메뉴 건너뛰기




Volumn 46, Issue 5, 2005, Pages 840-849

Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation

Author keywords

3 dimensional dosimetry; 131I; Monte Carlo dosimetry; Radioimmunotherapy; SPECT

Indexed keywords

IODINE 131; RADIOISOTOPE; DIAGNOSTIC AGENT; RADIOACTIVE IODINE;

EID: 20644463730     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (134)

References (32)
  • 1
    • 0029163551 scopus 로고
    • Phase II trial of I-131 B1 (anti CD20) antibody therapy with autologous stem cell transplantation for relapsed B-cell lymphomas
    • Press O, Early J, Appelbaum F, et al. Phase II trial of I-131 B1 (anti CD20) antibody therapy with autologous stem cell transplantation for relapsed B-cell lymphomas. Lancet 1995;346:336-340.
    • (1995) Lancet , vol.346 , pp. 336-340
    • Press, O.1    Early, J.2    Appelbaum, F.3
  • 2
    • 8944248819 scopus 로고    scopus 로고
    • Iodine-131 anti B1 radioimmunotherapy for B-cel lymphoma
    • Kaminshi MS, Zasadny KR, Francis IR, et al. Iodine-131 anti B1 radioimmunotherapy for B-cel lymphoma. J Clin Oncol. 1996;14:1974-1981.
    • (1996) J Clin Oncol , vol.14 , pp. 1974-1981
    • Kaminshi, M.S.1    Zasadny, K.R.2    Francis, I.R.3
  • 3
    • 0031471674 scopus 로고    scopus 로고
    • Increased survival associated with radiolabeled lym-1 therapy for non-Hodgkin's lymphoma and chronic lymphocytic leukemia
    • DeNardo GL, Lambom KR, Goldstein DS, Kroger LA, DeNardo SJ. Increased survival associated with radiolabeled lym-1 therapy for non-Hodgkin's lymphoma and chronic lymphocytic leukemia. Cancer. 1997;80:2706-2711.
    • (1997) Cancer , vol.80 , pp. 2706-2711
    • DeNardo, G.L.1    Lambom, K.R.2    Goldstein, D.S.3    Kroger, L.A.4    DeNardo, S.J.5
  • 4
    • 12944275472 scopus 로고    scopus 로고
    • I-131 tositumomab therapy as initial treatment for follicular lymphoma
    • Kaminski MS, Tuck M, Estes J, et al. I-131 tositumomab therapy as initial treatment for follicular lymphoma. N Engl J Med. 2005;352:441-449.
    • (2005) N Engl J Med , vol.352 , pp. 441-449
    • Kaminski, M.S.1    Tuck, M.2    Estes, J.3
  • 5
    • 0037089597 scopus 로고    scopus 로고
    • Pilot study of iodine-131-metaiodobenzylguanidine in combination with myeloablative chemotherapy and autologous stem cell support for the treatment of neuroblastoma
    • Yanik GA, Levine JE, Matthay KK, et al. Pilot study of iodine-131-metaiodobenzylguanidine in combination with myeloablative chemotherapy and autologous stem cell support for the treatment of neuroblastoma. J Clin Oncol. 2002; 20:2142-2149.
    • (2002) J Clin Oncol , vol.20 , pp. 2142-2149
    • Yanik, G.A.1    Levine, J.E.2    Matthay, K.K.3
  • 6
    • 0026357908 scopus 로고
    • Efficacy and safely of I-131 metaiodobenzylguanidine therapy for patients with refractory neuroblastoma
    • Matthay KK, Huberty JP, Harmer RS, et al. Efficacy and safely of I-131 metaiodobenzylguanidine therapy for patients with refractory neuroblastoma. J Nucl Biol Med. 1991;35:244-247.
    • (1991) J Nucl Biol Med , vol.35 , pp. 244-247
    • Matthay, K.K.1    Huberty, J.P.2    Harmer, R.S.3
  • 7
    • 0032587116 scopus 로고    scopus 로고
    • Factors affecting 131-I-Lym-1 pharmacokinetics and radiation dosimetry in patients with non Hodgkin's lymphoma and chronic lymphocytic leukemia
    • DeNardo GL, DeNardo SJ, Shen S, et al. Factors affecting 131-I-Lym-1 pharmacokinetics and radiation dosimetry in patients with non Hodgkin's lymphoma and chronic lymphocytic leukemia. J Nucl Med. 1999;40:1317-1326.
    • (1999) J Nucl Med , vol.40 , pp. 1317-1326
    • DeNardo, G.L.1    DeNardo, S.J.2    Shen, S.3
  • 9
    • 0037364939 scopus 로고    scopus 로고
    • 131I-tositumomab therapy of previously untreated lymphoma patients
    • 131I-tositumomab therapy of previously untreated lymphoma patients. J Nucl Med. 2003;44:457-464.
    • (2003) J Nucl Med , vol.44 , pp. 457-464
    • Koral, K.F.1    Dewaraja, Y.2    Li, J.3
  • 10
    • 0031759837 scopus 로고    scopus 로고
    • Maximum tolerated dose, toxicity and efficacy of I-131-Lym-1 antibody for fractionated radioimmunotherapy of non-Hodgkin's lymphoma
