Long-term vitreous replacement with perfluorohexyloctane and silicone oil: Preliminary reports of a multicentric study

Author keywords

Long term vitreous replacement; Perfluorohexyloctane (F6H 8); Silicone oil

Indexed keywords

PERFLUOROHEXYLOCTANE; SILICONE OIL; SODIUM CHLORIDE; FLUOROCARBON; PERFLUOROHEXYL OCTAN; PERFLUOROHEXYL-OCTAN;

EID: 20544456365     PISSN: 00303755     EISSN: None     Source Type: Journal    
DOI: 10.1159/000085247     Document Type: Article
Times cited : (16)

References (23)
  • 1
    • 0025996535 scopus 로고
    • Long-term vitreous replacement in primates with intravitreal Vitreon or Vitreon plus silicone
    • Peyman GA, Conway MD, Soike KF, Clark LC: Long-term vitreous replacement in primates with intravitreal Vitreon or Vitreon plus silicone. Ophthalmic Surg 1991;22:657-664.
    • (1991) Ophthalmic Surg , vol.22 , pp. 657-664
    • Peyman, G.A.1    Conway, M.D.2    Soike, K.F.3    Clark, L.C.4
  • 2
    • 0026731971 scopus 로고
    • The effect of simultaneous internal tamponade on fluid compartmentalization and its relationship to cell proliferation
    • De Molfetta V, Bottoni F, Arpa P, Vinciguerra P, Zenoni S: The effect of simultaneous internal tamponade on fluid compartmentalization and its relationship to cell proliferation. Retina 1992;12:S40-S45.
    • (1992) Retina , vol.12
    • De Molfetta, V.1    Bottoni, F.2    Arpa, P.3    Vinciguerra, P.4    Zenoni, S.5
  • 3
    • 0026624957 scopus 로고
    • Experimental studies of the combined use of vitreous substitutes of high and low specific gravity
    • Sparrow JR, Jayakumar A, Berrocal M, Ozmert E, Chang S: Experimental studies of the combined use of vitreous substitutes of high and low specific gravity. Retina 1992;12:134-140.
    • (1992) Retina , vol.12 , pp. 134-140
    • Sparrow, J.R.1    Jayakumar, A.2    Berrocal, M.3    Ozmert, E.4    Chang, S.5
  • 4
    • 0031814901 scopus 로고    scopus 로고
    • Experimental short-term tolerance to perfluorodecalin in the rabbit eye: A histopathological study
    • Orzalesi N, Migliavacca L, Bottoni F, Miglior S: Experimental short-term tolerance to perfluorodecalin in the rabbit eye: A histopathological study. Curr Eye Res 1998;17:828-835.
    • (1998) Curr Eye Res , vol.17 , pp. 828-835
    • Orzalesi, N.1    Migliavacca, L.2    Bottoni, F.3    Miglior, S.4
  • 5
    • 0033304089 scopus 로고    scopus 로고
    • Perfluorohexyloctane as a long-term vitreous tamponade in the experimental animal: Experimental perfluorohexyloctane substitution
    • Zeana D, Becker J, Kuckelkorn R, Kirchhof B: Perfluorohexyloctane as a long-term vitreous tamponade in the experimental animal: Experimental perfluorohexyloctane substitution. Int Ophthalmol 1999;23:17-24.
    • (1999) Int Ophthalmol , vol.23 , pp. 17-24
    • Zeana, D.1    Becker, J.2    Kuckelkorn, R.3    Kirchhof, B.4
  • 6
    • 0001566996 scopus 로고    scopus 로고
    • Fluorcarbone in der Netzhaut-Glaskörperchirurgie
    • Kirchhof B: Fluorcarbone in der Netzhaut-Glaskörperchirurgie. Ophthalmochirurgie 1999;11:153-158.
    • (1999) Ophthalmochirurgie , vol.11 , pp. 153-158
    • Kirchhof, B.1
  • 7
    • 0036146936 scopus 로고    scopus 로고
    • Use of perfluorohexyloctane as a long-term internal tamponade agent in complicated retinal detachment surgery
    • Kirchhof B, Wong D, Van Meurs J, Hilgers RD, Macek M, Lois N, Schrage NF: Use of perfluorohexyloctane as a long-term internal tamponade agent in complicated retinal detachment surgery. Am J Ophthalmol 2002;133:95-101.
    • (2002) Am J Ophthalmol , vol.133 , pp. 95-101
    • Kirchhof, B.1    Wong, D.2    Van Meurs, J.3    Hilgers, R.D.4    Macek, M.5    Lois, N.6    Schrage, N.F.7
  • 8
    • 0035130559 scopus 로고    scopus 로고
    • Clinicopathologjcal correlation of epiretinal membranes and posterior lens opacification following perfluorohexyloctane tamponade
    • Hiscott P, Magee RM, Colthurst M, Lois N, Wong D: Clinicopathologjcal correlation of epiretinal membranes and posterior lens opacification following perfluorohexyloctane tamponade. Br J Ophthalmol 2001;85:179-183.
    • (2001) Br J Ophthalmol , vol.85 , pp. 179-183
    • Hiscott, P.1    Magee, R.M.2    Colthurst, M.3    Lois, N.4    Wong, D.5
  • 11
    • 0020657567 scopus 로고
    • The classification of retinal detachment with proliferative vitreoretinopathy
    • Anonymous: The classification of retinal detachment with proliferative vitreoretinopathy. Ophthalmology 1983;90:121-125.
