메뉴 건너뛰기




Volumn 12, Issue 2, 2005, Pages 223-239

PD knowledge rules for insulation condition assessment of distribution power cables

Author keywords

Condition assessment; Decision support; On site diagnosis; Partial discharges; Power cables

Indexed keywords

DATABASE SYSTEMS; ELECTRIC BREAKDOWN; ELECTRIC INSULATION; ELECTRIC NETWORK ANALYSIS; ELECTRIC POWER DISTRIBUTION; PARTIAL DISCHARGES;

EID: 20744444575     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2005.1430393     Document Type: Article
Times cited : (38)

References (24)
  • 1
    • 20744443780 scopus 로고
    • On-site testing of extruded power cables by PD measurements at SI voltages
    • Vienna, Paper 1020-02
    • E. Lemke, R. Röding and W. Weißenberg, "On-site Testing of Extruded Power Cables by PD Measurements at SI Voltages", CIGRE Symp, Vienna, Paper 1020-02, 1987.
    • (1987) CIGRE Symp
    • Lemke, E.1    Röding, R.2    Weißenberg, W.3
  • 3
    • 20744452035 scopus 로고
    • Comparative study on alternative test Voltages for laid medium voltage cables
    • Dresden, Germany, CIGRE, Paper 4.3
    • R. Bach and W. Kalkner, "Comparative Study on Alternative Test Voltages for Laid Medium Voltage Cables", 7th ISH, Dresden, Germany, CIGRE, Paper 4.3, 1991.
    • (1991) 7th ISH
    • Bach, R.1    Kalkner, W.2
  • 5
    • 20744446721 scopus 로고
    • Complex Discharge Analysing (CDA) - An alternative procedure for diagnosis tests of HV power apparatus of extremely high capacity
    • Graz, Austria, Paper 5617
    • E. Lemke and P. Schmiegel, "Complex Discharge Analysing (CDA) - An Alternative Procedure for Diagnosis Tests of HV Power Apparatus of Extremely High Capacity", 9th ISH, Graz, Austria, Paper 5617, 1995.
    • (1995) 9th ISH
    • Lemke, E.1    Schmiegel, P.2
  • 6
    • 20744456879 scopus 로고
    • A very low frequency high voltage generator for testing cables after laying
    • Braunschweig, Germany, Paper 1.28
    • W. Boone, G.C. Damstra, W.J.L. Jansen and C. de Ligt, "A Very Low Frequency High Voltage Generator for Testing Cables After Laying", 5th ISH, Braunschweig, Germany, Paper 1.28, 1987.
    • (1987) 5th ISH
    • Boone, W.1    Damstra, G.C.2    Jansen, W.J.L.3    De Ligt, C.4
  • 9
    • 0003282602 scopus 로고    scopus 로고
    • Vergleich von Diagnosesystemen zur Beurteilung des Alterungszustandes PE/VPE-isolierter Mittelspannungskabel
    • R. Plath, W. Kalkner and I. Krage, "Vergleich von Diagnosesystemen zur Beurteilung des Alterungszustandes PE/VPE-isolierter Mittelspannungskabel", Elektr. Wirtschaft, Vol. 96, pp. 1130-1140, 1997.
    • (1997) Elektr. Wirtschaft , vol.96 , pp. 1130-1140
    • Plath, R.1    Kalkner, W.2    Krage, I.3
  • 11
    • 0035197060 scopus 로고    scopus 로고
    • PD inception conditions and PD pattern of defects in PILC
    • Y. Muramoto, E. Gulski, F.J. Wester and J.J. Smit, "PD Inception Conditions and PD Pattern of Defects in PILC", IEEE 7th ICSD, pp. 369-372, 2001.
    • (2001) IEEE 7th ICSD , pp. 369-372
    • Muramoto, Y.1    Gulski, E.2    Wester, F.J.3    Smit, J.J.4
  • 13
    • 0037721682 scopus 로고    scopus 로고
    • CBM of MV power cable systems on the base of advanced PD diagnosis
    • Amsterdam, The Netherlands, Paper No. 1.29
