni A new interpretation of the fault detection filter: Part 2 International Journal of Control 60 1994 1033-1055
    • (1994) International Journal of Control , vol.60 , pp. 1033-1055
    • Park, J.1    Rizzoni, G.2
  • 26
    • 0000368449 scopus 로고    scopus 로고
    • The 1997 situation
    • Hull, UK, 2, (survey)
    • Patton, R. J. (1997). The 1997 situation (survey). IFAC SAFEPROCESS'97, Hull, UK, 2 (pp. 26-28).
    • (1997) IFAC SAFEPROCESS'97 , pp. 26-28
    • Patton, R.J.1
  • 27
    • 0029512614 scopus 로고
    • Autonomous control reconfiguration
    • H.E. Rausch Autonomous control reconfiguration IEEE Control Systems Magazine 15 6 1995 37-49
    • (1995) IEEE Control Systems Magazine , vol.15 , Issue.6 , pp. 37-49
    • Rausch, H.E.1
  • 28
    • 0032635817 scopus 로고    scopus 로고
    • Frequency-domain optimization for robust fault detection and isolation in dynamic systems
    • D. Sauter & F. Hamelin Frequency-domain optimization for robust fault detection and isolation in dynamic systems IEEE Transaction on Automatic Control 44 1999 878-883
    • (1999) IEEE Transaction on Automatic Control , vol.44 , pp. 878-883
    • Sauter, D.1    Hamelin, F.2
  • 29
    • 0036633841 scopus 로고    scopus 로고
    • Fault diagnosis and accommodation of a three-tank-system based on analytical redundancy
    • D. Theilliol H. Noura & J.C. Ponsart Fault diagnosis and accommodation of a three-tank-system based on analytical redundancy ISA Transactions 41 3 2002 365-382
    • (2002) ISA Transactions , vol.41 , Issue.3 , pp. 365-382
    • Theilliol, D.1    Noura, H.2    Ponsart, J.C.3
  • 30
    • 0032279566 scopus 로고    scopus 로고
    • Fault-tolerant control method for actuator and component faults
    • Tampa, USA
    • Theilliol, D., Noura, H., & Sauter, D. (1998). Fault-tolerant control method for actuator and component faults. IEEE Conference on Decision and Control, Tampa, USA (pp. 604-608).
    • (1998) IEEE Conference on Decision and Control , pp. 604-608
    • Theilliol, D.1    Noura, H.2    Sauter, D.3
  • 34
    • 0032182773 scopus 로고    scopus 로고
    • Reliable state feedback control system design against actuator failures
    • Q. Zhao & J. Jiang Reliable state feedback control system design against actuator failures Automatica 34 10 1998 1267-1272
    • (1998) Automatica , vol.34 , Issue.10 , pp. 1267-1272
    • Zhao, Q.1    Jiang, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.