    • DeNardo GL, DeNardo SJ, Goldstein DS, et al. Maximum tolerated dose, toxicity and efficacy of I-131-Lym-1 antibody for fractionated radioimmunotherapy of non-Hodgkin's lymphoma. J Clin Oncol. 1998;16:3246-3256.
    • (1998) J Clin Oncol , vol.16 , pp. 3246-3256
    • DeNardo, G.L.1    DeNardo, S.J.2    Goldstein, D.S.3
  • 11
    • 0034809052 scopus 로고    scopus 로고
    • Pretargeted radioimmunotherapy for the treatment of non-Hodgkin's lymphoma
    • Weiden PL, Breitz HB. Pretargeted radioimmunotherapy for the treatment of non-Hodgkin's lymphoma. Clin Rev Oncol Hematol. 2001;40:37-51.
    • (2001) Clin Rev Oncol Hematol , vol.40 , pp. 37-51
    • Weiden, P.L.1    Breitz, H.B.2
  • 12
    • 0003208862 scopus 로고    scopus 로고
    • Results of a randomized trial of Bexxar (tositumomab and I 131 tositumomab) vs unlabeled tositumomab in patients with relapsed or refractory low grade or transformed non-Hodgkin's lymphoma
    • Davis TA, Kaminski MS, Leonard JP, et al. Results of a randomized trial of Bexxar (tositumomab and I 131 tositumomab) vs unlabeled tositumomab in patients with relapsed or refractory low grade or transformed non-Hodgkin's lymphoma [abstract]. Blood 2001;98:843.
    • (2001) Blood , vol.98 , pp. 843
    • Davis, T.A.1    Kaminski, M.S.2    Leonard, J.P.3
  • 13
    • 0033623357 scopus 로고    scopus 로고
    • Accuracy of I-131 tumor quantification in radioimmunotherapy using SPECT imaging with an ultra high-energy collimator: Monte Carlo study
    • Dewaraja YK, Ljungberg M, Koral KF. Accuracy of I-131 tumor quantification in radioimmunotherapy using SPECT imaging with an ultra high-energy collimator: Monte Carlo study, J Nucl Med. 2000;41:1760-1767.
    • (2000) J Nucl Med , vol.41 , pp. 1760-1767
    • Dewaraja, Y.K.1    Ljungberg, M.2    Koral, K.F.3
  • 14
    • 2642629710 scopus 로고    scopus 로고
    • Quantitative imaging of I-131 distributions in brain tumors with pinhole SPECT: A phantom study
    • Smith MF, Gilland DR, Coleman RE, Jaszczak RJ. Quantitative imaging of I-131 distributions in brain tumors with pinhole SPECT: a phantom study. J Nucl Med. 1998;39:856-864.
    • (1998) J Nucl Med , vol.39 , pp. 856-864
    • Smith, M.F.1    Gilland, D.R.2    Coleman, R.E.3    Jaszczak, R.J.4
  • 15
    • 0035355182 scopus 로고    scopus 로고
    • High resolution absolute SPECT quantitation for I-131 distributions used in the treatment of lymphoma: A phantom study
    • Gonzalez Trotter DE, Jaszczak RJ, Bowsher JE, Akabani G, Greer KL. High resolution absolute SPECT quantitation for I-131 distributions used in the treatment of lymphoma: a phantom study. IEEE Trans Nucl Sci. 2001;48:707-714.
    • (2001) IEEE Trans Nucl Sci , vol.48 , pp. 707-714
    • Gonzalez Trotter, D.E.1    Jaszczak, R.J.2    Bowsher, J.E.3    Akabani, G.4    Greer, K.L.5
  • 16
    • 0036327084 scopus 로고    scopus 로고
    • A three dimensional absorbed dose calculation method based on quantitative SPECT for radionuclide therapy: Evaluation for I-131 using Monte Carlo simulation
    • Ljungberg M, Sjogreen K, Liu X, Frey E, Dewaraja YK, Strand S. A three dimensional absorbed dose calculation method based on quantitative SPECT for radionuclide therapy: evaluation for I-131 using Monte Carlo simulation. J Nucl Med. 2002;43:1101-1109.
    • (2002) J Nucl Med , vol.43 , pp. 1101-1109
    • Ljungberg, M.1    Sjogreen, K.2    Liu, X.3    Frey, E.4    Dewaraja, Y.K.5    Strand, S.6
  • 17
    • 3342960035 scopus 로고    scopus 로고
    • Determining total I-131 activity within a VOI using SPECT, a UHE collimator, OSEM and a constant conversion factor
    • Koral KF, Yendiki A, Lin Q, Dewaraja YK, Fessler JA. Determining total I-131 activity within a VOI using SPECT, a UHE collimator, OSEM and a constant conversion factor. IEEE Trans Nucl Sci. 2004;51:611-618.
    • (2004) IEEE Trans Nucl Sci , vol.51 , pp. 611-618
    • Koral, K.F.1    Yendiki, A.2    Lin, Q.3    Dewaraja, Y.K.4    Fessler, J.A.5
  • 19
    • 0027133504 scopus 로고
    • Photon contribution to tumor dose from considerations of I-131 radiolabeled antibody uptake in liver, spleen and whole body