    • F.J. Wester, E. Gulski and J.J. Smit, "CBM of MV Power Cable Systems on the Base of Advanced PD Diagnosis", 16th Int. Conf. Electricity Distribution (CIRED), Amsterdam, The Netherlands, Paper No. 1.29, 2001.
    • (2001) 16th Int. Conf. Electricity Distribution (CIRED)
    • Wester, F.J.1    Gulski, E.2    Smit, J.J.3
  • 14
    • 0029710602 scopus 로고    scopus 로고
    • Procedure for evaluation of dielectric properties based on complex Discharge Analyzing (CDA)
    • Montreal, Canada
    • E. Lemke, P. Schmiegel, H. Elze and D. Rußwurm, "Procedure for Evaluation of Dielectric Properties Based on Complex Discharge Analyzing (CDA)", IEEE Intern. Symp. Electr. Insul. (ISEI), Montreal, Canada, pp. 385-388, 1996.
    • (1996) IEEE Intern. Symp. Electr. Insul. (ISEI) , pp. 385-388
    • Lemke, E.1    Schmiegel, P.2    Elze, H.3    Rußwurm, D.4
  • 15
    • 0033885928 scopus 로고    scopus 로고
    • Advanced PD diagnosis of MV power cables using oscillating wave test system
    • E. Gulski, F.J. Wester, J.J. Smit, P.N. Seitz and M. Turner, "Advanced PD Diagnosis of MV Power Cables using Oscillating Wave Test System", IEEE Electr. Insul. Magazine, Vol. 16, No. 2, pp. 17-25, 2000.
    • (2000) IEEE Electr. Insul. Magazine , vol.16 , Issue.2 , pp. 17-25
    • Gulski, E.1    Wester, F.J.2    Smit, J.J.3    Seitz, P.N.4    Turner, M.5
  • 16
    • 20744456722 scopus 로고
    • A very low frequency 200 kV generator as a precondition for testing insulating materials with 0.1 Hz AC voltage
    • Athens, Greece
    • P. Groenefeld and R.v. Ohlhausen, "A Very Low Frequency 200 kV Generator as a Precondition for Testing Insulating Materials with 0.1 Hz AC Voltage", 4th ISH Symposium, Athens, Greece, pp. 7-15, 1983.
    • (1983) 4th ISH Symposium , pp. 7-15
    • Groenefeld, P.1    Ohlhausen, R.V.2
  • 17
    • 20744445338 scopus 로고    scopus 로고
    • Datamining and information processing to support the AM decision making process
    • London, UK
    • B. Quak, E. Gulski and J.J. Smit, "Datamining and Information Processing to Support the AM Decision Making Process", ERA Conf. Engineering Asset Management, London, UK, 2002.
    • (2002) ERA Conf. Engineering Asset Management
    • Quak, B.1    Gulski, E.2    Smit, J.J.3
  • 21
    • 0024881557 scopus 로고
    • Dielectric test with oscillating discharge on synthetic insulation cables
    • Paris, France
    • Lefèvre, W. Legros and W. Salvador, "Dielectric Test with Oscillating Discharge on Synthetic Insulation Cables, Int. Conf. Electricity Distribution (CIRED), Paris, France, pp. 270-273, 1989.
    • (1989) Int. Conf. Electricity Distribution (CIRED) , pp. 270-273
    • Legros, L.W.1    Salvador, W.2
  • 22
    • 0036075462 scopus 로고    scopus 로고
    • Recent field experiments in PD assessment of power cables, using oscillating voltage waveforms
    • S. Brettschneider, E. Lemke, J.L. Hinkle and M. Schneider, "Recent Field Experiments in PD Assessment of Power Cables, Using Oscillating Voltage Waveforms", IEEE ISEI, pp. 546-552, 2002.
    • (2002) IEEE ISEI , pp. 546-552
    • Brettschneider, S.1    Lemke, E.2    Hinkle, J.L.3    Schneider, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.