메뉴 건너뛰기




Volumn 7, Issue 3, 2005, Pages 448-455

Real-time glucose sensing using transdermal fluid under continuous vacuum pressure in children with type 1 diabetes

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADOLESCENT; ADULT; ARTICLE; BLOOD GLUCOSE MONITORING; CHILD; CONTROLLED STUDY; DEVICE; DIET RESTRICTION; HUMAN; INSULIN DEPENDENT DIABETES MELLITUS; PHYSICAL ACTIVITY; PRIORITY JOURNAL; SENSOR; VACUUM; WATER IMMERSION;

EID: 20544471864     PISSN: 15209156     EISSN: None     Source Type: Journal    
DOI: 10.1089/dia.2005.7.448     Document Type: Article
Times cited : (16)

References (19)
  • 1
    • 12444301362 scopus 로고    scopus 로고
    • Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum
    • Gebhart S, Faupel M, Fowler R, Kapsner C, Wangsness M, Xu F, Vanstory M: Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum. Diabetes Technol Ther 2003;5:159-166.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 159-166
    • Gebhart, S.1    Faupel, M.2    Fowler, R.3    Kapsner, C.4    Wangsness, M.5    Xu, F.6    Vanstory, M.7
  • 2
    • 0031257640 scopus 로고    scopus 로고
    • Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
    • Bantle JP, Thomas W: Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid. J Lab Clin Med 1997;130:436-441.
    • (1997) J Lab Clin Med , vol.130 , pp. 436-441
    • Bantle, J.P.1    Thomas, W.2
  • 4
    • 0032964848 scopus 로고    scopus 로고
    • Skin mini-erosion technique for monitoring metabolites in interstitial fluid: Its feasibility demonstrated by OGTT results in diabetic and non-diabetic subjects
    • Svedman C, Samra JS, Clark ML, Levy JC, Frayn KN: Skin mini-erosion technique for monitoring metabolites in interstitial fluid: its feasibility demonstrated by OGTT results in diabetic and non-diabetic subjects. Scand J Clin Invest 1999;59:115-123.
    • (1999) Scand J Clin Invest , vol.59 , pp. 115-123
    • Svedman, C.1    Samra, J.S.2    Clark, M.L.3    Levy, J.C.4    Frayn, K.N.5
  • 6
    • 0030879505 scopus 로고    scopus 로고
    • Dermal interstitial glucose as an indicator of ambient glycemia
    • Service, F, O'Brien P, Wise S, Ness S, LeBlanc S: Dermal interstitial glucose as an indicator of ambient glycemia. Diabetes Care 1997;20:1426-1429.
    • (1997) Diabetes Care , vol.20 , pp. 1426-1429
    • Service, F.1    O'Brien, P.2    Wise, S.3    Ness, S.4    LeBlanc, S.5
  • 7
    • 0031257640 scopus 로고    scopus 로고
    • Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
    • Bantle J, Thomas W: Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid. J Lab Clin Med 1997;130:436-441.
    • (1997) J Lab Clin Med , vol.130 , pp. 436-441
    • Bantle, J.1    Thomas, W.2
  • 8
    • 0032964848 scopus 로고    scopus 로고
    • Skin mini-erosion technique for monitoring metabolites in interstitial fluid: Its feasibility demonstrated by OGTT results in diabetic and non-diabetic subjects
    • Svedman C, Samra J, Clark M, Levy J, Frayn K: Skin mini-erosion technique for monitoring metabolites in interstitial fluid: Its feasibility demonstrated by OGTT results in diabetic and non-diabetic subjects. Scand J Clin Lab Invest 1999;59:115-124.
    • (1999) Scand J Clin Lab Invest , vol.59 , pp. 115-124
    • Svedman, C.1    Samra, J.2    Clark, M.3    Levy, J.4    Frayn, K.5
  • 10
    • 0030985974 scopus 로고    scopus 로고
    • Reservations on the use of Error Grid Analysis for the validation of blood glucose assays
    • Gough D, Botvinick E: Reservations on the use of Error Grid Analysis for the validation of blood glucose assays. Diabetes Care 1997;20:1034-1036.
    • (1997) Diabetes Care , vol.20 , pp. 1034-1036
    • Gough, D.1    Botvinick, E.2
  • 11
    • 0034949984 scopus 로고    scopus 로고
    • Long hypoglycemic periods detected by subcutaneous glucose monitoring in toddlers and preschool children with diabetes mellitus
    • Deiss D, Kordonouri O, Meyer K, Danne T: Long hypoglycemic periods detected by subcutaneous glucose monitoring in toddlers and preschool children with diabetes mellitus [letter]. Diabet Med 2001;18:337-338.
    • (2001) Diabet Med , vol.18 , pp. 337-338
    • Deiss, D.1    Kordonouri, O.2    Meyer, K.3    Danne, T.4
  • 12
    • 0042490765 scopus 로고    scopus 로고
    • The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving control
    • Chico A, Subira M, Vidal-Rios P, Novials A: The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving control. Diabetes Care 2003;26:1153-1157.
    • (2003) Diabetes Care , vol.26 , pp. 1153-1157
    • Chico, A.1    Subira, M.2    Vidal-Rios, P.3    Novials, A.4
  • 14
    • 0038643466 scopus 로고    scopus 로고
    • Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: A controlled crossover study
    • Ludvigsson J, Hanas R: Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: A controlled crossover study. Pediatrics 2003;111:933-938.
    • (2003) Pediatrics , vol.111 , pp. 933-938
    • Ludvigsson, J.1    Hanas, R.2
  • 15
    • 0032754795 scopus 로고    scopus 로고
    • Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: A pilot study
    • Bode BW, Gross TM, Thornton KR, Mastrototaro JJ: Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: A pilot study. Diabetes Res Clin Pract 1999;46:183-190.
    • (1999) Diabetes Res Clin Pract , vol.46 , pp. 183-190
    • Bode, B.W.1    Gross, T.M.2    Thornton, K.R.3    Mastrototaro, J.J.4
  • 16
    • 0242363717 scopus 로고    scopus 로고
    • A continuous glucose sensor based on wired enzyme technology-results from a 3-day trial in patients with type 1 diabetes
    • Feldman B, Brazg R, Schwartz S, Weinstein R: A continuous glucose sensor based on wired enzyme technology-results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol Ther 2003;5: 769-779.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 769-779
    • Feldman, B.1    Brazg, R.2    Schwartz, S.3    Weinstein, R.4
  • 17
    • 1442275324 scopus 로고    scopus 로고
    • Accuracy of the GlucoWatch G2 biographer and the continuous glucose monitoring System during hypoglycemia
    • The Diabetes Research in Children Network (Direc-Net) Study Group: Accuracy of the GlucoWatch G2 Biographer and the Continuous Glucose Monitoring System during hypoglycemia. Diabetes Care 2004; 27:722-726.
    • (2004) Diabetes Care , vol.27 , pp. 722-726
  • 18
    • 1442324399 scopus 로고    scopus 로고
    • Improved glucose excursions using an implantable real-time continuous sensor in adults with type 1 diabetes
    • Garg SK, Schwartz S, Edelman SV: Improved glucose excursions using an implantable real-time continuous sensor in adults with type 1 diabetes. Diabetes Care 2004;27:734-738.
    • (2004) Diabetes Care , vol.27 , pp. 734-738
    • Garg, S.K.1    Schwartz, S.2    Edelman, S.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.