메뉴 건너뛰기




Volumn 54, Issue 3, 2005, Pages 1171-1174

Integrated temperature sensor for determination of ultrasound interstitial applicator heating effects

Author keywords

Medical instrumentation; Medical measurement; Temperature sensor; Thermal therapy instrumentation; Ultrasonic transducers

Indexed keywords

ANTENNAS; FINITE ELEMENT METHOD; MEDICAL APPLICATIONS; TEMPERATURE MEASUREMENT; THERMAL EFFECTS; THERMISTORS; ULTRASONIC TRANSDUCERS; WAVEGUIDES;

EID: 20544449232     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2005.847117     Document Type: Article
Times cited : (6)

References (17)
  • 1
    • 0036148615 scopus 로고    scopus 로고
    • "The Dutch deep hyperthermia trial: Results in cervical cancer"
    • J. van der Zee and D. Gonzales-Gonzales, "The Dutch deep hyperthermia trial: Results in cervical cancer," Int. J. Hyperthermia, vol. 18, pp. 1-12, 2002.
    • (2002) Int. J. Hyperthermia , vol.18 , pp. 1-12
    • van der Zee, J.1    Gonzales-Gonzales, D.2
  • 2
    • 0032965735 scopus 로고    scopus 로고
    • "Quantifying tissue damage due to focused ultrasound heating observed by MRI"
    • S. J. Graham et al., "Quantifying tissue damage due to focused ultrasound heating observed by MRI," Magn. Res. Med, vol. 41, pp. 321-328, 1999.
    • (1999) Magn. Res. Med. , vol.41 , pp. 321-328
    • Graham, S.J.1
  • 3
    • 0032442138 scopus 로고    scopus 로고
    • "A 3-D finite element model for computation of temperature profiles and regions of thermal damage during focused ultrasound surgery exposure"
    • P. M. Meaney et al., "A 3-D finite element model for computation of temperature profiles and regions of thermal damage during focused ultrasound surgery exposure," Ultrasound Med. Biol., vol. 24, pp. 1489-1499, 1998.
    • (1998) Ultrasound Med. Biol. , vol.24 , pp. 1489-1499
    • Meaney, P.M.1
  • 4
    • 0141638519 scopus 로고    scopus 로고
    • "Polyacrylamide gel as an acoustic coupling medium for focused ultrasound therapy"
    • A. F. Prokop et al., "Polyacrylamide gel as an acoustic coupling medium for focused ultrasound therapy," Ultrasound Med. Biol., vol. 29, pp. 1351-1358, 2003.
    • (2003) Ultrasound Med. Biol. , vol.29 , pp. 1351-1358
    • Prokop, A.F.1
  • 6
    • 0041411671 scopus 로고    scopus 로고
    • "High power transcranial beam steering for ultrasound brain therapy"
    • M. Pemot et al., "High power transcranial beam steering for ultrasound brain therapy," Phys. Med. Biol., vol. 48, pp. 2577-2589, 2003.
    • (2003) Phys. Med. Biol. , vol.48 , pp. 2577-2589
    • Pemot, M.1
  • 8
    • 0029970915 scopus 로고    scopus 로고
    • "Feasibility of ultrasound hyperthermia with waveguide interstitial applicator"
    • Nov
    • B. J. Jarosz, "Feasibility of ultrasound hyperthermia with waveguide interstitial applicator," IEEE Trans. Biomed. Eng., vol. 43, no. 11, pp. 1108-1115, Nov. 1996.
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , Issue.11 , pp. 1108-1115
    • Jarosz, B.J.1
  • 9
    • 0032083599 scopus 로고    scopus 로고
    • "Ultrasonic heating with waveguide interstitial applicator array"
    • Jun
    • B. J. Jarosz and D. Kaytar, "Ultrasonic heating with waveguide interstitial applicator array," IEEE Trans. Instrum. Meas., vol. 47, no. 3, pp. 703-707, Jun. 1998.
    • (1998) IEEE Trans. Instrum. Meas. , vol.47 , Issue.3 , pp. 703-707
    • Jarosz, B.J.1    Kaytar, D.2
  • 10
    • 0038651521 scopus 로고    scopus 로고
    • "Combination of transurethral and interstitial applicators for high temperature prostate thermal therapy"
    • C. Diederich et al., "Combination of transurethral and interstitial applicators for high temperature prostate thermal therapy," Int. J. Hyperthermia, vol. 41, pp. 321-328, 1999.
    • (1999) Int. J. Hyperthermia , vol.41 , pp. 321-328
    • Diederich, C.1
  • 11
    • 0036222555 scopus 로고    scopus 로고
    • "Ultrasound monitoring of temeprature change during radiofrequency ablation: Preliminary in vivo results,"
    • T. Varghese et al., "Ultrasound monitoring of temeprature change during radiofrequency ablation: Preliminary in vivo results," Ultrasound Med. Biol., vol. 28, pp. 321-329, 2002.
    • (2002) Ultrasound Med. Biol. , vol.28 , pp. 321-329
    • Varghese, T.1
  • 12
    • 0034534760 scopus 로고    scopus 로고
    • "Comparison of thermal damage using magnetic resonance thermometry with magnetic resonance imaging post treatment and histology, after interstitial microwave thermal treatment of rabbit brain"
    • M. D. Sherar et al., "Comparison of thermal damage using magnetic resonance thermometry with magnetic resonance imaging post treatment and histology, after interstitial microwave thermal treatment of rabbit brain," Phys. Med. Biol., vol. 45, pp. 3563-3576, 2000.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3563-3576
    • Sherar, M.D.1
  • 13
    • 0035739578 scopus 로고    scopus 로고
    • "Interstitial ultrasound heating applicator for MR-guided thermal therapy"
    • R. Chopra, C. Luginbuhl, A. J. Weymouth, F. S. Foster, and M. Bronskill, "Interstitial ultrasound heating applicator for MR-guided thermal therapy," Phys. Med. Biol., vol. 46, pp. 3133-3145, 2001.
    • (2001) Phys. Med. Biol. , vol.46 , pp. 3133-3145
    • Chopra, R.1    Luginbuhl, C.2    Weymouth, A.J.3    Foster, F.S.4    Bronskill, M.5
  • 14
    • 0035001217 scopus 로고    scopus 로고
    • "Control system for an MRI compatible intracavitary ultrasound array for thermal treatment of prostate disease"
    • N. B. Smith, N. K. Merrilees, M. Dahleh, and K. Hynynen, "Control system for an MRI compatible intracavitary ultrasound array for thermal treatment of prostate disease," Int. J. Hyperthermia, vol. 17, pp. 271-282, 2001.
    • (2001) Int. J. Hyperthermia , vol.17 , pp. 271-282
    • Smith, N.B.1    Merrilees, N.K.2    Dahleh, M.3    Hynynen, K.4
  • 15
    • 0030996819 scopus 로고    scopus 로고
    • "Thermal effects of focused ultrasoundon the brain: Determination with MR Imaging"
    • K. Hynynen et al., "Thermal effects of focused ultrasoundon the brain: Determination with MR Imaging," Radiology, vol. 204, pp. 247-253, 1997.
    • (1997) Radiology , vol.204 , pp. 247-253
    • Hynynen, K.1
  • 16
    • 20544459065 scopus 로고    scopus 로고
    • "Intrnal Rep."
    • M.Sc. thesis, Carleton Univ., Ottawa, ON, Canada
    • J. Winter, "Intrnal Rep.," M.Sc. thesis, Carleton Univ., Ottawa, ON, Canada, 2002.
    • (2002)
    • Winter, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.