메뉴 건너뛰기




Volumn 40, Issue 8, 2005, Pages 1507-1524

Use of flow injection and sequential injection analysis schemes for the determination of trace-level concentrations of metals in complex matrices by etaas and icpms

Author keywords

ETAAS; Flow injection; ICPMS; Lab on valve; Preconcentration; Separation; Sequential injection; Trace level metal concentrations

Indexed keywords

ABSORPTION SPECTROSCOPY; HYDROPHILICITY; HYDROPHOBICITY; INDUCTIVELY COUPLED PLASMA; ION EXCHANGE; MASS SPECTROMETRY; METAL ANALYSIS; PRECIPITATION (CHEMICAL);

EID: 20944434497     PISSN: 10934529     EISSN: None     Source Type: Journal    
DOI: 10.1081/ESE-200060600     Document Type: Conference Paper
Times cited : (13)

References (36)
  • 2
    • 0025168899 scopus 로고
    • Sequential injection: A new concept for chemical sensors, process analysis and laboratory assays
    • Ruzicka, J.; Marshall, G.D. Sequential injection: a new concept for chemical sensors, process analysis and laboratory assays. Anal. Chim. Acta 1990, 237, 329-343.
    • (1990) Anal. Chim. Acta , vol.237 , pp. 329-343
    • Ruzicka, J.1    Marshall, G.D.2
  • 3
    • 0034613424 scopus 로고    scopus 로고
    • Interfacing flow injection analysis (sequential injection analysis) and electro-thermal atomic absorption spectrometry. Determination of trace-levels of Cr(VI) via on-line pre-concentration by adsorption in a knotted reactor and by liquid-liquid extraction
    • Nielsen, S.; Hansen, E.H. Interfacing flow injection analysis (sequential injection analysis) and electro-thermal atomic absorption spectrometry. Determination of trace-levels of Cr(VI) via on-line pre-concentration by adsorption in a knotted reactor and by liquid-liquid extraction. Anal. Chim Acta 2000, 422, 47-62.
    • (2000) Anal. Chim. Acta , vol.422 , pp. 47-62
    • Nielsen, S.1    Hansen, E.H.2
  • 4
    • 0036026492 scopus 로고    scopus 로고
    • FI/SI on-line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead
    • Wang, J.-H.; Hansen, E.H. FI/SI on-line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead. J. Anal. At. Spectrom. 2002, 17, 1284-1289.
    • (2002) J. Anal. At. Spectrom. , vol.17 , pp. 1284-1289
    • Wang, J.-H.1    Hansen, E.H.2
  • 6
    • 0034299561 scopus 로고    scopus 로고
    • Trace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor
    • Benkhedda, K.; Infante, H.G.; Ivanova, E.; Adams, F. Trace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor. J. Anal. At. Spectrom. 2000, 15, 1349-1356.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 1349-1356
    • Benkhedda, K.1    Infante, H.G.2    Ivanova, E.3    Adams, F.4
  • 7
    • 0034607860 scopus 로고    scopus 로고
    • Flow-injection hydride generation atomic absorption spectrometric study of the automated on-line pre-reduction of arsenate, methylarsonate and dimethylarsinate and high-performance liquid chromatographic separation of their 1-cysteine complexes
    • Tsalev, D.L.; Sperling, M.; Welz, B. Flow-injection hydride generation atomic absorption spectrometric study of the automated on-line pre-reduction of arsenate, methylarsonate and dimethylarsinate and high-performance liquid chromatographic separation of their 1-cysteine complexes. Talanta 2000, 51, 1059-1068.
    • (2000) Talanta , vol.51 , pp. 1059-1068
    • Tsalev, D.L.1    Sperling, M.2    Welz, B.3
  • 8
    • 0029879990 scopus 로고    scopus 로고
    • Determination of ultra-trace amounts of selenium(IV) by flow injection hydride generation atomic absorption spectrometry with on-line preconcentration by coprecipitation with lanthanium hydroxide. Part II. On-line addition of coprecipating agent
