메뉴 건너뛰기




Volumn 29, Issue 11, 2005, Pages 44-48

Study on current development situation and implementation strategy of real-time dynamic monitoring system in power systems in China

Author keywords

Phasor measurement unit (PMU); Power system; Real time dynamic monitoring; Wide area measurement system (WAMS)

Indexed keywords

DYNAMICS; ELECTRIC POWER SYSTEMS; ELECTRIC SUBSTATIONS; MONITORING;

EID: 20744445370     PISSN: 10003673     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (15)
  • 1
    • 20744446427 scopus 로고    scopus 로고
    • Chinese source
  • 3
    • 20744454887 scopus 로고    scopus 로고
    • Chinese source
  • 4
    • 0142238599 scopus 로고    scopus 로고
    • Development of multi-function real time power angle monitoring system for East China power grid and its application
    • [J]
    • Wang Zhaojia, Cen Zonghao, Chen Hanzhong. Development of multi-function real time power angle monitoring system for East China power grid and its application[J]. Power System Technology, 2002, 26(8): 73-77.
    • (2002) Power System Technology , vol.26 , Issue.8 , pp. 73-77
    • Wang, Z.1    Cen, Z.2    Chen, H.3
  • 5
    • 0035517532 scopus 로고    scopus 로고
    • The validity study of Prony analysis for low frequency oscillation in power system
    • [J]
    • Wang Tieqiang, He Renmu, Xu Dongjiee et al. The validity study of Prony analysis for low frequency oscillation in power system [J]. Electric Power, 2001, 34(11): 38-41.
    • (2001) Electric Power , vol.34 , Issue.11 , pp. 38-41
    • Wang, T.1    He, R.2    Xu, D.3
  • 6
    • 20744444848 scopus 로고    scopus 로고
    • Chinese source
  • 7
    • 2542491509 scopus 로고    scopus 로고
    • Wide-area dynamic security monitoring system for power network and its dynamic simulation
    • [J]
    • Xiao Jinyu, Xie Xiaorong, Li Jian et al. Wide-area dynamic security monitoring system for power network and its dynamic simulation [J]. Power System Technology, 2004, 28(6): 5-9.
    • (2004) Power System Technology , vol.28 , Issue.6 , pp. 5-9
    • Xiao, J.1    Xie, X.2    Li, J.3
  • 8
    • 1942507510 scopus 로고    scopus 로고
    • Inter-area damping control of interconnected power systems using wide-area measurements
    • [J]
    • Xie Xiaorong, Xiao Jinyu, Tong Luyuan et al. Inter-area damping control of interconnected power systems using wide-area measurements[J]. Automation of Electric Power Systems, 2004, 28(2): 37-40.
    • (2004) Automation of Electric Power Systems , vol.28 , Issue.2 , pp. 37-40
    • Xie, X.1    Xiao, J.2    Tong, L.3
  • 9
    • 12444338832 scopus 로고    scopus 로고
    • Power systems wide-area damping control based on online system identification
    • [J]
    • Xiao Jinyu, Xie Xiaorong, Hu Zhixiang et al. Power systems wide-area damping control based on online system identification [J]. Automation of Electric Power Systems, 2004, 28(23): 22-27.
    • (2004) Automation of Electric Power Systems , vol.28 , Issue.23 , pp. 22-27
    • Xiao, J.1    Xie, X.2    Hu, Z.3
  • 10
    • 2942676998 scopus 로고    scopus 로고
    • Coordination of out of step protection equipment in large power systems
    • [J]
    • Zong Hongliang, Sun Guanghui, Liu Zhi et al. Coordination of out of step protection equipment in large power systems[J]. Automation of Electric Power Systems, 2003, 27(22): 72-75.
    • (2003) Automation of Electric Power Systems , vol.27 , Issue.22 , pp. 72-75
    • Zong, H.1    Sun, G.2    Liu, Z.3
  • 11
    • 0028196385 scopus 로고
    • Synchronized sampling and phasor measurements for relaying and control
    • [J]
    • Phadke A G, Pickett B, Adamiak M et al. Synchronized sampling and phasor measurements for relaying and control[J]. IEEE Trans on Power Delivery, 1994, 9(1): 442-452.
    • (1994) IEEE Trans on Power Delivery , vol.9 , Issue.1 , pp. 442-452
    • Phadke, A.G.1    Pickett, B.2    Adamiak, M.3
  • 12
    • 0025505722 scopus 로고
    • A predictive out-of-step protection system based on observation of the phase difference between substation
    • [J]
    • Ohura Y, Suzuki M, Yanagihashi K et al. A predictive out-of-step protection system based on observation of the phase difference between substation [J]. IEEE Trans on Power Delivery, 1990, 5(4): 1695-1704.
    • (1990) IEEE Trans on Power Delivery , vol.5 , Issue.4 , pp. 1695-1704
    • Ohura, Y.1    Suzuki, M.2    Yanagihashi, K.3
  • 13
    • 2542488596 scopus 로고    scopus 로고
    • Feasibility study on using synchrophasor technology for power system transient stability control
    • [J]
    • Xie Xiaorong, Li Hongjun, Wu Jingtao et al. Feasibility study on using synchrophasor technology for power system transient stability control[J]. Power System Technology, 2004, 28(1): 10-14.
    • (2004) Power System Technology , vol.28 , Issue.1 , pp. 10-14
    • Xie, X.1    Li, H.2    Wu, J.3
  • 14
    • 4744353901 scopus 로고    scopus 로고
    • Real-time communication in a synchronous states monitoring system for wide area power systems
    • [J]
    • Li Gang, Wang Shaorong, Cheng Shijie. Real-time communication in a synchronous states monitoring system for wide area power systems[J]. Power System Technology, 2004, 28(18): 39-43.
    • (2004) Power System Technology , vol.28 , Issue.18 , pp. 39-43
    • Li, G.1    Wang, S.2    Cheng, S.3
  • 15
    • 10844250325 scopus 로고    scopus 로고
    • Wide-area real time dynamic security monitoring system of North China power grid
    • [J]
    • Li Dan, Han Fukun, Quo Ziming et al. Wide-area real time dynamic security monitoring system of North China power grid[J]. Power System Technology, 2004, 28(23): 52-56.
    • (2004) Power System Technology , vol.28 , Issue.23 , pp. 52-56
    • Li, D.1    Han, F.2    Quo, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.