    • Johnson TK, Colby SB. Photon contribution to tumor dose from considerations of I-131 radiolabeled antibody uptake in liver, spleen and whole body. Med Phys. 1993;6:1667-1674.
    • (1993) Med Phys , vol.6 , pp. 1667-1674
    • Johnson, T.K.1    Colby, S.B.2
  • 20
    • 0032914624 scopus 로고    scopus 로고
    • Internal dosimetry in the use of radiopharmaceuticals in therapy science at a crossroads?
    • Stabin MG. Internal dosimetry in the use of radiopharmaceuticals in therapy science at a crossroads? Cancer Biother Radiopharm. 1999:14:81-89.
    • (1999) Cancer Biother Radiopharm , vol.14 , pp. 81-89
    • Stabin, M.G.1
  • 21
    • 0033973808 scopus 로고    scopus 로고
    • Internal radionuclide radiation dosimetry: A review of basic concepts and recent developments
    • Zanzonico PB. Internal radionuclide radiation dosimetry: a review of basic concepts and recent developments. J Nucl Med. 2000;41:297-308.
    • (2000) J Nucl Med , vol.41 , pp. 297-308
    • Zanzonico, P.B.1
  • 22
    • 0030796876 scopus 로고    scopus 로고
    • Implementation of Monte Carlo dosimetry method for patient-specific internal emitter therapy
    • Furhang EE, Chui CS, Kolbert KS, et al. Implementation of Monte Carlo dosimetry method for patient-specific internal emitter therapy. Med Phys. 1997; 24:1163-1172.
    • (1997) Med Phys , vol.24 , pp. 1163-1172
    • Furhang, E.E.1    Chui, C.S.2    Kolbert, K.S.3
  • 23
    • 0035047570 scopus 로고    scopus 로고
    • Monte Carlo MCNP-4B based absorbed dose distribution estimates for patient-specific dosimetry
    • Yoriyaz H, Stabin MG, dos Santos A. Monte Carlo MCNP-4B based absorbed dose distribution estimates for patient-specific dosimetry. J Nucl Med. 2001;42: 662-669.
    • (2001) J Nucl Med , vol.42 , pp. 662-669
    • Yoriyaz, H.1    Stabin, M.G.2    Dos Santos, A.3
  • 26
    • 0033867657 scopus 로고    scopus 로고
    • DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations
    • Sempau J, Wilderman S, Bielajew AF. DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations. Phys Med Biol. 2000;45:2263-2291.
    • (2000) Phys Med Biol , vol.45 , pp. 2263-2291
    • Sempau, J.1    Wilderman, S.2    Bielajew, A.F.3
  • 27
    • 0037035849 scopus 로고    scopus 로고
    • Experimental validation of the DPM Monte Carlo code using minimally scattered election beams in heterogeneous media
    • Chetty IJ, Moran JM, Nurushev DL, et al. Experimental validation of the DPM Monte Carlo code using minimally scattered election beams in heterogeneous media. Phys Med Biol. 2002;47:1837-1851.
    • (2002) Phys Med Biol , vol.47 , pp. 1837-1851
    • Chetty, I.J.1    Moran, J.M.2    Nurushev, D.L.3
  • 29
    • 0030002992 scopus 로고    scopus 로고
    • MIRDOSE: Personal computer software for internal dose assessment in nuclear medicine
    • Stabin M. MIRDOSE: personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 1996;7:538-546.
    • (1996) J Nucl Med , vol.7 , pp. 538-546
    • Stabin, M.1
  • 30
    • 0033796610 scopus 로고    scopus 로고
    • 131I-anti-B antibody therapy of previously untreated patients with lymphoma
    • 131I-anti-B antibody therapy of previously untreated patients with lymphoma. J Nucl Med. 2000;41:1579-1586.
    • (2000) J Nucl Med , vol.41 , pp. 1579-1586
    • Koral, K.F.1    Dewaraja, Y.2    Li, J.3
  • 31
    • 4544236386 scopus 로고    scopus 로고
    • 124I PET and 3-dimensional internal dosimetry (3D-ID) software
    • 124I PET and 3-dimensional internal dosimetry (3D-ID) software. J Nucl Med. 2004;45:1366-1372.
    • (2004) J Nucl Med , vol.45 , pp. 1366-1372
    • Sgouros, G.1    Kolbert, K.S.2    Sheikh, A.3
  • 32
    • 33646719775 scopus 로고    scopus 로고
    • Comparison of planar, quantitative SPECT, and combined planar-quantitative SPECT organ residence time estimation methods for targeted radionuclide therapy dosimetry
    • Frey EC, He B, Sgouros G, et al. Comparison of planar, quantitative SPECT, and combined planar-quantitative SPECT organ residence time estimation methods for targeted radionuclide therapy dosimetry [abstract]. J Nucl Med. 2004; 45(suppl):46P.
    • (2004) J Nucl Med , vol.45 , Issue.SUPPL.
    • Frey, E.C.1    He, B.2    Sgouros, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.