메뉴 건너뛰기




Volumn 149, Issue 6, 2005, Pages 1136.e1-1136.e7

Embolic protection during saphenous vein graft intervention using a second-generation balloon protection device: Results from the combined US and European pilot study of the TriActiv Balloon Protected Flush Extraction System

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ASPIRATION; ATHEROSCLEROTIC PLAQUE; CARDIOVASCULAR RISK; DEVICE; EMBOLISM; FEMALE; HEART INFARCTION; HUMAN; MAJOR CLINICAL STUDY; MALE; PILOT STUDY; PRIORITY JOURNAL; Q WAVE; SAPHENOUS VEIN GRAFT; STENT;

EID: 20544464196     PISSN: 00028703     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ahj.2004.12.024     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 0027231803 scopus 로고
    • Balloon angioplasty for the treatment of lesions in saphenous vein bypass grafts
    • P.J. de Feyter, R.J. van Suylen, and P.P. de Jaegere Balloon angioplasty for the treatment of lesions in saphenous vein bypass grafts J. Am. Coll. Cardiol. 21 1993 1539 1549
    • (1993) J. Am. Coll. Cardiol. , vol.21 , pp. 1539-1549
    • De Feyter, P.J.1    Van Suylen, R.J.2    De Jaegere, P.P.3
  • 2
    • 0026028332 scopus 로고
    • The Dutch experience in percutaneous transluminal angioplasty of narrowed saphenous veins used for aortocoronary arterial bypass
    • H.W.T. Plokker, B.H. Meester, and P.W. Serruys The Dutch experience in percutaneous transluminal angioplasty of narrowed saphenous veins used for aortocoronary arterial bypass Am. J. Cardiol. 67 1991 361 363
    • (1991) Am. J. Cardiol. , vol.67 , pp. 361-363
    • Plokker, H.W.T.1    Meester, B.H.2    Serruys, P.W.3
  • 3
    • 9844257578 scopus 로고    scopus 로고
    • Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts. Saphenous Vein de Novo Trial Investigators
    • M.P. Savage, J.S. Douglas Jr., and D.L. Fischman Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts. Saphenous Vein De Novo Trial Investigators N. Engl. J. Med. 337 1997 740 747
    • (1997) N. Engl. J. Med. , vol.337 , pp. 740-747
    • Savage, M.P.1    Douglas Jr., J.S.2    Fischman, D.L.3
  • 4
    • 0032786887 scopus 로고    scopus 로고
    • Creatinine kinase-MB enzyme elevation following successful saphenous vein intervention is associated with late mortality
    • M.K. Hong, R. Mehran, and G. Dangas Creatinine kinase-MB enzyme elevation following successful saphenous vein intervention is associated with late mortality Circulation 100 1999 2400 2405
    • (1999) Circulation , vol.100 , pp. 2400-2405
    • Hong, M.K.1    Mehran, R.2    Dangas, G.3
  • 5
    • 0036467897 scopus 로고    scopus 로고
    • A trial comparing rheolytic thrombectomy with intracoronary urokinase for coronary and vein graft thrombus (the Vein Graft AngioJet Study [VeGAS 2])
    • R.E. Kuntz, D.S. Baim, and D.J. Cohen A trial comparing rheolytic thrombectomy with intracoronary urokinase for coronary and vein graft thrombus (the Vein Graft AngioJet Study [VeGAS 2]) Am. J. Cardiol. 89 2002 326 330
    • (2002) Am. J. Cardiol. , vol.89 , pp. 326-330
    • Kuntz, R.E.1    Baim, D.S.2    Cohen, D.J.3
  • 6
    • 0028944641 scopus 로고
    • A multicenter, randomized trial of coronary angioplasty versus directional atherectomy for patients with saphenous vein graft lesions. CAVEAT-II Investigators
    • D.R. Holmes, E.J. Topol, and R.M. Califf A multicenter, randomized trial of coronary angioplasty versus directional atherectomy for patients with saphenous vein graft lesions. CAVEAT-II Investigators Circulation 91 1995 1966 1974
    • (1995) Circulation , vol.91 , pp. 1966-1974
    • Holmes, D.R.1    Topol, E.J.2    Califf, R.M.3
  • 7
    • 0037058871 scopus 로고    scopus 로고
    • Lack of benefit from intravenous platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment for percutaneous interventions of aortocoronary bypass grafts
    • M. Roffi, D. Mukherjee, and D.P. Chew Lack of benefit from intravenous platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment for percutaneous interventions of aortocoronary bypass grafts Circulation 106 2002 3063 3067
    • (2002) Circulation , vol.106 , pp. 3063-3067
    • Roffi, M.1    Mukherjee, D.2    Chew, D.P.3
  • 8
    • 0038164591 scopus 로고    scopus 로고
    • Randomized evaluation of polytetrafluoroethylene-covered stent in saphenous vein grafts: The randomized evaluation of polytetrafluoroethylene COVERed stent in saphenous vein grafts (RECOVERS) trial
    • G. Stankovic, A. Colombo, and P. Presbitero Randomized evaluation of polytetrafluoroethylene-covered stent in saphenous vein grafts: the randomized evaluation of polytetrafluoroethylene COVERed stent in saphenous vein grafts (RECOVERS) trial Circulation 108 2003 37 42
    • (2003) Circulation , vol.108 , pp. 37-42
    • Stankovic, G.1    Colombo, A.2    Presbitero, P.3
  • 9
    • 0028363689 scopus 로고
    • Predictors of outcome of percutaneous excimer angioplasty of saphenous vein bypass graft lesions
    • J.A. Bittl, T.A. Sanborn, and D.E. Yardley Predictors of outcome of percutaneous excimer angioplasty of saphenous vein bypass graft lesions Am. J. Cardiol. 74 1994 144 148
    • (1994) Am. J. Cardiol. , vol.74 , pp. 144-148
    • Bittl, J.A.1    Sanborn, T.A.2    Yardley, D.E.3
  • 10
    • 0032742941 scopus 로고    scopus 로고
    • Retrieval and analysis of particulate debris after saphenous vein graft intervention
    • J.G. Webb, R.G. Carere, and R. Virmani Retrieval and analysis of particulate debris after saphenous vein graft intervention J. Am. Coll. Cardiol. 34 1999 468 475
    • (1999) J. Am. Coll. Cardiol. , vol.34 , pp. 468-475
    • Webb, J.G.1    Carere, R.G.2    Virmani, R.3
  • 11
    • 0037133682 scopus 로고    scopus 로고
    • Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts
    • D.S. Baim, D. Wahr, and B. George Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts Circulation 105 2002 1285 1290
    • (2002) Circulation , vol.105 , pp. 1285-1290
    • Baim, D.S.1    Wahr, D.2    George, B.3
  • 12
    • 0037145803 scopus 로고    scopus 로고
    • Distal filter protection during saphenous vein graft stenting: Technical and clinical correlates of efficacy
    • G.W. Stone, C. Rogers, and S. Ramee Distal filter protection during saphenous vein graft stenting: technical and clinical correlates of efficacy J. Am. Coll. Cardiol. 40 2002 1882 1888
    • (2002) J. Am. Coll. Cardiol. , vol.40 , pp. 1882-1888
    • Stone, G.W.1    Rogers, C.2    Ramee, S.3
  • 13
    • 0043075814 scopus 로고    scopus 로고
    • Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts
    • G.W. Stone, C. Rogers, and J. Hermiller Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts Circulation 108 2003 548 553
    • (2003) Circulation , vol.108 , pp. 548-553
    • Stone, G.W.1    Rogers, C.2    Hermiller, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.