메뉴 건너뛰기




Volumn 24, Issue 1, 2005, Pages 1-13

Technique-sensitivity of contemporary adhesives

Author keywords

Adhesive interface; Chemical interaction; Self etch

Indexed keywords

2 HYDROXYETHYL METHACRYLATE; ADHESIVE AGENT; DENTIN BONDING AGENT; GLASS IONOMER; METHACRYLIC ACID DERIVATIVE; RESIN CEMENT; WETTING AGENT;

EID: 20644443258     PISSN: 02874547     EISSN: None     Source Type: Journal    
DOI: 10.4012/dmj.24.1     Document Type: Review
Times cited : (291)

References (83)
  • 2
    • 7244245439 scopus 로고    scopus 로고
    • Micromorphological evaluation of posterior composite restorations - A 10-year report
    • Gaengler P, Hoyer I, Montag R, Gaebler P. Micromorphological evaluation of posterior composite restorations - a 10-year report. J Oral Rehabil 2004; 31: 991-1000.
    • (2004) J Oral Rehabil , vol.31 , pp. 991-1000
    • Gaengler, P.1    Hoyer, I.2    Montag, R.3    Gaebler, P.4
  • 3
    • 2942552386 scopus 로고    scopus 로고
    • Bronkhorst EM. Five-year clinical performance of posterior resin composite restorations placed by dental students
    • Opdam NJ, Loomans BA, Roeters FJ, Bronkhorst EM. Five-year clinical performance of posterior resin composite restorations placed by dental students. J Dent 2004; 32: 379-383.
    • (2004) J Dent , vol.32 , pp. 379-383
    • Opdam, N.J.1    Loomans, B.A.2    Roeters, F.J.3
  • 8
    • 0020137778 scopus 로고
    • The promotion of adhesion by the infiltration of monomers into tooth substrates
    • Nakabayashi N, Kojima K, Masuhara E. The promotion of adhesion by the infiltration of monomers into tooth substrates. J Biomed Mater Res 1982; 16: 265-273.
    • (1982) J Biomed Mater Res , vol.16 , pp. 265-273
    • Nakabayashi, N.1    Kojima, K.2    Masuhara, E.3
  • 9
    • 0042522352 scopus 로고    scopus 로고
    • Water treeing-a potential mechanism for degradation of dentin adhesives
    • Tay FR, Pashley DH. Water treeing-a potential mechanism for degradation of dentin adhesives. Am J Dent 2003; 16: 6-12.
    • (2003) Am J Dent , vol.16 , pp. 6-12
    • Tay, F.R.1    Pashley, D.H.2
  • 10
    • 0026903849 scopus 로고
    • Morphological aspects of the resin-dentin interdiffusion zone with different dentin adhesive systems
    • Van Meerbeek B, Inokoshi S, Braem M, Lambrechts P, Vanherle G. Morphological aspects of the resin-dentin interdiffusion zone with different dentin adhesive systems. J Dent Res 1992; 71: 1530-1540.
    • (1992) J Dent Res , vol.71 , pp. 1530-1540
    • Van Meerbeek, B.1    Inokoshi, S.2    Braem, M.3    Lambrechts, P.4    Vanherle, G.5
  • 11
    • 0030307315 scopus 로고    scopus 로고
    • Correlative transmission electron microscopy examination of nondemineralized and demineralized resin-dentin interfaces formed by two dentin adhesive systems
    • Van Meerbeek B, Conn LJ Jr, Duke ES, Eick JD, Robinson SJ, Guerrero D. Correlative transmission electron microscopy examination of nondemineralized and demineralized resin-dentin interfaces formed by two dentin adhesive systems. J Dent Res 1996; 75: 879-888.
    • (1996) J Dent Res , vol.75 , pp. 879-888
    • Van Meerbeek, B.1    Conn Jr., L.J.2    Duke, E.S.3    Eick, J.D.4    Robinson, S.J.5    Guerrero, D.6
  • 13
    • 0031242394 scopus 로고    scopus 로고
    • Bonding mechanism of three "one-bottle" systems to conditioned and unconditioned enamel and dentin
    • Ferrari M, Goracci G, Garcia-Godoy F. Bonding mechanism of three "one-bottle" systems to conditioned and unconditioned enamel and dentin. Am J Dent 1997; 10: 224-230.
