메뉴 건너뛰기




Volumn 41, Issue 3, 2005, Pages 784-789

Model-based detection of rotor faults without rotor position sensor - The sensorless vienna monitoring method

Author keywords

Diagnostics; Electrical rotor asymmetry; Fault detection; Induction machine; Model; Monitoring; Rotor fault; Squirrel cage; Torque; Without speed sensor

Indexed keywords

ELECTRIC CURRENTS; ELECTRIC DRIVES; ELECTRIC FAULT CURRENTS; ELECTRIC POTENTIAL; INDUCTION MOTORS; LOW PASS FILTERS; MATHEMATICAL MODELS; SQUIRREL CAGE MOTORS; TORQUE;

EID: 20544452307     PISSN: 00939994     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIA.2005.847316     Document Type: Article
Times cited : (30)

References (17)
  • 1
    • 0030421774 scopus 로고    scopus 로고
    • "Evaluation and implementation of a system to eliminate arbitrary load effects in current-based monitoring of induction machines"
    • R. Schoen and T. Habetler, "Evaluation and implementation of a system to eliminate arbitrary load effects in current-based monitoring of induction machines," in Conf Rec. IEEE-IAS Annu. Meeting, 1996, pp. 6714578.
    • (1996) Conf Rec. IEEE-IAS Annu. Meeting , pp. 671-678
    • Schoen, R.1    Habetler, T.2
  • 2
    • 0033317468 scopus 로고    scopus 로고
    • "Study of three phase induction motors with incipient rotor cage faults under different supply conditions"
    • S. Nandi, R. Bharadwaj, H. Toliyat, and A. Parlos, "Study of three phase induction motors with incipient rotor cage faults under different supply conditions," in Conf. Rec. IEEE-IAS Annu. Meeting, vol. 3, 1999, pp. 1922-1928.
    • (1999) Conf. Rec. IEEE-IAS Annu. Meeting , vol.3 , pp. 1922-1928
    • Nandi, S.1    Bharadwaj, R.2    Toliyat, H.3    Parlos, A.4
  • 3
    • 0035396689 scopus 로고    scopus 로고
    • "Current signature analysis to detect induction motor faults"
    • Jan./Feb
    • W. Thomson and M. Fenger, "Current signature analysis to detect induction motor faults," IEEE Ind. Appl. Mag., vol. 7, no. 1, pp. 26-34, Jan./Feb. 2001.
    • (2001) IEEE Ind. Appl. Mag. , vol.7 , Issue.1 , pp. 26-34
    • Thomson, W.1    Fenger, M.2
  • 5
    • 0037920847 scopus 로고
    • "On-line condition monitoring of defects in squirrel cage motors"
    • R. Hirvonen, "On-line condition monitoring of defects in squirrel cage motors," in Proc. ICEM'94, 1994, pp. 267-272.
    • (1994) Proc. ICEM'94 , pp. 267-272
    • Hirvonen, R.1
  • 6
    • 0027806807 scopus 로고
    • "Effects of time-varying load on rotor fault detection in induction machines"
    • R. Schoen and T. Habetler, "Effects of time-varying load on rotor fault detection in induction machines," in Conf. Rec. IEEE-IAS Annu. Meeting, 1993, pp. 324-330.
    • (1993) Conf. Rec. IEEE-IAS Annu. Meeting , pp. 324-330
    • Schoen, R.1    Habetler, T.2
  • 8
    • 0030195155 scopus 로고    scopus 로고
    • "Instantaneous power as a medium for the signature analysis of induction motors"
    • May/Jun
    • S. Legowski, A. S. Ula, and A. Trzynadlowski, "Instantaneous power as a medium for the signature analysis of induction motors," IEEE Trans. Ind. Appl., vol. 32, no. 4, pp. 904-909, May/Jun. 1996.
    • (1996) IEEE Trans. Ind. Appl. , vol.32 , Issue.4 , pp. 904-909
    • Legowski, S.1    Ula, A.S.2    Trzynadlowski, A.3
  • 9
    • 0033316663 scopus 로고    scopus 로고
    • "Rotor cage fault diagnosis in three-phase induction motors by the total instantaneous power spectral analysis"
    • S. Cruz and A. Cardoso, "Rotor cage fault diagnosis in three-phase induction motors by the total instantaneous power spectral analysis," in Conf. Rec. IEEE-IAS Annu. Meeting, vol. 3, 1999, pp. 1929-1934.
