메뉴 건너뛰기




Volumn 16, Issue 3, 2005, Pages 430-435

A novel method for measuring and monitoring monobloc distraction osteogenesis using three-dimensional computed tomography rendered images with the 'biporion-dorsum sellae' plane. Part I: Precision and reproducibility

Author keywords

Biporion dorsum sellae plane; Monobloc distraction osteogenesis

Indexed keywords

ACCURACY; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DISTRACTION OSTEOGENESIS; FACIAL BONE; HUMAN; HUMAN EXPERIMENT; NORMAL HUMAN; PRIORITY JOURNAL; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING;

EID: 20744436982     PISSN: 10492275     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.SCS.0000147387.60875.77     Document Type: Article
Times cited : (6)

References (6)
  • 1
    • 0018095551 scopus 로고
    • Advancement of the orbits and the midface in one piece, combined with frontal repositioning, for the correction of Crouzon's deformities
    • Ortiz-Monasterio F, Fuente del Campo A, Carrillo A. Advancement of the orbits and the midface in one piece, combined with frontal repositioning, for the correction of Crouzon's deformities. Plast Reconstr Surg 1978;61(4):507-516
    • (1978) Plast Reconstr Surg , vol.61 , Issue.4 , pp. 507-516
    • Ortiz-Monasterio, F.1    Fuente Del Campo, A.2    Carrillo, A.3
  • 2
    • 85026148649 scopus 로고    scopus 로고
    • The accuracy of stereolithography in planning craniofacial bone replacement
    • Chang PS, Parker TH, Patrick CW Jr, Miller MJ. The accuracy of stereolithography in planning craniofacial bone replacement. J Craniofacial Surg 2003;14(2):164-170
    • (2003) J Craniofacial Surg , vol.14 , Issue.2 , pp. 164-170
    • Chang, P.S.1    Parker, T.H.2    Patrick Jr., C.W.3    Miller, M.J.4
  • 3
    • 0033947372 scopus 로고    scopus 로고
    • Standardization of 3-D CT measurements for length and angles by matrix transformation in the 3-D coordinate system
    • Kitaura H, Yonetsu K, Kitamori H, et al. Standardization of 3-D CT measurements for length and angles by matrix transformation in the 3-D coordinate system. Cleft Palate Craniofacial J 2000;37(4):349-356
    • (2000) Cleft Palate Craniofacial J , vol.37 , Issue.4 , pp. 349-356
    • Kitaura, H.1    Yonetsu, K.2    Kitamori, H.3
  • 4
    • 0024457657 scopus 로고
    • A method for three-dimensional image reformation for quantitative cephalometric analysis
    • Matteson SR, Bechtold W, Phillips C, Staab EV. A method for three-dimensional image reformation for quantitative cephalometric analysis. J Oral Maxillofac Surg 1989;47:1053-1061
    • (1989) J Oral Maxillofac Surg , vol.47 , pp. 1053-1061
    • Matteson, S.R.1    Bechtold, W.2    Phillips, C.3    Staab, E.V.4
  • 5
    • 0033032027 scopus 로고    scopus 로고
    • Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: Experimental validation in vitro
    • Cavalcanti MG, Haller JW, Vannier MW. Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: experimental validation in vitro. J Oral Maxillofac Surg 1999;57(6):690-694
    • (1999) J Oral Maxillofac Surg , vol.57 , Issue.6 , pp. 690-694
    • Cavalcanti, M.G.1    Haller, J.W.2    Vannier, M.W.3
  • 6
    • 0026587587 scopus 로고
    • Craniofacial skeletal measurements based on computed tomography: Part I. Accuracy and reproducibility
    • Waitzman AA, Posnick JC, Armstrong DC, Pron GE. Craniofacial skeletal measurements based on computed tomography: Part I. Accuracy and reproducibility. Cleft Palate Craniofacial J 1992;29(2):112-117
    • (1992) Cleft Palate Craniofacial J , vol.29 , Issue.2 , pp. 112-117
    • Waitzman, A.A.1    Posnick, J.C.2    Armstrong, D.C.3    Pron, G.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.