    • (1983) Ophthalmology , vol.90 , pp. 121-125
  • 12
    • 0013833492 scopus 로고
    • Rilievi biometrici sulla lunghezza dei vari assi oculari e sul volume del bulbo eseguiti col metodo ecografico
    • Rivara A, Zingirian M: Rilievi biometrici sulla lunghezza dei vari assi oculari e sul volume del bulbo eseguiti col metodo ecografico. Ann Oftalmol Clin Ocul 1965;91:1233-1238.
    • (1965) Ann Oftalmol Clin Ocul , vol.91 , pp. 1233-1238
    • Rivara, A.1    Zingirian, M.2
  • 13
    • 0036956450 scopus 로고    scopus 로고
    • Evidence of toxic side effects of perfluorohexyloctane after vitreoretinal surgery as well as in previously established in vitro models with ocular cell types
    • Mertens S, Bednarz J, Engelmann K: Evidence of toxic side effects of perfluorohexyloctane after vitreoretinal surgery as well as in previously established in vitro models with ocular cell types. Graefes Arch Clin Exp Ophthalmol 2002;240:989-995.
    • (2002) Graefes Arch Clin Exp Ophthalmol , vol.240 , pp. 989-995
    • Mertens, S.1    Bednarz, J.2    Engelmann, K.3
  • 15
    • 1842627632 scopus 로고    scopus 로고
    • Tamponade properties of double-filling with perfluorohexyloctane and silicone oil in a model eye chamber
    • Herbert E, Stappler T, Wetterquist C, Williams R, Wong D: Tamponade properties of double-filling with perfluorohexyloctane and silicone oil in a model eye chamber. Graefes Arch Clin Exp Ophthalmol 2004;242:250-254.
    • (2004) Graefes Arch Clin Exp Ophthalmol , vol.242 , pp. 250-254
    • Herbert, E.1    Stappler, T.2    Wetterquist, C.3    Williams, R.4    Wong, D.5
  • 16
    • 0036947951 scopus 로고    scopus 로고
    • Clinical findings on the use of long-term heavy tamponades (semifluorinated alkanes and their oligomers) in complicated retinal detachment surgery
    • Roider J, Hoerauf H, Kobuch K, Gabel VP: Clinical findings on the use of long-term heavy tamponades (semifluorinated alkanes and their oligomers) in complicated retinal detachment surgery. Graefes Arch Clin Exp Ophthalmol 2002;240:965-971.
    • (2002) Graefes Arch Clin Exp Ophthalmol , vol.240 , pp. 965-971
    • Roider, J.1    Hoerauf, H.2    Kobuch, K.3    Gabel, V.P.4
  • 17
    • 0026778157 scopus 로고
    • Prognostic value of new retinal tears associated with the development of postoperative proliferative vitreoretinopathy
    • Fleury J, Bonnet M: Prognostic value of new retinal tears associated with the development of postoperative proliferative vitreoretinopathy. Graefes Arch Clin Exp Ophthalmol 1992;230:459-462.
    • (1992) Graefes Arch Clin Exp Ophthalmol , vol.230 , pp. 459-462
    • Fleury, J.1    Bonnet, M.2
  • 18
    • 0022512550 scopus 로고
    • Silicone oil for advanced proliferative vitreoretinopathy
    • Cox MS, Trese MT, Murphy PL: Silicone oil for advanced proliferative vitreoretinopathy. Ophthalmology 1986;93:646-650.
    • (1986) Ophthalmology , vol.93 , pp. 646-650
    • Cox, M.S.1    Trese, M.T.2    Murphy, P.L.3
  • 19
    • 0026529301 scopus 로고
    • Combined silicone and fluorosilicone oil tamponade (double filling) in the management of complicated retinal detachment
    • Bottoni F, Arpa P, Vinciguerra P, Zenoni S, De Molfetta V: Combined silicone and fluorosilicone oil tamponade (double filling) in the management of complicated retinal detachment. Ophthalmologjca 1992;204:77-81.
    • (1992) Ophthalmologjca , vol.204 , pp. 77-81
    • Bottoni, F.1    Arpa, P.2    Vinciguerra, P.3    Zenoni, S.4    De Molfetta, V.5
  • 20
    • 0034811028 scopus 로고    scopus 로고
    • Retinal redetachment after removal of intraocular silicone oil tamponade
    • Jonas JB, Knorr HLJ, Rank RM, Budde WM: Retinal redetachment after removal of intraocular silicone oil tamponade. Br J Ophthalmol 2001;85:1203-1207.
    • (2001) Br J Ophthalmol , vol.85 , pp. 1203-1207
    • Jonas, J.B.1    Knorr, H.L.J.2    Rank, R.M.3    Budde, W.M.4
  • 23
    • 0027431174 scopus 로고
    • Perfluoroperhydrophenanthrene (Vitreon) as a short-term vitreous substitute after complex vitreoretinal surgery
    • Tanji TM, Peyman GA, Mehta NJ, Millsap CM: Perfluoroperhydrophenanthrene (Vitreon) as a short-term vitreous substitute after complex vitreoretinal surgery. Ophthalmic Surg 1993;24:681-685.
    • (1993) Ophthalmic Surg , vol.24 , pp. 681-685
    • Tanji, T.M.1    Peyman, G.A.2    Mehta, N.J.3    Millsap, C.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.