메뉴 건너뛰기




Volumn 67, Issue 1, 2005, Pages 23-35

Investigation of novel mediators for a glucose biosensor based on metal picolinate complexes

Author keywords

Biosensor; Electrocatalysis; Mediator

Indexed keywords

CARBOXYLIC ACIDS; ELECTROCHEMISTRY; ELECTROLYSIS; ENZYMES; GLUCOSE SENSORS; SYNTHESIS (CHEMICAL);

EID: 20444447014     PISSN: 15675394     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bioelechem.2004.07.005     Document Type: Article
Times cited : (24)

References (29)
  • 2
    • 0032281882 scopus 로고    scopus 로고
    • Amperometric glucose sensors fabricated by electrochemical polymerisation of phenols on carbon paste electrodes
    • Y. Nakabayashi, M. Wakuda, and H. Imal Amperometric glucose sensors fabricated by electrochemical polymerisation of phenols on carbon paste electrodes Anal. Sci. 14 1998 1069 1076
    • (1998) Anal. Sci. , vol.14 , pp. 1069-1076
    • Nakabayashi, Y.1    Wakuda, M.2    Imal, H.3
  • 3
    • 0037178205 scopus 로고    scopus 로고
    • Applications of conducting polymers to biosensors
    • A. Chaubey, and B.D. Malhotra Applications of conducting polymers to biosensors Biosens. Bioelectron. 17 2002 441 456
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 441-456
    • Chaubey, A.1    Malhotra, B.D.2
  • 4
    • 0028773330 scopus 로고
    • Amperometric glucose sensors based on immobilised glucose-polyquinone system
    • T. Katu, H.I. Karan, and Y. Okamoto Amperometric glucose sensors based on immobilised glucose-polyquinone system Mediat. Biosens. Anal. Chem. 66 8 1994 1231 1235
    • (1994) Mediat. Biosens. Anal. Chem. , vol.66 , Issue.8 , pp. 1231-1235
    • Katu, T.1    Karan, H.I.2    Okamoto, Y.3
  • 5
    • 0000501477 scopus 로고
    • Amperometric enzyme electrode for maltose based on oligosaccharide dehydrogenase-modified carbon paste electrode containing p-benzoquinone
    • T. Ikeda, T. Shibatta, and M. Senda Amperometric enzyme electrode for maltose based on oligosaccharide dehydrogenase-modified carbon paste electrode containing p-benzoquinone J. Electroanal. Chem. 261 1989 351 362
    • (1989) J. Electroanal. Chem. , vol.261 , pp. 351-362
    • Ikeda, T.1    Shibatta, T.2    Senda, M.3
  • 7
    • 0027179213 scopus 로고
    • Polyferrocenes as mediators in amperometric biosensors for glucose
    • S.P. Hendry, M.F. Cardosi, and A.P.F. Turner Polyferrocenes as mediators in amperometric biosensors for glucose Anal. Chim. Acta 281 1993 453 459
    • (1993) Anal. Chim. Acta , vol.281 , pp. 453-459
    • Hendry, S.P.1    Cardosi, M.F.2    Turner, A.P.F.3
  • 8
    • 11644282828 scopus 로고
    • Effects of trace water on the electrochemistry of zeolite. A-modified electrodes in dimethylformamide
    • E. Katz, N. Itzhak, and I. Wilner Effects of trace water on the electrochemistry of zeolite. A-modified electrodes in dimethylformamide J. Electroanal. Chem. 332 1992 357 363
    • (1992) J. Electroanal. Chem. , vol.332 , pp. 357-363
    • Katz, E.1    Itzhak, N.2    Wilner, I.3
  • 9
    • 0010875420 scopus 로고
    • Electron-transfer kinetics in organised thiol monolayers with attached pentaamine (pyridine) ruthenium redox centers
    • H.O. Finklea, and D.D. Hanshew Electron-transfer kinetics in organised thiol monolayers with attached pentaamine (pyridine) ruthenium redox centers J. Am. Chem. Soc. 114 1992 3173 3181
    • (1992) J. Am. Chem. Soc. , vol.114 , pp. 3173-3181
    • Finklea, H.O.1    Hanshew, D.D.2
  • 10
    • 0041669562 scopus 로고    scopus 로고
    • Evaluation of redox mediators for amperometric biosensors: Ru-complex modified carbon-paste/enzyme electrodes
    • E.V. Ivanova, V.S. Sergeeva, J. Oni, C. Kurzawa, A.D. Ryabov, and W. Schuhmann Evaluation of redox mediators for amperometric biosensors: Ru-complex modified carbon-paste/enzyme electrodes Bioelectrochemistry 60 2003 65 71