    • (1997) Am J Dent , vol.10 , pp. 224-230
    • Ferrari, M.1    Goracci, G.2    Garcia-Godoy, F.3
  • 14
    • 0028441411 scopus 로고
    • Chemically conditioned dentin: A comparison of conventional and environmental scanning electron microscopy findings
    • Gwinnett AJ. Chemically conditioned dentin: a comparison of conventional and environmental scanning electron microscopy findings. Dent Mater 1994; 10: 150-155.
    • (1994) Dent Mater , vol.10 , pp. 150-155
    • Gwinnett, A.J.1
  • 15
    • 0030307296 scopus 로고    scopus 로고
    • The effects of acetone, ethanol, HEMA, and air on the stiffness of human decalcified dentin matrix
    • Maciel KT, Carvalho RM, Ringle RD, Preston CD, Russell CM, Pashley DH. The effects of acetone, ethanol, HEMA, and air on the stiffness of human decalcified dentin matrix. J Dent Res 1996; 75: 1851-1858.
    • (1996) J Dent Res , vol.75 , pp. 1851-1858
    • Maciel, K.T.1    Carvalho, R.M.2    Ringle, R.D.3    Preston, C.D.4    Russell, C.M.5    Pashley, D.H.6
  • 16
    • 0035409333 scopus 로고    scopus 로고
    • A tapping mode AFM study of collapse and denaturation in dentinal collagen
    • El Feninat F, Ellis TH, Sacher E, Stangel I. A tapping mode AFM study of collapse and denaturation in dentinal collagen. Dent Mater 2001; 17: 284-288.
    • (2001) Dent Mater , vol.17 , pp. 284-288
    • El Feninat, F.1    Ellis, T.H.2    Sacher, E.3    Stangel, I.4
  • 17
    • 0026830420 scopus 로고
    • Effect of HEMA on bonding to dentin
    • Nakabayashi N, Takarada K. Effect of HEMA on bonding to dentin. Dent Mater 1992; 8: 125-130.
    • (1992) Dent Mater , vol.8 , pp. 125-130
    • Nakabayashi, N.1    Takarada, K.2
  • 19
    • 0027546912 scopus 로고
    • Comparative SEM and TEM examination of the ultrastructure of the resin-dentin interdiffusion zone
    • Van Meerbeek B, Dhem A, Goret-Nicaise M, Braem M, Lambrechts P, Vanherle G. Comparative SEM and TEM examination of the ultrastructure of the resin-dentin interdiffusion zone. J Dent Res 1993; 72: 495-501.
    • (1993) J Dent Res , vol.72 , pp. 495-501
    • Van Meerbeek, B.1    Dhem, A.2    Goret-Nicaise, M.3    Braem, M.4    Lambrechts, P.5    Vanherle, G.6
  • 20
  • 22
    • 4143149600 scopus 로고    scopus 로고
    • A randomized, controlled trial evaluating the three-year clinical effectiveness of two etch & rinse adhesives in cervical lesions
    • Van Meerbeek B, Kanumilli PV, De Munck J, Van Landuyt K, Lambrechts P, Peumans M. A randomized, controlled trial evaluating the three-year clinical effectiveness of two etch & rinse adhesives in cervical lesions. Oper Dent 2004; 29: 376-385.
    • (2004) Oper Dent , vol.29 , pp. 376-385
    • Van Meerbeek, B.1    Kanumilli, P.V.2    De Munck, J.3    Van Landuyt, K.4    Lambrechts, P.5    Peumans, M.6
  • 23
    • 0034230545 scopus 로고    scopus 로고
    • Clinical evaluation of three adhesive systems in class V non-carious lesions
    • van Dijken JW. Clinical evaluation of three adhesive systems in class V non-carious lesions. Dent Mater 2000; 16: 285-291.
