메뉴 건너뛰기




Volumn 24, Issue 6, 2005, Pages 712-718

Study of temporal stationarity and spatial consistency of fMRI noise using independent component analysis

Author keywords

Functional MRI (fMRI); Independent component analysis (ICA); Stationarity of structured noise

Indexed keywords

ACOUSTIC NOISE; BLOOD; CARDIOVASCULAR SYSTEM; DATA ACQUISITION; INDEPENDENT COMPONENT ANALYSIS; WAVELET TRANSFORMS;

EID: 20744436677     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2005.846852     Document Type: Article
Times cited : (23)

References (42)
  • 1
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • S. Ogawa, T. M. Lee, A. R. Kay, and D. W. Tank, "Brain magnetic resonance imaging with contrast dependent on blood oxygenation," Proc. Nat. Acad. Sci., vol. 87, pp. 9868-9872, 1990.
    • (1990) Proc. Nat. Acad. Sci. , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3    Tank, D.W.4
  • 3
    • 0000692808 scopus 로고
    • An investigation of the contribution of physiological noise in human functional MRI studies at 1.5 Tesla and 4 Tesla
    • New York
    • P. Jezzard, D. Le Bihan, C. Cuenod, L. Pannier, A. Prinster, and R. Turner, "An investigation of the contribution of physiological noise in human functional MRI studies at 1.5 Tesla and 4 Tesla," presented at the SMRM, 12th Annu. Meeting, New York, 1993.
    • (1993) SMRM, 12th Annu. Meeting
    • Jezzard, P.1    Le Bihan, D.2    Cuenod, C.3    Pannier, L.4    Prinster, A.5    Turner, R.6
  • 5
    • 0041193472 scopus 로고
    • Removal of physiological fluctuations from functional MRI signals
    • San Francisco, CA
    • B. Biswal, A. DeYoe, A. Jesmanowicz, and J. S. Hyde, "Removal of physiological fluctuations from functional MRI signals," presented at the SMR, 2nd Annu. Meeting, San Francisco, CA, 1994.
    • (1994) SMR, 2nd Annu. Meeting
    • Biswal, B.1    Deyoe, A.2    Jesmanowicz, A.3    Hyde, J.S.4
  • 7
    • 0030949562 scopus 로고    scopus 로고
    • The nature of spatiotemporal changes in cerebral hemodynamics as manifested in functional magnetic resonance imaging
    • P. P. Mitra, S. Ogawa, X. Hu, and K. Ugurbil, "The nature of spatiotemporal changes in cerebral hemodynamics as manifested in functional magnetic resonance imaging," Magn. Reson. Med., vol. 37, pp. 511-518, 1997.
    • (1997) Magn. Reson. Med. , vol.37 , pp. 511-518
    • Mitra, P.P.1    Ogawa, S.2    Hu, X.3    Ugurbil, K.4
  • 8
    • 20744459133 scopus 로고    scopus 로고
    • Physiological noise in functional magnetic resonance imaging and strategies for correction
    • Toronto, ON, Canada
    • G. Krueger, "Physiological noise in functional magnetic resonance imaging and strategies for correction," in Educational Course Syllabus ISMRM 11th Scientific Meeting, Toronto, ON, Canada, 2003.
    • (2003) Educational Course Syllabus ISMRM 11th Scientific Meeting
    • Krueger, G.1
  • 9
    • 0030710075 scopus 로고    scopus 로고
    • Assessment of flow and BOLD signals in resting-state functional connectivity map
    • Simultaneous
    • B. Biswal, J. VanKylen, and J. Hyde, "Assessment of flow and BOLD signals in resting-state functional connectivity map," NMR Biomed., vol. 10, pp. 165-170, 1997. Simultaneous.
    • (1997) NMR Biomed. , vol.10 , pp. 165-170
    • Biswal, B.1    Vankylen, J.2    Hyde, J.3
  • 10
    • 0036011151 scopus 로고    scopus 로고