    • (2003) Bioelectrochemistry , vol.60 , pp. 65-71
    • Ivanova, E.V.1    Sergeeva, V.S.2    Oni, J.3    Kurzawa, C.4    Ryabov, A.D.5    Schuhmann, W.6
  • 11
    • 0028489808 scopus 로고
    • 'Wired' Enzyme electrodes for amperometric determination of glucose or lactate in the presence of interfering substances
    • T.J. Ohara, R. Rajagopalan, and A. Heller 'Wired' Enzyme electrodes for amperometric determination of glucose or lactate in the presence of interfering substances Anal. Chem. 66 1994 2451 2457
    • (1994) Anal. Chem. , vol.66 , pp. 2451-2457
    • Ohara, T.J.1    Rajagopalan, R.2    Heller, A.3
  • 12
    • 20344405031 scopus 로고
    • Redox polymer films containing enzymes: 2. Glucose oxidase containing enzyme electrodes
    • B.A. Gregg, and A. Heller Redox polymer films containing enzymes: 2. Glucose oxidase containing enzyme electrodes J. Phys. Chem. 95 1991 5970 5975
    • (1991) J. Phys. Chem. , vol.95 , pp. 5970-5975
    • Gregg, B.A.1    Heller, A.2
  • 13
    • 0007518959 scopus 로고
    • Synthesis, characterisation and electron transfer properties of some picolinate complexes of ruthenium
    • N. Ghatak, J. Chakravarty, and N. Bhattacharya Synthesis, characterisation and electron transfer properties of some picolinate complexes of ruthenium Polyhedron 14 23-24 1995 3591 3597
    • (1995) Polyhedron , vol.14 , Issue.23-24 , pp. 3591-3597
    • Ghatak, N.1    Chakravarty, J.2    Bhattacharya, N.3
  • 14
    • 0025955594 scopus 로고
    • Voltammetric determination of electron-transfer rate between an enzyme and a mediator
    • J.F. Rusling, and K. Ito Voltammetric determination of electron-transfer rate between an enzyme and a mediator Anal. Chim. Acta 252 1991 23 27
    • (1991) Anal. Chim. Acta , vol.252 , pp. 23-27
    • Rusling, J.F.1    Ito, K.2
  • 15
    • 0035910239 scopus 로고    scopus 로고
    • Approximate and empirical expression of the steady state catalytic current of mediated bioelectrocatalysis to evaluate enzyme kinetics
    • T. Ohgaru, H. Tatsumi, K. Kano, and T. Ikeda Approximate and empirical expression of the steady state catalytic current of mediated bioelectrocatalysis to evaluate enzyme kinetics J. Electroanal. Chem. 496 2001 37 43
    • (2001) J. Electroanal. Chem. , vol.496 , pp. 37-43
    • Ohgaru, T.1    Tatsumi, H.2    Kano, K.3    Ikeda, T.4
  • 16
    • 0030492775 scopus 로고    scopus 로고
    • Electrochemical evaluation of redox enzyme reaction kinetics based on mediated electrocatalysis in solution
    • K. Kano, T. Ohgaru, H. Nakase, and T. Ikeda Electrochemical evaluation of redox enzyme reaction kinetics based on mediated electrocatalysis in solution Chem. Lett. 1996 439 441
    • (1996) Chem. Lett. , pp. 439-441
    • Kano, K.1    Ohgaru, T.2    Nakase, H.3    Ikeda, T.4
  • 17
    • 0035451537 scopus 로고    scopus 로고
    • Charge transport in solid polymer matrices with redox centres
    • M. Kaneko Charge transport in solid polymer matrices with redox centres Prog. Polym. Sci. 26 2001 1101 1137
    • (2001) Prog. Polym. Sci. , vol.26 , pp. 1101-1137
    • Kaneko, M.1
  • 18
    • 0041152495 scopus 로고
    • Mixed phosphine 2,2′-bipyridine complexes of ruthenium
    • B.P. Sullivan, D.J. Salmon, and T.J. Meyer Mixed phosphine 2,2′-bipyridine complexes of ruthenium Inorg. Chem. 27 1978 3334 3341
    • (1978) Inorg. Chem. , vol.27 , pp. 3334-3341
    • Sullivan, B.P.1    Salmon, D.J.2    Meyer, T.J.3
  • 19
    • 0033673998 scopus 로고    scopus 로고
    • An oxygen-insensitive reagentless glucose biosensor based on osmium-complex modified polypyrrole
    • K. Habermuller, A. Ramanavicius, V. Laurinavicius, and W. Schuhmann An oxygen-insensitive reagentless glucose biosensor based on osmium-complex modified polypyrrole Electroanalysis 12 17 2000 1383 1389