    • (2000) Dent Mater , vol.16 , pp. 285-291
    • Van Dijken, J.W.1
  • 25
    • 0033233519 scopus 로고    scopus 로고
    • Practitioner variability effects on dentin bonding with an acetone-based one bottle adhesive
    • Finger WJ, Balkenhol M. Practitioner variability effects on dentin bonding with an acetone-based one bottle adhesive. J Adhes Dent 1999; 1: 311-314.
    • (1999) J Adhes Dent , vol.1 , pp. 311-314
    • Finger, W.J.1    Balkenhol, M.2
  • 27
    • 0028398530 scopus 로고
    • Microporous dentin zone beneath resin-impregnated layer
    • Sano H, Shono T, Takatsu T, Hosoda H. Microporous dentin zone beneath resin-impregnated layer. Oper Dent 1994; 19: 59-64.
    • (1994) Oper Dent , vol.19 , pp. 59-64
    • Sano, H.1    Shono, T.2    Takatsu, T.3    Hosoda, H.4
  • 28
    • 0034198959 scopus 로고    scopus 로고
    • Calcium leaching from dentin and shear bond strength after etching with phosphoric acid of different concentrations
    • Jacobsen T, Soderholm KJ, Garcea I, Mondragon E. Calcium leaching from dentin and shear bond strength after etching with phosphoric acid of different concentrations. Eur J Oral Sci 2000; 108: 247-254.
    • (2000) Eur J Oral Sci , vol.108 , pp. 247-254
    • Jacobsen, T.1    Soderholm, K.J.2    Garcea, I.3    Mondragon, E.4
  • 29
    • 0034157977 scopus 로고    scopus 로고
    • Rewetting strategies for bonding to dry dentin with an acetone-based adhesive
    • Finger WJ, Balkenhol M. Rewetting strategies for bonding to dry dentin with an acetone-based adhesive. J Adhes Dent 2000; 2: 51-56.
    • (2000) J Adhes Dent , vol.2 , pp. 51-56
    • Finger, W.J.1    Balkenhol, M.2
  • 30
    • 0034231236 scopus 로고    scopus 로고
    • Technique sensitivity of dentin bonding: Effect of application mistakes on bond strength and marginal adaptation
    • Frankenberger R, Kramer N, Petschelt A. Technique sensitivity of dentin bonding: effect of application mistakes on bond strength and marginal adaptation. Oper Dent 2000; 25: 324-330.
    • (2000) Oper Dent , vol.25 , pp. 324-330
    • Frankenberger, R.1    Kramer, N.2    Petschelt, A.3
  • 31
    • 0026877761 scopus 로고
    • Moist versus dry dentin: Its effect on shear bond strength
    • Gwinnett AJ. Moist versus dry dentin: its effect on shear bond strength. Am J Dent 1992; 5: 127-129.
    • (1992) Am J Dent , vol.5 , pp. 127-129
    • Gwinnett, A.J.1
  • 32
    • 0026906858 scopus 로고
    • Effect of resin primer solvents and surface wetness on resin composite bond strength to dentin
    • Kanca III J. Effect of resin primer solvents and surface wetness on resin composite bond strength to dentin. Am J Dent 1992; 5: 213-215.
    • (1992) Am J Dent , vol.5 , pp. 213-215
    • Kanca III, J.1
  • 33
    • 0030307212 scopus 로고    scopus 로고
    • Resin permeation into acid-conditioned, moist, and dry dentin: A paradigm using water-free adhesive primers
    • Tay FR, Gwinnett AJ, Pang KM, Wei SH. Resin permeation into acid-conditioned, moist, and dry dentin: a paradigm using water-free adhesive primers. J Dent Res 1996; 75: 1034-1044.
    • (1996) J Dent Res , vol.75 , pp. 1034-1044
    • Tay, F.R.1    Gwinnett, A.J.2    Pang, K.M.3    Wei, S.H.4
  • 34
    • 0030180192 scopus 로고    scopus 로고
    • Micromorphological spectrum from overdrying to overwetting acid-conditioned dentin in water-free acetone-based, single-bottle primer/adhesives
    • Tay FR, Gwinnett JA, Wei SH. Micromorphological spectrum from overdrying to overwetting acid-conditioned dentin in water-free acetone-based, single-bottle primer/adhesives. Dent Mater 1996; 12: 236-244.