    • (1999) Conf. Rec. IEEE-IAS Annu. Meeting , vol.3 , pp. 1929-1934
    • Cruz, S.1    Cardoso, A.2
  • 10
    • 0034297535 scopus 로고    scopus 로고
    • "Comparative investigation of diagnostic media for induction motors: A case of rotor cage faults"
    • Oct
    • A. Trzynadlowski and E. Ritchie, "Comparative investigation of diagnostic media for induction motors: A case of rotor cage faults," IEEE Trans. Ind. Electron., vol. 47, no. 5, pp. 1092-1099, Oct. 2000.
    • (2000) IEEE Trans. Ind. Electron. , vol.47 , Issue.5 , pp. 1092-1099
    • Trzynadlowski, A.1    Ritchie, E.2
  • 11
    • 0009745740 scopus 로고    scopus 로고
    • "On-line rotor cage monitoring of inverter fed induction machines, experimental results"
    • R. Wieser, C. Kral, F. Pirker, and M. Schagginger, "On-line rotor cage monitoring of inverter fed induction machines, experimental results," in Proc. SDEMPED'97, 1997, pp. 15-22.
    • (1997) Proc. SDEMPED'97 , pp. 15-22
    • Wieser, R.1    Kral, C.2    Pirker, F.3    Schagginger, M.4
  • 12
    • 0003388663 scopus 로고    scopus 로고
    • "High sensitive rotor cage monitoring during dynamic load operation the Vienna monitoring method"
    • R. Wieser, C. Kral, F. Pirker, and M. Schagginger, "High sensitive rotor cage monitoring during dynamic load operation the Vienna monitoring method," in Proc. ICEM'98, 1998, pp. 432-437.
    • (1998) Proc. ICEM'98 , pp. 432-437
    • Wieser, R.1    Kral, C.2    Pirker, F.3    Schagginger, M.4
  • 13
    • 20544439469 scopus 로고    scopus 로고
    • "Influence of load torque on rotor asymmetry effects in squirrel cage induction machines including detection by means of the Vienna Monitoring Method"
    • CD-ROM
    • C. Kral, F. Pirker, and G. Pascoli, "Influence of load torque on rotor asymmetry effects in squirrel cage induction machines including detection by means of the Vienna Monitoring Method," in Proc. EPE'0I, 2001, CD-ROM.
    • (2001) Proc. EPE'01
    • Kral, C.1    Pirker, F.2    Pascoli, G.3
  • 14
    • 17044387912 scopus 로고    scopus 로고
    • "Influence of inertia on general effects of faulty rotor bars and the Vienna monitoring method"
    • C. Kral, F. Pirker, and G. Pascoli, "Influence of inertia on general effects of faulty rotor bars and the Vienna monitoring method," in Proc. SDEMPED'01, 2001, pp. 447-452.
    • (2001) Proc. SDEMPED'01 , pp. 447-452
    • Kral, C.1    Pirker, F.2    Pascoli, G.3
  • 15
    • 0032307067 scopus 로고    scopus 로고
    • "The Vienna induction machine monitoring method; on the impact of the field oriented control structure on real operational behavior of a faulty machine"
    • R. Wieser, C. Kral, F. Pirker, and M. Schagginger, "The Vienna induction machine monitoring method; on the impact of the field oriented control structure on real operational behavior of a faulty machine," in Proc. IEEE IECON'98, 1998, pp. 1544-1549.
    • (1998) Proc. IEEE IECON'98 , pp. 1544-1549
    • Wieser, R.1    Kral, C.2    Pirker, F.3    Schagginger, M.4
  • 17
    • 20544432630 scopus 로고    scopus 로고
    • "Influence of rotor cage design on rotor fault detection by means of the vienna monitoring method"
    • CD-ROM
    • C. Kral, F. Pirker, G. Pascoli, and H. Oberguggenberger, "Influence of rotor cage design on rotor fault detection by means of the vienna monitoring method," in Proc. ICEM'02, 2002, CD-ROM.
    • (2002) Proc. ICEM'02
    • Kral, C.1    Pirker, F.2    Pascoli, G.3    Oberguggenberger, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.