    • Nielsen, S.; Sloth, J.J.; Hansen, E.H. Determination of ultra-trace amounts of selenium(IV) by flow injection hydride generation atomic absorption spectrometry with on-line preconcentration by coprecipitation with lanthanium hydroxide. Part II. On-line addition of coprecipating agent. Analyst 1996, 121, 31-35.
    • (1996) Analyst , vol.121 , pp. 31-35
    • Nielsen, S.1    Sloth, J.J.2    Hansen, E.H.3
  • 9
    • 0034564977 scopus 로고    scopus 로고
    • Coupling on-line preconcentration by ion-exchange with ETAAS. A novel flow injection approach based on the use of a renewable micro-column as demonstrated for the determination of nickel in environmental and biological samples
    • Wang, J.-H.; Hansen, E.H. Coupling on-line preconcentration by ion-exchange with ETAAS. A novel flow injection approach based on the use of a renewable micro-column as demonstrated for the determination of nickel in environmental and biological samples. Anal. Chim. Acta 2000, 424, 223-232.
    • (2000) Anal. Chim. Acta , vol.424 , pp. 223-232
    • Wang, J.-H.1    Hansen, E.H.2
  • 10
    • 0033797725 scopus 로고    scopus 로고
    • Flow injection on-line two-stage solvent extraction preconcentration coupled with electrothermal atomic absorption spectrometry for determination of bismuth in biological and environmental samples
    • Wang, J.-H.; Hansen, E.H. Flow injection on-line two-stage solvent extraction preconcentration coupled with electrothermal atomic absorption spectrometry for determination of bismuth in biological and environmental samples. Anal. Lett. 2000, 33, 2747-2766.
    • (2000) Anal. Lett. , vol.33 , pp. 2747-2766
    • Wang, J.-H.1    Hansen, E.H.2
  • 11
    • 0035543724 scopus 로고    scopus 로고
    • Interfacing sequential injection on-line preconcentration using a renewable micro-column incorporated in a "lab-on-valve" system with direct injection nebulization inductively coupled plasma mass spectrometry
    • Wang, J.-H.; Hansen, E.H. Interfacing sequential injection on-line preconcentration using a renewable micro-column incorporated in a "lab-on-valve" system with direct injection nebulization inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 2001, 16, 1349-1355.
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 1349-1355
    • Wang, J.-H.1    Hansen, E.H.2
  • 12
    • 0037118793 scopus 로고    scopus 로고
    • Flow injection on-line preconcentration of low levels of Cr(VI) with detection by ETAAS. Comparison of using an open tubular PTFE knotted reactor and a column reactor packed with PTFE beads
    • Som-aum, W.; Liawruangrath, S.; Hansen, E.H. Flow injection on-line preconcentration of low levels of Cr(VI) with detection by ETAAS. Comparison of using an open tubular PTFE knotted reactor and a column reactor packed with PTFE beads. Anal. Chim. Acta 2002, 463, 99-109.
    • (2002) Anal. Chim. Acta , vol.463 , pp. 99-109
    • Som-aum, W.1    Liawruangrath, S.2    Hansen, E.H.3
  • 14
    • 0037041220 scopus 로고    scopus 로고
    • Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry
    • Wang, J.-H.; Hansen, E.H. Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry. Anal. Chim. Acta 2002, 456, 283-292.
    • (2002) Anal. Chim. Acta , vol.456 , pp. 283-292
    • Wang, J.-H.1    Hansen, E.H.2
  • 16
    • 0021683497 scopus 로고
    • An efficient flow-injection system with on-line ion-exchange preconcentration for determination of trace amounts of heavy metals by absorption spectrometry
    • Fang, Z.-L.; Ruzicka, J.; Hansen, E.H. An efficient flow-injection system with on-line ion-exchange preconcentration for determination of trace amounts of heavy metals by absorption spectrometry. Anal. Chim. Acta 1984, 164, 23-39.
    • (1984) Anal. Chim. Acta , vol.164 , pp. 23-39