    • (1996) Dent Mater , vol.12 , pp. 236-244
    • Tay, F.R.1    Gwinnett, J.A.2    Wei, S.H.3
  • 35
    • 0031082961 scopus 로고    scopus 로고
    • The overwet phenomenon in two-component acetone-based primers containing aryl amine and carboxylic acid monomers
    • Tay FR, Gwinnett JA, Wei SH. The overwet phenomenon in two-component acetone-based primers containing aryl amine and carboxylic acid monomers. Dent Mater 1997; 13: 118-127.
    • (1997) Dent Mater , vol.13 , pp. 118-127
    • Tay, F.R.1    Gwinnett, J.A.2    Wei, S.H.3
  • 36
    • 0030073086 scopus 로고    scopus 로고
    • The overwet phenomenon: An optical, micromorphological study of surface moisture in the acid-conditioned, resin-dentin interface
    • Tay FR, Gwinnett AJ, Wei SH. The overwet phenomenon: an optical, micromorphological study of surface moisture in the acid-conditioned, resin-dentin interface. Am J Dent 1996; 9: 43-48.
    • (1996) Am J Dent , vol.9 , pp. 43-48
    • Tay, F.R.1    Gwinnett, A.J.2    Wei, S.H.3
  • 37
    • 0033129016 scopus 로고    scopus 로고
    • The effect of dentine location and tubule orientation on the bond strengths between resin and dentine
    • Phrukkanon S, Burrow MF, Tyas MJ. The effect of dentine location and tubule orientation on the bond strengths between resin and dentine. J Dent 1999; 27: 265-274.
    • (1999) J Dent , vol.27 , pp. 265-274
    • Phrukkanon, S.1    Burrow, M.F.2    Tyas, M.J.3
  • 39
    • 0034330050 scopus 로고    scopus 로고
    • The effect of hybrid layer thickness on bond strength: Demineralized dentin zone of the hybrid layer
    • Hashimoto M, Ohno H, Endo K, Kaga M, Sano H, Oguchi H. The effect of hybrid layer thickness on bond strength: demineralized dentin zone of the hybrid layer. Dent Mater 2000; 16: 406-411.
    • (2000) Dent Mater , vol.16 , pp. 406-411
    • Hashimoto, M.1    Ohno, H.2    Endo, K.3    Kaga, M.4    Sano, H.5    Oguchi, H.6
  • 40
    • 0034443787 scopus 로고    scopus 로고
    • In vivo degradation of resin-dentin bonds in humans over 1 to 3 years
    • Hashimoto M, Ohno H, Kaga M, Endo K, Sano H, Oguchi H. In vivo degradation of resin-dentin bonds in humans over 1 to 3 years. J Dent Res 2000; 79: 1385-1391.
    • (2000) J Dent Res , vol.79 , pp. 1385-1391
    • Hashimoto, M.1    Ohno, H.2    Kaga, M.3    Endo, K.4    Sano, H.5    Oguchi, H.6
  • 41
  • 42
    • 0642275700 scopus 로고    scopus 로고
    • Have dentin adhesives become too hydrophilic?
    • Tay FR, Pashley DH. Have dentin adhesives become too hydrophilic? J Can Dent Assoc 2003; 69: 726-731.
    • (2003) J Can Dent Assoc , vol.69 , pp. 726-731
    • Tay, F.R.1    Pashley, D.H.2
  • 43
    • 0034208769 scopus 로고    scopus 로고
    • Effect of smear layers on the bonding of a self-etching primer to dentin
    • Tay FR, Carvalho R, Sano H, Pashley DH. Effect of smear layers on the bonding of a self-etching primer to dentin. J Adhes Dent 2000; 2: 99-116.
    • (2000) J Adhes Dent , vol.2 , pp. 99-116
    • Tay, F.R.1    Carvalho, R.2    Sano, H.3    Pashley, D.H.4
  • 44
    • 0034208378 scopus 로고    scopus 로고
    • An ultrastructural study of the influence of acidity of self-etching primers and smear layer thickness on bonding to intact dentin
    • Tay FR, Sano H, Carvalho R, Pashley EL, Pashley DH. An ultrastructural study of the influence of acidity of self-etching primers and smear layer thickness on bonding to intact dentin. J Adhes Dent 2000; 2: 83-98.