    • (2000) Electroanalysis , vol.12 , Issue.17 , pp. 1383-1389
    • Habermuller, K.1    Ramanavicius, A.2    Laurinavicius, V.3    Schuhmann, W.4
  • 21
    • 0034725543 scopus 로고    scopus 로고
    • Synthesis, X-ray structures, spectroscopic and electrochemical properties of ruthenium(II) complexes containing 2,2′-bipyrimidine
    • Z. Ji, S.D. Huang, and A.R. Guadalupe Synthesis, X-ray structures, spectroscopic and electrochemical properties of ruthenium(II) complexes containing 2,2′-bipyrimidine Inorg. Chim. Acta 305 2000 127 134
    • (2000) Inorg. Chim. Acta , vol.305 , pp. 127-134
    • Ji, Z.1    Huang, S.D.2    Guadalupe, A.R.3
  • 22
    • 0037715477 scopus 로고    scopus 로고
    • Structures, electrochemical and spectroscopic properties of ternary ruthenium(II)-polypyridyl complexes with additional carboxylate biguanide or sulfonamide donors
    • S.M. Couchman, J.M. Dominguez-Vera, J.C. Jeffery, C.A. McKee, S. Nevitt, M. Pohlman, C.M. White, and M.D. Word structures, electrochemical and spectroscopic properties of ternary ruthenium(II)-polypyridyl complexes with additional carboxylate biguanide or sulfonamide donors Polyhedron 17 20 1998 3541 3550
    • (1998) Polyhedron , vol.17 , Issue.20 , pp. 3541-3550
    • Couchman, S.M.1    Dominguez-Vera, J.M.2    Jeffery, J.C.3    McKee, C.A.4    Nevitt, S.5    Pohlman, M.6    White, C.M.7    Word, M.D.8
  • 23
    • 0037186047 scopus 로고    scopus 로고
    • Reagentless mediated biosensors based on polyeletrolyte and sol-gel derived silica matrix
    • J. Niu, and J.Y. Lee Reagentless mediated biosensors based on polyeletrolyte and sol-gel derived silica matrix Sens. Actuators, B 82 2002 250 258
    • (2002) Sens. Actuators, B , vol.82 , pp. 250-258
    • Niu, J.1    Lee, J.Y.2
  • 24
    • 0000282308 scopus 로고
    • Electrochemical study of the rate of activation of the molybdoheme protein sulphate oxidase by organic electron acceptors
    • L.A. Courcy, L. Yang, and R.W. Murray Electrochemical study of the rate of activation of the molybdoheme protein sulphate oxidase by organic electron acceptors Anal. Chem. 65 1993 242 246
    • (1993) Anal. Chem. , vol.65 , pp. 242-246
    • Courcy, L.A.1    Yang, L.2    Murray, R.W.3
  • 26
    • 0000863696 scopus 로고
    • Towards mediator design: Characterisation of tris-(4,4′- substituted-2,2′-bipyridine) complexes of iron(II), ruthenium(II) and osmium(II) as mediators for glucose oxidase of Asperigillus niger and other redox proteins
    • S.M. Zakeeruddin, D.M. Fraser, M.-K. Nazeeruddin, and M. Gratzel Towards mediator design: characterisation of tris-(4,4′-substituted-2,2′- bipyridine) complexes of iron(II), ruthenium(II) and osmium(II) as mediators for glucose oxidase of Asperigillus niger and other redox proteins J. Electroanal. Chem. 337 1992 253 283
    • (1992) J. Electroanal. Chem. , vol.337 , pp. 253-283
    • Zakeeruddin, S.M.1    Fraser, D.M.2    Nazeeruddin, M.-K.3    Gratzel, M.4
  • 27
    • 44049113767 scopus 로고
    • Amperometric processes with glucose oxidase embedded in the electrode
    • S. Sakura, and R.P. Buck Amperometric processes with glucose oxidase embedded in the electrode Bioelectrochem. Bioenerg. 28 1992 387 400
    • (1992) Bioelectrochem. Bioenerg. , vol.28 , pp. 387-400
    • Sakura, S.1    Buck, R.P.2
  • 29
    • 0002984276 scopus 로고
    • Solvent effects on the reactivities of an amperometric glucose sensor
    • E.I. Iwuoha, M.R. Smyth, and M.E.G. Lyons Solvent effects on the reactivities of an amperometric glucose sensor J. Electroanal. Chem. 390 1995 35 45
    • (1995) J. Electroanal. Chem. , vol.390 , pp. 35-45
    • Iwuoha, E.I.1    Smyth, M.R.2    Lyons, M.E.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.