메뉴 건너뛰기




Volumn 23, Issue 4, 2005, Pages 441-448

Cylindrical micro touch sensor with a piezoelectric thin film for microbial separation

Author keywords

Microorganism; Microsensor; Piezoelectric thin film; Pipette; Screening; Separation; Touch sensor

Indexed keywords

MICROORGANISM; PIEZOELECTRIC THIN FILMS; PIPETTES; TOUCH SENSORS;

EID: 20744444413     PISSN: 02635747     EISSN: None     Source Type: Journal    
DOI: 10.1017/S0263574704000876     Document Type: Article
Times cited : (3)

References (26)
  • 1
    • 0035011841 scopus 로고    scopus 로고
    • Review: Single-cell sorting of microorganisms by flow or slide-based (including laser scanning) cytometry
    • T. Katsuragi and Y. Tani, "Review: Single-cell sorting of microorganisms by flow or slide-based (including laser scanning) cytometry", Acta Biotechnol. 21, 99-115 (2001).
    • (2001) Acta Biotechnol. , vol.21 , pp. 99-115
    • Katsuragi, T.1    Tani, Y.2
  • 3
    • 0025794626 scopus 로고
    • Linear motion of dielectric particles and living cells in microfabricated structures induced by traveling electric fields
    • G. Fuhr, R. Hagedorn, T. Mueller, B. Wagner and W. Benecke, "Linear Motion of Dielectric Particles and Living Cells in Microfabricated Structures Induced by Traveling Electric Fields", Proc. IEEE MEMS (1991) pp. 259-264.
    • (1991) Proc. IEEE MEMS , pp. 259-264
    • Fuhr, G.1    Hagedorn, R.2    Mueller, T.3    Wagner, B.4    Benecke, W.5
  • 4
    • 0345493749 scopus 로고    scopus 로고
    • Paired microelectrode system: Dielectrophoretic particle sorting and force calibration
    • T. Schnelle et al., "Paired Microelectrode System: Dielectrophoretic Particle Sorting and Force Calibration", J. of Electrostatics 47, 121-132 (1999).
    • (1999) J. of Electrostatics , vol.47 , pp. 121-132
    • Schnelle, T.1
  • 5
    • 0008538109 scopus 로고    scopus 로고
    • Rare event cell sorting in a microfluidic system for application in prenatal diagnosis
    • A. Wolff et al., "Rare Event Cell Sorting in a Microfluidic System for Application in Prenatal Diagnosis", Proc. of the Micro Total Analysis Systems (μ-TAS1998) (1998) pp. 77-80.
    • (1998) Proc. of the Micro Total Analysis Systems (μ-TAS1998) , pp. 77-80
    • Wolff, A.1
  • 6
    • 0036646674 scopus 로고    scopus 로고
    • Development of a microfluidic device for fluorescence activated cell sorting
    • J. Krueger et al., "Development of a Microfluidic Device for Fluorescence Activated Cell Sorting", J. Micromech. Microeng. 12, 486-494 (2002).
    • (2002) J. Micromech. Microeng. , vol.12 , pp. 486-494
    • Krueger, J.1
  • 7
    • 0035142860 scopus 로고    scopus 로고
    • High speed separation system of randomly suspended single living cells by laser trap and dielectrophoresis
    • F. Arai, A. Ichikawa, M. Ogawa, T. Fukuda, K. Horio and K. Itoigawa, "High Speed Separation System of Randomly Suspended Single Living Cells by Laser Trap and Dielectrophoresis", Electrophoresis 22, No. 2, 283-288 (2001).
    • (2001) Electrophoresis , vol.22 , Issue.2 , pp. 283-288
    • Arai, F.1    Ichikawa, A.2    Ogawa, M.3    Fukuda, T.4    Horio, K.5    Itoigawa, K.6
  • 8
    • 0038501540 scopus 로고    scopus 로고
    • Separation of target microbe by laser manipulation and flow control
    • F. Arai, A. Ichikawa et al., "Separation of Target Microbe by Laser Manipulation and Flow Control", Journal of Robotics and Mechatronics 14, No. 2, 133-139 (2002).
    • (2002) Journal of Robotics and Mechatronics , vol.14 , Issue.2 , pp. 133-139
    • Arai, F.1    Ichikawa, A.2
  • 12
    • 0029349886 scopus 로고
    • Resonator-based touch-sensitive probe
    • S. M. Harb and M. Vidic, "Resonator-based Touch-Sensitive Probe", Sensors and Actuators A50, 23-29 (1995).
    • (1995) Sensors and Actuators , vol.A50 , pp. 23-29
    • Harb, S.M.1    Vidic, M.2
  • 13
    • 0032733299 scopus 로고    scopus 로고
    • Self-exited piezoelectric PZT microcantilevers for dynamic SFM - With inherent sensing and actuating capabilities
    • C. Lee, T. Itoh and T. Suga, "Self-exited Piezoelectric PZT Microcantilevers for Dynamic SFM - with Inherent Sensing and Actuating Capabilities", Sensors and Actuators A72, 179-188 (1999).
    • (1999) Sensors and Actuators , vol.A72 , pp. 179-188
    • Lee, C.1    Itoh, T.2    Suga, T.3
  • 14
    • 0037187241 scopus 로고    scopus 로고
    • Non-contact atomic force microscope with a PZT cantilever used for deflection sensing, direct oscillation and feedback actuation
    • Y. Miyahara, M. Descheler, T. Fujii, S. Wataneba and H. Bleuler, "Non-contact Atomic Force Microscope with a PZT Cantilever Used for Deflection Sensing, Direct Oscillation and Feedback Actuation", Applied Surface Science 188, 450-455 (2002).