    • (2000) J Adhes Dent , vol.2 , pp. 83-98
    • Tay, F.R.1    Sano, H.2    Carvalho, R.3    Pashley, E.L.4    Pashley, D.H.5
  • 46
    • 0035462366 scopus 로고    scopus 로고
    • "No-bottle" vs "multi-bottle" dentin adhesives-a microtensile bond strength and morphological study
    • Frankenberger R, Perdigao J, Rosa BT, Lopes M. "No-bottle" vs "multi-bottle" dentin adhesives-a microtensile bond strength and morphological study. Dent Mater 2001; 17: 373-380.
    • (2001) Dent Mater , vol.17 , pp. 373-380
    • Frankenberger, R.1    Perdigao, J.2    Rosa, B.T.3    Lopes, M.4
  • 47
    • 1542758208 scopus 로고    scopus 로고
    • Bonding of mild self-etching primers/adhesives to dentin with thick smear layers
    • Chan KM, Tay FR, King NM, Imazato S, Pashley DH. Bonding of mild self-etching primers/adhesives to dentin with thick smear layers. Am J Dent 2003; 16: 340-346.
    • (2003) Am J Dent , vol.16 , pp. 340-346
    • Chan, K.M.1    Tay, F.R.2    King, N.M.3    Imazato, S.4    Pashley, D.H.5
  • 48
    • 0028453180 scopus 로고
    • Bonding to ground dentin by a phenyl-P self-etching primer
    • Watanabe I, Nakabayashi N, Pashley DH. Bonding to ground dentin by a phenyl-P self-etching primer. J Dent Res 1994; 73: 1212-1220.
    • (1994) J Dent Res , vol.73 , pp. 1212-1220
    • Watanabe, I.1    Nakabayashi, N.2    Pashley, D.H.3
  • 51
    • 0035405736 scopus 로고    scopus 로고
    • Aggressiveness of contemporary self-etching systems. I: Depth of penetration beyond dentin smear layers
    • Tay FR, Pashley DH. Aggressiveness of contemporary self-etching systems. I: Depth of penetration beyond dentin smear layers. Dent Mater 2001; 17: 296-308.
    • (2001) Dent Mater , vol.17 , pp. 296-308
    • Tay, F.R.1    Pashley, D.H.2
  • 52
    • 0038655298 scopus 로고    scopus 로고
    • Effect of smear layer thickness on bond strength mediated by three all-in-one self-etching priming adhesives
    • Tani C, Finger WJ. Effect of smear layer thickness on bond strength mediated by three all-in-one self-etching priming adhesives. J Adhes Dent 2002; 4: 283-289.
    • (2002) J Adhes Dent , vol.4 , pp. 283-289
    • Tani, C.1    Finger, W.J.2
  • 55
    • 0037640986 scopus 로고    scopus 로고
    • How can nanoleakage occur in self-etching adhesive systems that demineralize and infiltrate simultaneously?
    • Tay FR, King NM, Chan KM, Pashley DH. How can nanoleakage occur in self-etching adhesive systems that demineralize and infiltrate simultaneously? J Adhes Dent 2002; 4: 255-269.
    • (2002) J Adhes Dent , vol.4 , pp. 255-269
    • Tay, F.R.1    King, N.M.2    Chan, K.M.3    Pashley, D.H.4
  • 56
    • 0029259111 scopus 로고
    • Some effects of water on dentin bonding
    • Jacobsen T, Soderholm KJ. Some effects of water on dentin bonding. Dent Mater 1995; 11: 132-136.
    • (1995) Dent Mater , vol.11 , pp. 132-136
    • Jacobsen, T.1    Soderholm, K.J.2
  • 57
    • 0141682576 scopus 로고    scopus 로고
    • Clinical evaluation of a self-etching and a one-bottle adhesive system at two years
    • Turkun SL. Clinical evaluation of a self-etching and a one-bottle adhesive system at two years. J Dent 2003; 31: 527-534.
