메뉴 건너뛰기




Volumn 14, Issue 4, 2005, Pages 241-244

Comparison of erythrocyte sedimentation rate measurement by the automated SEDIsystem™ and conventional Westergren method using the Bland and Altman statistical method

Author keywords

Erythrocyte sedimentation rate; SEDIsystem ; Westergren method

Indexed keywords

ARTICLE; AUTOANALYZER; BLOOD SAMPLING; CONFIDENCE INTERVAL; CONTROLLED STUDY; ERYTHROCYTE SEDIMENTATION RATE; HUMAN; INTERMETHOD COMPARISON; LABORATORY AUTOMATION; LABORATORY TEST; LINEAR REGRESSION ANALYSIS; RANDOMIZATION; REFERENCE VALUE; STATISTICAL ANALYSIS;

EID: 20844451064     PISSN: 10117571     EISSN: None     Source Type: Journal    
DOI: 10.1159/000085742     Document Type: Article
Times cited : (15)

References (13)
  • 1
    • 84980090104 scopus 로고
    • Studies of the suspension stability of the blood in pulmonary tuberculosis
    • Westergren A: Studies of the suspension stability of the blood in pulmonary tuberculosis. Acta Med Scand 1921;54:247-282.
    • (1921) Acta Med Scand , vol.54 , pp. 247-282
    • Westergren, A.1
  • 2
    • 0027523321 scopus 로고
    • ICSH recommendations for measurement of erythrocyte sedimentation rate
    • International Council for Standardization in Haematology: ICSH recommendations for measurement of erythrocyte sedimentation rate. J Clin Pathol. 1993;46:198-203.
    • (1993) J Clin Pathol , vol.46 , pp. 198-203
  • 4
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;i:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 0028721966 scopus 로고
    • Kinetic measurement of the erythrocyte sedimentation rate
    • Kallner A, Engervall P, Bjorkholm M: Kinetic measurement of the erythrocyte sedimentation rate. Ups J Med Sci 1994;99:179-186.
    • (1994) Ups J Med Sci , vol.99 , pp. 179-186
    • Kallner, A.1    Engervall, P.2    Bjorkholm, M.3
  • 7
    • 0031751206 scopus 로고    scopus 로고
    • The Test 1 automated system: A new method for measuring the erythrocyte sedimentation rate
    • Plebani M, De Toni S, Sanzari MC, Bernadi D, Stochreiter E: The Test 1 automated system: A new method for measuring the erythrocyte sedimentation rate. Am J Clin Pathol 1998;110:334-340.
    • (1998) Am J Clin Pathol , vol.110 , pp. 334-340
    • Plebani, M.1    De Toni, S.2    Sanzari, M.C.3    Bernadi, D.4    Stochreiter, E.5
  • 8
    • 0033381399 scopus 로고    scopus 로고
    • Comparison of the erythrocyte sedimentation rate measured in the eye casualty department by the Seditainer method with an automated system
    • Browning AC, Burbidge AA, Hodgkins PR: Comparison of the erythrocyte sedimentation rate measured in the eye casualty department by the Seditainer method with an automated system. Eye 1999;13:754-757.
    • (1999) Eye , vol.13 , pp. 754-757
    • Browning, A.C.1    Burbidge, A.A.2    Hodgkins, P.R.3
  • 9
    • 0036306305 scopus 로고    scopus 로고
    • Validation of the Diesse Mini-Ves erythrocyte sedimentation rate (ESR) analyser using the Westergren ESR method in patients with systemic inflammatory conditions
    • Happe MR, Battafarano DF, Dooly DP, Rennie TA, Murphy FT, Casey TJ, Ward JA: Validation of the Diesse Mini-Ves erythrocyte sedimentation rate (ESR) analyser using the Westergren ESR method in patients with systemic inflammatory conditions. Am J Clin Pathol 2002;118:14-17.
    • (2002) Am J Clin Pathol , vol.118 , pp. 14-17
    • Happe, M.R.1    Battafarano, D.F.2    Dooly, D.P.3    Rennie, T.A.4    Murphy, F.T.5    Casey, T.J.6    Ward, J.A.7
  • 10
    • 0037228325 scopus 로고    scopus 로고
    • Length of sedimentation reaction in blood: A comparison of the test 1 ESR system with the ICSH reference method and the SEDIsystem 15
    • Romero A, Munoz M, Ramirez G: Length of sedimentation reaction in blood: A comparison of the test 1 ESR system with the ICSH reference method and the SEDIsystem 15. Clin Chem Lab Med 2003;41:115-116.
    • (2003) Clin Chem Lab Med , vol.41 , pp. 115-116
    • Romero, A.1    Munoz, M.2    Ramirez, G.3
  • 11
    • 0031912143 scopus 로고    scopus 로고
    • Automated measurement of erythrocyte sedimentation rate and its relation to red blood cell concentration and plasma proteins
    • Imafuku Y, Yoshida H, Greenfield S, Rabinovitch A: Automated measurement of erythrocyte sedimentation rate and its relation to red blood cell concentration and plasma proteins. Hematol Cell Ther 1998;40:27-32.
    • (1998) Hematol Cell Ther , vol.40 , pp. 27-32
    • Imafuku, Y.1    Yoshida, H.2    Greenfield, S.3    Rabinovitch, A.4
  • 12
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland JM, Altman DG: Comparing methods of measurement: Why plotting difference against standard method is misleading. Lancet 1995;346:1085-1087.
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 0036224912 scopus 로고    scopus 로고
    • Application of the Bland-Altman plot for interpretation of methods - Comparison studies: A critical investigation of its practice
    • Dewitte K, Fierens C, Stockl D, Thienpont LM: Application of the Bland-Altman plot for interpretation of methods - comparison studies: A critical investigation of its practice. Clin Chem 2002;48:799-801.
    • (2002) Clin Chem , vol.48 , pp. 799-801
    • Dewitte, K.1    Fierens, C.2    Stockl, D.3    Thienpont, L.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.