    • Fang, Z.-L.1    Ruzicka, J.2    Hansen, E.H.3
  • 17
    • 0033118255 scopus 로고    scopus 로고
    • From flow injection to bead injection
    • Ruzicka, J.; Scampavia, L. From flow injection to bead injection. Anal. Chem. 1999, 71, 257A-263A.
    • (1999) Anal. Chem. , vol.71
    • Ruzicka, J.1    Scampavia, L.2
  • 18
    • 11444263294 scopus 로고    scopus 로고
    • Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS
    • Wang, J.-H.; Hansen, E.H. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS. Trends Anal. Chem. 2005, 24, 1-8.
    • (2005) Trends Anal. Chem. , vol.24 , pp. 1-8
    • Wang, J.-H.1    Hansen, E.H.2
  • 19
    • 0034084022 scopus 로고    scopus 로고
    • Lab-on-valve: Universal microflow analyzer based on sequential and bead injection
    • Ruzicka J. Lab-on-valve: universal microflow analyzer based on sequential and bead injection. Analyst 2000, 125, 1053-1060.
    • (2000) Analyst , vol.125 , pp. 1053-1060
    • Ruzicka, J.1
  • 20
    • 0035069789 scopus 로고    scopus 로고
    • Micro sequential injection: Fermentation monitoring of ammonia, glycerol, glucose, and free iron using the novel lab-on-valve system
    • Wu, C. H.; Scampavia, L.; Ruzicka, J.; Zamost, B. Micro sequential injection: fermentation monitoring of ammonia, glycerol, glucose, and free iron using the novel lab-on-valve system. Analyst 2001, 126, 291-297.
    • (2001) Analyst , vol.126 , pp. 291-297
    • Wu, C.H.1    Scampavia, L.2    Ruzicka, J.3    Zamost, B.4
  • 21
    • 0037015115 scopus 로고    scopus 로고
    • Implementation of suitable FI/SI-sample separation/preconcentration schemes for determination of trace metal concentrations using detection by ETAAS and ICPMS
    • Hansen, E. H.; Wang, J.-H. Implementation of suitable FI/SI-sample separation/preconcentration schemes for determination of trace metal concentrations using detection by ETAAS and ICPMS. Anal. Chim. Acta 2002, 467, 3-12.
    • (2002) Anal. Chim. Acta , vol.467 , pp. 3-12
    • Hansen, E.H.1    Wang, J.-H.2
  • 22
    • 0035942525 scopus 로고    scopus 로고
    • Coupling sequential injection on-line preconcentration by means of a renewable microcolumn with ion-exchange beads with detection by electrothermal atomic absorption spectrometry. Comparing the performance of eluting the loaded beads with transporting them directly into the graphite tube, as demonstrated for the determination of nickel in environmental and biological samples
    • Wang, J.-H.; Hansen, E. H. Coupling sequential injection on-line preconcentration by means of a renewable microcolumn with ion-exchange beads with detection by electrothermal atomic absorption spectrometry. Comparing the performance of eluting the loaded beads with transporting them directly into the graphite tube, as demonstrated for the determination of nickel in environmental and biological samples. Anal. Chim. Acta 2001, 435, 331-342.
    • (2001) Anal. Chim. Acta , vol.435 , pp. 331-342
    • Wang, J.-H.1    Hansen, E.H.2
  • 23
    • 0034878335 scopus 로고    scopus 로고
    • On-line ion exchange preconcentration in a sequential injection lab-on-valve microsystem incorporating a renewable column with ETAAS for the trace-level determination of bismuth in urine and river sediment
    • Wang, J.-H.; Hansen, E.H. On-line ion exchange preconcentration in a sequential injection lab-on-valve microsystem incorporating a renewable column with ETAAS for the trace-level determination of bismuth in urine and river sediment. Atom. Spectrosc. 2001, 22, 312-318.
    • (2001) Atom. Spectrosc. , vol.22 , pp. 312-318
    • Wang, J.-H.1    Hansen, E.H.2
  • 24
    • 0344845226 scopus 로고    scopus 로고
    • Sequential injection-bead injection-lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry
    • Wang, J.-H.; Hansen, E.H.; Miró, M. Sequential injection-bead injection-lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry. Anal. Chim. Acta 2003, 499, 139-147.
    • (2003) Anal. Chim. Acta , vol.499 , pp. 139-147
    • Wang, J.-H.1    Hansen, E.H.2    Miró, M.3
  • 25
    • 0037384424 scopus 로고    scopus 로고
    • Sequential injection lab-on-valve: The third generation of flow injection analysis
    • Wang, J.-H.; Hansen, E.H. Sequential injection lab-on-valve: the third generation of flow injection analysis. Trends Anal. Chem. 2003, 22, 225-231.
    • (2003) Trends Anal. Chem. , vol.22 , pp. 225-231
    • Wang, J.-H.1    Hansen, E.H.2
  • 26
    • 0344687425 scopus 로고    scopus 로고
    • On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS
    • Wang, J.-H.; Hansen, E.H. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS. Trends Anal. Chem. 2003, 22, 836-846.
    • (2003) Trends Anal. Chem. , vol.22 , pp. 836-846
    • Wang, J.-H.1    Hansen, E.H.2
  • 27
    • 0037325314 scopus 로고    scopus 로고
    • Exploiting the bead-injection approach in the integrated sequential injection Lab-on-Valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior to ETAAS detection
    • Miró, M.; Jónczyk, S.; Wang, J.-H.; Hansen, E.H. Exploiting the bead-injection approach in the integrated sequential injection Lab-on-Valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior to ETAAS detection. J. Anal. At. Spectrom. 2003, 18, 89-98.
    • (2003) J. Anal. At. Spectrom. , vol.18 , pp. 89-98
    • Miró, M.1    Jónczyk, S.2    Wang, J.-H.3    Hansen, E.H.4
  • 28
    • 4544330176 scopus 로고    scopus 로고
    • Evaluation of a novel PTFE material for use as a means for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems. Determination of cadmium (II) with detection by electrothermal atomic absorption spectrometry (ETAAS)
    • Long, X.B.; Chomchoei, R.; Gala, P.; Hansen, E.H. Evaluation of a novel PTFE material for use as a means for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems. Determination of cadmium (II) with detection by electrothermal atomic absorption spectrometry (ETAAS). Anal. Chim. Acta 2004, 523, 279-286.
    • (2004) Anal. Chim. Acta , vol.523 , pp. 279-286
    • Long, X.B.1    Chomchoei, R.2    Gala, P.3    Hansen, E.H.4
  • 29
    • 0034661945 scopus 로고    scopus 로고
    • Equilibrium and kinetic measurements of muscarinic receptor antagonism on living cells using bead injection spectroscopy
    • Hodder, P. S.; Beeson, C.; Ruzicka, J. Equilibrium and kinetic measurements of muscarinic receptor antagonism on living cells using bead injection spectroscopy. Anal. Chem. 2000, 72, 3109-3115.
    • (2000) Anal. Chem. , vol.72 , pp. 3109-3115
    • Hodder, P.S.1    Beeson, C.2    Ruzicka, J.3
  • 30
    • 0036320912 scopus 로고    scopus 로고
    • Microsequential injection: Anion separations using "Lab-on- Valve" coupled with capillary electrophoresis
    • Wu C.-H.; Scampavia, L.; Ruzicka, J. Microsequential injection: anion separations using "Lab-on-Valve" coupled with capillary electrophoresis. Analyst 2002, 127, 898-905.
    • (2002) Analyst , vol.127 , pp. 898-905
    • Wu, C.-H.1    Scampavia, L.2    Ruzicka, J.3
  • 31
    • 8444234030 scopus 로고    scopus 로고
    • Utilizing a sequential injection system furnished with an extraction microcolumn as a novel approach for executing sequential extractions of metal species in solid samples
    • Chomchoei, R.; Hansen, E.H.; Shiowatana, J. Utilizing a sequential injection system furnished with an extraction microcolumn as a novel approach for executing sequential extractions of metal species in solid samples. Anal. Chim. Acta 2004, 526, 177-184.