    • (2003) J Dent , vol.31 , pp. 527-534
    • Turkun, S.L.1
  • 58
    • 22144489396 scopus 로고    scopus 로고
    • Two-year clinical effectiveness of a self-etch adhesive in cervical lesions
    • in press
    • Peumans M, Van Meerbeek B, De Munck J, Lambrechts P. Two-year clinical effectiveness of a self-etch adhesive in cervical lesions. Oper Dent 2005 (in press).
    • (2005) Oper Dent
    • Peumans, M.1    Van Meerbeek, B.2    De Munck, J.3    Lambrechts, P.4
  • 60
    • 0346910233 scopus 로고    scopus 로고
    • Effects of the acetone content of single solution dentin bonding agents on the adhesive layer thickness and the microtensile bond strength
    • Cho BH, Dickens SH. Effects of the acetone content of single solution dentin bonding agents on the adhesive layer thickness and the microtensile bond strength. Dent Mater 2004; 20: 107-115.
    • (2004) Dent Mater , vol.20 , pp. 107-115
    • Cho, B.H.1    Dickens, S.H.2
  • 61
    • 0034139768 scopus 로고    scopus 로고
    • Recent developments in dentin bonding
    • Haller B. Recent developments in dentin bonding. Am J Dent 2000; 13: 44-50.
    • (2000) Am J Dent , vol.13 , pp. 44-50
    • Haller, B.1
  • 62
    • 0034208767 scopus 로고    scopus 로고
    • Influence of additional acid etch treatment on resin cement dentin infiltration
    • Walker MP, Wang Y, Swafford J, Evans A, Spencer P. Influence of additional acid etch treatment on resin cement dentin infiltration. J Prosthod 2000; 9: 77-81.
    • (2000) J Prosthod , vol.9 , pp. 77-81
    • Walker, M.P.1    Wang, Y.2    Swafford, J.3    Evans, A.4    Spencer, P.5
  • 64
    • 4444321239 scopus 로고    scopus 로고
    • A challenge to the conventional wisdom that simultaneous etching and resin infiltration always occurs in self-etch adhesives
    • Carvalho RM, Chersoni S, Frankenberger R, Pashley DH, Prati C, Tay FR. A challenge to the conventional wisdom that simultaneous etching and resin infiltration always occurs in self-etch adhesives. Biomaterials 2005; 26: 1035-1042.
    • (2005) Biomaterials , vol.26 , pp. 1035-1042
    • Carvalho, R.M.1    Chersoni, S.2    Frankenberger, R.3    Pashley, D.H.4    Prati, C.5    Tay, F.R.6
  • 65
    • 0034252623 scopus 로고    scopus 로고
    • Self-contamination of deep dentin by dentin fluid
    • Itthagarun A, Tay FR. Self-contamination of deep dentin by dentin fluid. Am J Dent 2000; 13: 195-200.
    • (2000) Am J Dent , vol.13 , pp. 195-200
    • Itthagarun, A.1    Tay, F.R.2
  • 66
    • 0348231865 scopus 로고    scopus 로고
    • Total-etch versus self-etch adhesive: Effect on postoperative sensitivity
    • Perdigao J, Geraldeli S, Hodges JS. Total-etch versus self-etch adhesive: effect on postoperative sensitivity. J Am Dent Assoc 2003; 134: 1621-1629.
    • (2003) J Am Dent Assoc , vol.134 , pp. 1621-1629
    • Perdigao, J.1    Geraldeli, S.2    Hodges, J.S.3
  • 67
    • 0033289370 scopus 로고    scopus 로고
    • Bonding efficiency of single-bottle enamel/dentin adhesives
    • Fritz UB, Finger WJ. Bonding efficiency of single-bottle enamel/dentin adhesives. Am J Dent 1999; 12: 277-282.