    • Respiration-induced B0 fluctuations and their spatial distribution in the human brain at 7 Tesla
    • P.-F. Van de Moortele, J. Pheuffer, G. H. Glover, K. Ugurbil, and X. Hu, "Respiration-induced B0 fluctuations and their spatial distribution in the human brain at 7 Tesla," Magn. Reson. Med., vol. 47, pp. 888-895, 2002.
    • (2002) Magn. Reson. Med. , vol.47 , pp. 888-895
    • Van De Moortele, P.-F.1    Pheuffer, J.2    Glover, G.H.3    Ugurbil, K.4    Hu, X.5
  • 11
    • 0029166541 scopus 로고
    • Functional connectivity in the motor cortex of resting brain using echo-planar MRI
    • B. Biswal, F. Yetkin, V. M. Haughton, and J. S. Hyde, "Functional connectivity in the motor cortex of resting brain using echo-planar MRI," Magn. Resonan. Med., vol. 34, pp. 537-541, 1995.
    • (1995) Magn. Resonan. Med. , vol.34 , pp. 537-541
    • Biswal, B.1    Yetkin, F.2    Haughton, V.M.3    Hyde, J.S.4
  • 14
    • 20744446588 scopus 로고    scopus 로고
    • Investigating the frequency dependence of spatial gradient artifacts for the analysis of resting-state fMRI data
    • Toronto, ON, Canada
    • D. Cordes and R. R. Nandy, "Investigating the frequency dependence of spatial gradient artifacts for the analysis of resting-state fMRI data," presented at the ISMRM 11th Scientific Meeting, Toronto, ON, Canada, 2003.
    • (2003) ISMRM 11th Scientific Meeting
    • Cordes, D.1    Nandy, R.R.2
  • 15
    • 4344705249 scopus 로고
    • Statistical parametric maps in functional imaging: A general linear approach
    • K. Friston, A. Holmes, K. Worsley, J. Poline, C. Frith, and R. Frackowiak, "Statistical parametric maps in functional imaging: A general linear approach," Hum. Brain Map., vol. 2, pp. 189-210, 1995.
    • (1995) Hum. Brain Map. , vol.2 , pp. 189-210
    • Friston, K.1    Holmes, A.2    Worsley, K.3    Poline, J.4    Frith, C.5    Frackowiak, R.6
  • 16
    • 0030053163 scopus 로고    scopus 로고
    • Reduction of physiological fluctuations in fMRI using digital filters
    • B. Biswal, E. A. DeYoe, and J. S. Hyde, "Reduction of physiological fluctuations in fMRI using digital filters," Magn. Reson. Med., vol. 35, pp. 107-113, 1996.
    • (1996) Magn. Reson. Med. , vol.35 , pp. 107-113
    • Biswal, B.1    Deyoe, E.A.2    Hyde, J.S.3
  • 17
    • 0030885132 scopus 로고    scopus 로고
    • Noise suppression digital filter for functional magnetic resonance imaging based on image reference data
    • M. H. Buonocore and R. I. Maddock, "Noise suppression digital filter for functional magnetic resonance imaging based on image reference data," Magn. Reson. Med., vol. 38, pp. 456-469, 1997.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 456-469
    • Buonocore, M.H.1    Maddock, R.I.2
  • 18
    • 0033762153 scopus 로고    scopus 로고
    • Wavelet transform-based Wiener filtering of event-related fMRI data
    • S. M. LaConte, S.-C. Ngan, and X. Hu, "Wavelet transform-based Wiener filtering of event-related fMRI data," Magn. Reson. Med., vol. 44, pp. 746-757, 2000.
    • (2000) Magn. Reson. Med. , vol.44 , pp. 746-757
    • LaConte, S.M.1    Ngan, S.-C.2    Hu, X.3
  • 19
    • 0032988822 scopus 로고    scopus 로고
    • Analysis of dynamic brain imaging data
    • P. P. Mitra and B. Pesaran, "Analysis of dynamic brain imaging data," Biophys. J., vol. 76, pp. 691-708, 1999.
    • (1999) Biophys. J. , vol.76 , pp. 691-708