    • (2002) Applied Surface Science , vol.188 , pp. 450-455
    • Miyahara, Y.1    Descheler, M.2    Fujii, T.3    Wataneba, S.4    Bleuler, H.5
  • 16
    • 0034872322 scopus 로고    scopus 로고
    • Mechanical micro-dissection by microknife using ultrasonic vibration and ultra fine touch probe sensor
    • F. Arai, T. Amano et al., "Mechanical Micro-dissection by Microknife Using Ultrasonic Vibration and Ultra Fine Touch Probe Sensor", Proc. 2001 IEEE Int. Conf. Robotics & Automation (2001) pp. 139-144.
    • (2001) Proc. 2001 IEEE Int. Conf. Robotics & Automation , pp. 139-144
    • Arai, F.1    Amano, T.2
  • 19
    • 0027664417 scopus 로고
    • Analysis of bending displacement of lead zirconate titanate thin film synthesized by hydrothermal method
    • Y. Ohba, M. Miyauchi, T. Tsurumi and M. Daimon, "Analysis of Bending Displacement of Lead Zirconate Titanate Thin Film Synthesized by Hydrothermal Method", Jpn. J. of Appl. Phys. 32, 4095-4098 (1993).
    • (1993) Jpn. J. of Appl. Phys. , vol.32 , pp. 4095-4098
    • Ohba, Y.1    Miyauchi, M.2    Tsurumi, T.3    Daimon, M.4
  • 20
    • 0032155478 scopus 로고    scopus 로고
    • A cylindrical micro ultrasonic motor using PZT thin film deposited by single process hydrothermal method (φ 2.4mm, L = 10mm stator transducer)
    • T. Morita, M. K. Kurosawa and T. Higuchi, "A Cylindrical Micro Ultrasonic Motor Using PZT Thin Film Deposited by Single Process Hydrothermal Method (φ 2.4mm, L = 10mm Stator Transducer)", IEEE Transaction on Ultrasonics, Ferroelectrics, and Frequency Control 45, No. 5, 1178-1187 (1998).
    • (1998) IEEE Transaction on Ultrasonics, Ferroelectrics, and Frequency Control , vol.45 , Issue.5 , pp. 1178-1187
    • Morita, T.1    Kurosawa, M.K.2    Higuchi, T.3
  • 21
    • 0031619737 scopus 로고    scopus 로고
    • Parallel beam micro sensor/actuator unit using PZT thin films and application examples
    • T. Fukuda, H. Sato, F. Arai, H. Iwata and K. Itoigawa, "Parallel Beam Micro Sensor/Actuator Unit Using PZT Thin Films and Application Examples", Proceedings of the IEEE ICRA (1998) Vol. 2, pp. 1498-1503.
    • (1998) Proceedings of the IEEE ICRA , vol.2 , pp. 1498-1503
    • Fukuda, T.1    Sato, H.2    Arai, F.3    Iwata, H.4    Itoigawa, K.5
  • 22
    • 0038163018 scopus 로고    scopus 로고
    • Fixation and isolation of microorganisms by local viscosity control of methyl cellulose solution
    • F. Arai, A. Ichikawa et al., "Fixation and Isolation of Microorganisms by Local Viscosity Control of Methyl Cellulose Solution", Procs. of the Micro Total Analysis Systems (μ-TAS2002) (2002) pp. 928-930.
    • (2002) Procs. of the Micro Total Analysis Systems (μ-TAS2002) , pp. 928-930
    • Arai, F.1    Ichikawa, A.2
  • 23
    • 0037480718 scopus 로고    scopus 로고
    • High throughput separation of microorganisms by pinpoint gelation controlled by local heating for parallel incubation on a chip
    • Kyoto
    • F. Arai, A. Ichikawa et al., "High Throughput Separation of Microorganisms by Pinpoint Gelation Controlled by Local Heating for Parallel Incubation on a Chip", Procs. IEEE MEMS-03 Kyoto (2003) pp. 219-222.
    • (2003) Procs. IEEE MEMS-03 , pp. 219-222
    • Arai, F.1    Ichikawa, A.2
  • 24
    • 0038121543 scopus 로고    scopus 로고
    • Isolation and extraction of target microbes using thermal sol-gel transformation
    • F. Arai, A. Ichikawa et al., "Isolation and extraction of target microbes using thermal sol-gel transformation", Analyst 128, 547-551 (2003).
    • (2003) Analyst , vol.128 , pp. 547-551
    • Arai, F.1    Ichikawa, A.2
  • 25
    • 0038501539 scopus 로고    scopus 로고
    • 3D calibration for micro-manipulation with precise position measurement
    • A. Kawaji, F. Arai and T. Fukuda, "3D Calibration for Micro-manipulation with Precise Position Measurement", J. of Micromechatronics 1, No. 2, 117-130 (2001).
    • (2001) J. of Micromechatronics , vol.1 , Issue.2 , pp. 117-130
    • Kawaji, A.1    Arai, F.2    Fukuda, T.3
  • 26
    • 3042539494 scopus 로고    scopus 로고
    • Continuous culture and monitoring of selected and isolated microorganisms on a chip by thermal gelation
    • F. Arai, A. Ichikawa et al., "Continuous Culture and Monitoring of Selected and Isolated Microorganisms on a Chip by Thermal Gelation", Procs. of the Micro Total Analysis Systems (μ-TAS2003) (2003) pp. 757-760.
    • (2003) Procs. of the Micro Total Analysis Systems (μ-TAS2003) , pp. 757-760
    • Arai, F.1    Ichikawa, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.