    • (2004) Anal. Chim. Acta , vol.526 , pp. 177-184
    • Chomchoei, R.1    Hansen, E.H.2    Shiowatana, J.3
  • 32
    • 17144416810 scopus 로고    scopus 로고
    • Sequential injection system incorporating a micro extraction column for automatic fractionation of metal ions in solid samples. Comparison of the extraction profiles when employing uni-, bi-, and multi bidirectional flow plus stopped-flow
    • Chomchoei, R.; Miro, M.; Hansen, E.H.; Shiowatana, J. Sequential injection system incorporating a micro extraction column for automatic fractionation of metal ions in solid samples. Comparison of the extraction profiles when employing uni-, bi-, and multi bidirectional flow plus stopped-flow. Anal. Chim. Acta 2005, 536, 183-197.
    • (2005) Anal. Chim. Acta , vol.536 , pp. 183-197
    • Chomchoei, R.1    Miro, M.2    Hansen, E.H.3    Shiowatana, J.4
  • 33
    • 18144422043 scopus 로고    scopus 로고
    • An automated sequential injection microcolumn approach with on-line atomic spectrometric detection for implementing metal fractionation schemes of homogeneous and non-homogeneous solid samples of environmental interest
    • Chomchoei, R.; Miró, M.; Hansen, E.H.; Shiowatana, J. An automated sequential injection microcolumn approach with on-line atomic spectrometric detection for implementing metal fractionation schemes of homogeneous and non-homogeneous solid samples of environmental interest. Anal. Chem. 2005, 77, 2720-2726.
    • (2005) Anal. Chem. , vol.77 , pp. 2720-2726
    • Chomchoei, R.1    Miró, M.2    Hansen, E.H.3    Shiowatana, J.4
  • 34
    • 7044272235 scopus 로고    scopus 로고
    • The impact of flow injection on modern chemical analysis: Has it fulfilled our expectations? And where are we going?
    • Hansen, E.H. The impact of flow injection on modern chemical analysis: has it fulfilled our expectations? And where are we going? Talanta 2004, 64, 1076-1083.
    • (2004) Talanta , vol.64 , pp. 1076-1083
    • Hansen, E.H.1
  • 35
    • 0030824578 scopus 로고    scopus 로고
    • Use of single and sequential chemical extractants to assess radionuclide and heavy metal availability from soils for root uptake
    • Kennedy, V.H.; Sanchez, A.L.; Oughton, D.H.; Rowland, A.P. Use of single and sequential chemical extractants to assess radionuclide and heavy metal availability from soils for root uptake. Analyst 1997, 122, 89R-100R.
    • (1997) Analyst , vol.122
    • Kennedy, V.H.1    Sanchez, A.L.2    Oughton, D.H.3    Rowland, A.P.4
  • 36
    • 0033802015 scopus 로고    scopus 로고
    • Application of a modified BCR sequential extraction (three-step) procedure for the determination of extractable trace metal contents in a sewage sludge amended soil reference material (CRM 483), complemented by a three-year study of acetic acid and EDTA extractable metal content
    • Rauret, G.; López-Sánchez, J. F.; Sahuquillo, A.; Barahona, E.; Lachica, M.; Ure, A. M.; Davidson, C. M.; Gomez, A.; Lück, D.; Bacon, J.; Yli-Halla, M.; Muntau, H.; Quevauviller, Ph. Application of a modified BCR sequential extraction (three-step) procedure for the determination of extractable trace metal contents in a sewage sludge amended soil reference material (CRM 483), complemented by a three-year study of acetic acid and EDTA extractable metal content. J. Environ. Monit. 2002, 2, 228-233.
    • (2002) J. Environ. Monit. , vol.2 , pp. 228-233
    • Rauret, G.1    López-Sánchez, J.F.2    Sahuquillo, A.3    Barahona, E.4    Lachica, M.5    Ure, A.M.6    Davidson, C.M.7    Gomez, A.8    Lück, D.9    Bacon, J.10    Yli-Halla, M.11    Muntau, H.12    Quevauviller, P.13


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.