    • Mitra, P.P.1    Pesaran, B.2
  • 20
    • 0036430903 scopus 로고    scopus 로고
    • Noise reduction in BOLD-based fMRI using component analysis
    • C. G. Thomas, R. A. Harshman, and R. S. Menon, "Noise reduction in BOLD-based fMRI using component analysis," NeuroImage, vol. 17, pp. 1521-1537, 2002.
    • (2002) NeuroImage , vol.17 , pp. 1521-1537
    • Thomas, C.G.1    Harshman, R.A.2    Menon, R.S.3
  • 21
    • 0028285121 scopus 로고
    • Reduction of signal fluctuation in functional MRI using navigator echoes
    • X. Hu and S.-G. Kim, "Reduction of signal fluctuation in functional MRI using navigator echoes," Magn. Reson. Med., vol. 31, pp. 495-503, 1994.
    • (1994) Magn. Reson. Med. , vol.31 , pp. 495-503
    • Hu, X.1    Kim, S.-G.2
  • 22
    • 0029118783 scopus 로고
    • Retrospective estimation and correction of physiological fluctuation in functional MRI
    • X. Hu, T. H. Le, T. Parrish, and P. Erhard, "Retrospective estimation and correction of physiological fluctuation in functional MRI," Magn. Resonan. Med., vol. 34, pp. 201-212, 1995.
    • (1995) Magn. Resonan. Med. , vol.34 , pp. 201-212
    • Hu, X.1    Le, T.H.2    Parrish, T.3    Erhard, P.4
  • 23
    • 0008913870 scopus 로고    scopus 로고
    • Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data
    • T. H. Le and X. Hu, "Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data," Magn. Resonan. Med., vol. 35, pp. 290-298, 1996.
    • (1996) Magn. Resonan. Med. , vol.35 , pp. 290-298
    • Le, T.H.1    Hu, X.2
  • 24
    • 0034904235 scopus 로고    scopus 로고
    • IMPACT: Image-based physiological artifacts estimation and correction technique for functional MRI
    • K.-H. Chuang and J.-H. Chen, "IMPACT: Image-based physiological artifacts estimation and correction technique for functional MRI," Magn. Reson. Med., vol. 46, pp. 344-353, 2001.
    • (2001) Magn. Reson. Med. , vol.46 , pp. 344-353
    • Chuang, K.-H.1    Chen, J.-H.2
  • 25
    • 0035088894 scopus 로고    scopus 로고
    • Estimation of respirationinduced noise fluctuations from undersampled multislice fMRI data
    • L. R. Frank, R. B. Buxton, and E. C. Wong, "Estimation of respirationinduced noise fluctuations from undersampled multislice fMRI data," Magn. Reson. Med., vol. 45, pp. 635-644, 2001.
    • (2001) Magn. Reson. Med. , vol.45 , pp. 635-644
    • Frank, L.R.1    Buxton, R.B.2    Wong, E.C.3
  • 27
    • 20744433195 scopus 로고    scopus 로고
    • Use of spatial correlations for removal of structured noise in fMRI
    • Toronto, ON, Canada
    • G. H. Turner and D. B. Twieg, "Use of spatial correlations for removal of structured noise in fMRI," presented at the ISMRM 11th Scientific Meeting, Toronto, ON, Canada, 2003.
    • (2003) ISMRM 11th Scientific Meeting
    • Turner, G.H.1    Twieg, D.B.2
  • 28
    • 20744444692 scopus 로고    scopus 로고
    • FMRI noise variability across subjects and trials: Insights for signal processing strategies
    • Sydney, NSW, Australia
    • P. Purdon, V. Solo, M. Rotte, R. Buckner, E. Brown, and R. Weisskoff, "fMRI noise variability across subjects and trials: Insights for signal processing strategies," presented at the ISMRM 6th Scientific Meeting, Sydney, NSW, Australia, 1998.
    • (1998) ISMRM 6th Scientific Meeting
    • Purdon, P.1    Solo, V.2    Rotte, M.3    Buckner, R.4    Brown, E.5    Weisskoff, R.6