    • (1999) Am J Dent , vol.12 , pp. 277-282
    • Fritz, U.B.1    Finger, W.J.2
  • 68
    • 0035233991 scopus 로고    scopus 로고
    • Bond strength of composite to dentin using conventional, one-step, and self-etching adhesive systems
    • Bouillaguet S, Gysi P, Wataha JC, Ciucchi B, Cattani M, Godin C, Meyer JM. Bond strength of composite to dentin using conventional, one-step, and self-etching adhesive systems. J Dent 2001; 29: 55-61.
    • (2001) J Dent , vol.29 , pp. 55-61
    • Bouillaguet, S.1    Gysi, P.2    Wataha, J.C.3    Ciucchi, B.4    Cattani, M.5    Godin, C.6    Meyer, J.M.7
  • 70
    • 0035983862 scopus 로고    scopus 로고
    • Two modes of nanoleakage expression in single-step adhesives
    • Tay FR, Pashley DH, Yoshiyama M. Two modes of nanoleakage expression in single-step adhesives. J Dent Res 2002; 81: 472-476.
    • (2002) J Dent Res , vol.81 , pp. 472-476
    • Tay, F.R.1    Pashley, D.H.2    Yoshiyama, M.3
  • 75
    • 0141906516 scopus 로고    scopus 로고
    • Effect of one-year waterstorage on the effectiveness of dentin adhesives in Class V composite resin restorations
    • Abstract #946
    • Blunck U, Roulet JF. Effect of one-year waterstorage on the effectiveness of dentin adhesives in Class V composite resin restorations. J Dent Res 2002; 81 (Spec Iss A): A-139, Abstract #946.
    • (2002) J Dent Res , vol.81 , Issue.SPEC. ISSUE A
    • Blunck, U.1    Roulet, J.F.2
  • 78
    • 0038674436 scopus 로고    scopus 로고
    • Interfacial characteristics of resin-modified glass-ionomers bonded to dentin
    • Abstract #1701
    • Van Meerbeek B, Yoshida Y, Inoue S, Fukuda R, Okazaki M, Lambrechts P, Vanherle G. Interfacial characteristics of resin-modified glass-ionomers bonded to dentin. J Dent Res 2001; 80 (Spec Iss): 739, Abstract #1701.
    • (2001) J Dent Res , vol.80 , Issue.SPEC. ISSUE , pp. 739
    • Van Meerbeek, B.1    Yoshida, Y.2    Inoue, S.3    Fukuda, R.4    Okazaki, M.5    Lambrechts, P.6    Vanherle, G.7
  • 79
    • 0035463788 scopus 로고    scopus 로고
    • Effect of remaining dentin thickness and the use of conditioner on micro-tensile bond strength of a glass-ionomer adhesive
    • Inoue S, Van Meerbeek B, Abe Y, Yoshida Y, Lambrechts P, Vanherle G, Sano H. Effect of remaining dentin thickness and the use of conditioner on micro-tensile bond strength of a glass-ionomer adhesive. Dent Mater 2001; 17: 445-455.
    • (2001) Dent Mater , vol.17 , pp. 445-455
    • Inoue, S.1    Van Meerbeek, B.2    Abe, Y.3    Yoshida, Y.4    Lambrechts, P.5    Vanherle, G.6    Sano, H.7
  • 80
    • 0035376148 scopus 로고    scopus 로고
    • Clinical performance of a resin-modified glass-ionomer and a compomer in restoring non-carious cervical lesions. 5-year results
    • Folwaczny M, Mehl A, Kunzelmann KH, Hickel R. Clinical performance of a resin-modified glass-ionomer and a compomer in restoring non-carious cervical lesions. 5-year results. Am J Dent 2001; 14: 153-156.
    • (2001) Am J Dent , vol.14 , pp. 153-156
    • Folwaczny, M.1    Mehl, A.2    Kunzelmann, K.H.3    Hickel, R.4
  • 81
    • 0036727560 scopus 로고    scopus 로고
    • Clinical evaluation of a resin-modified glass-ionomer adhesive system: Results at five years
    • Tyas MJ, Burrow MF. Clinical evaluation of a resin-modified glass-ionomer adhesive system: results at five years. Oper Dent 2002; 27: 438-441.
    • (2002) Oper Dent , vol.27 , pp. 438-441
    • Tyas, M.J.1    Burrow, M.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.