  • 30
    • 0033934775 scopus 로고    scopus 로고
    • Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR
    • G. H. Glover, T.-Q. Li, and D. Ress, "Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR," Magn. Reson. Med., vol. 44, pp. 162-167, 2000.
    • (2000) Magn. Reson. Med. , vol.44 , pp. 162-167
    • Glover, G.H.1    Li, T.-Q.2    Ress, D.3
  • 32
    • 0032991979 scopus 로고    scopus 로고
    • Blind source separation of multiple signal sources of fMRI data sets using independent component analysis
    • B. Biswal and J. Ulmer, "Blind source separation of multiple signal sources of fMRI data sets using independent component analysis," J. Comput. Assist. Tomogr., vol. 23, pp. 265-271, 1999.
    • (1999) J. Comput. Assist. Tomogr. , vol.23 , pp. 265-271
    • Biswal, B.1    Ulmer, J.2
  • 33
    • 0036331142 scopus 로고    scopus 로고
    • ICA of fMRI group study data
    • M. Svensen, F. Kruggel, and H. Benali, "ICA of fMRI group study data," NeuroImage, vol. 16, pp. 551-563, 2002.
    • (2002) NeuroImage , vol.16 , pp. 551-563
    • Svensen, M.1    Kruggel, F.2    Benali, H.3
  • 35
    • 0000466122 scopus 로고    scopus 로고
    • Survey on independent component analysis
    • A. Hyvarinen, "Survey on independent component analysis," Neural Computing Surveys, vol. 2, pp. 94-128, 1999.
    • (1999) Neural Computing Surveys , vol.2 , pp. 94-128
    • Hyvarinen, A.1
  • 36
    • 0032629347 scopus 로고    scopus 로고
    • Fast and robust fixed-point algorithms for independent component analysis
    • May
    • A. Hyvarinen, "Fast and robust fixed-point algorithms for independent component analysis," IEEE Trans. Neural Networks, vol. 10, no. 3, pp. 626-634, May 1999.
    • (1999) IEEE Trans. Neural Networks , vol.10 , Issue.3 , pp. 626-634
    • Hyvarinen, A.1
  • 39
    • 20744437918 scopus 로고    scopus 로고
    • Is VBR video non-stationary or self-similar? Implications for ATM traffic characterization
    • Budapest, Hungary
    • S. Bates and S. McLaughlin, "Is VBR video non-stationary or self-similar? Implications for ATM traffic characterization," presented at the 10th Annu. Eur. Simulation MulitConference, Budapest, Hungary, 1996.
    • (1996) 10th Annu. Eur. Simulation MulitConference
    • Bates, S.1    McLaughlin, S.2
  • 40
    • 0036294222 scopus 로고    scopus 로고
    • Independent component analysis of fMRI data in the complex domain
    • V. Calhoun, T. Adali, G. Pearlson, P. van Zijl, and J. Pekar, "Independent component analysis of fMRI data in the complex domain," Magn. Reson. Med., vol. 48, pp. 180-192, 2002.
    • (2002) Magn. Reson. Med. , vol.48 , pp. 180-192
    • Calhoun, V.1    Adali, T.2    Pearlson, G.3    Van Zijl, P.4    Pekar, J.5
  • 41
    • 0035172708 scopus 로고    scopus 로고
    • FMRI activation in a visual-perception task: Network of areas detected using the general linear model and independent component analysis
    • V. Calhoun, T. Adali, V. McGinty, J. Pekar, T. Watson, and G. Pearlson, "fMRI activation in a visual-perception task: Network of areas detected using the general linear model and independent component analysis," NeuroImage, vol. 14, pp. 1080-1088, 2001.
    • (2001) NeuroImage , vol.14 , pp. 1080-1088
    • Calhoun, V.1    Adali, T.2    McGinty, V.3    Pekar, J.4    Watson, T.5    Pearlson, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.