Volumn 30, Issue 10, 2005, Pages 1127-1137

Performance analysis of a compressor driven metal hydride cooling system

Author keywords

Compressor; COP; Irreversibility; Metal hydrides; Second law efficiency

Indexed keywords

COMPRESSORS; HEAT EXCHANGERS; HEATING; HYDRIDES; PERFORMANCE; PRESSURE DROP; REFRIGERATION; THERMODYNAMICS;

EID: 20444443515     PISSN: 03603199     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijhydene.2004.10.014     Document Type: Article
Times cited : (29)

References (16)
  • 2
    • 0021754595 scopus 로고
    • Operating characteristics of a metal hydride heat pump for generating cooled air
    • M. Nagel, Y. Komazaki, M. Uchida, and S. Suda Operating characteristics of a metal hydride heat pump for generating cooled air J Less-Common Met 104 1984 307 314
    • (1984) J Less-Common Met , vol.104 , pp. 307-314
    • Nagel, M.1    Komazaki, Y.2    Uchida, M.3    Suda, S.4
  • 3
    • 0021601869 scopus 로고
    • A hydride heat pump as a bus air conditioner
    • M. Ron A hydride heat pump as a bus air conditioner J Less-Common Met 104 1984 259 278
    • (1984) J Less-Common Met , vol.104 , pp. 259-278
    • Ron, M.1
  • 4
    • 5844338960 scopus 로고
    • Design and fabricate a metallic hydride heat pump with a cooling capacity of 9000 Btu/h
    • Ergenics, Inc., Wyckoff, NJ, USA
    • Golben PM, Huston EL. Design and fabricate a metallic hydride heat pump with a cooling capacity of 9000 Btu/h. Final report no. AD-A213 756, Ergenics, Inc., Wyckoff, NJ, USA 1989.
    • (1989) Final Report No. AD-A213 756 , vol.AD-A213 756
    • Golben, P.M.1    Huston, E.L.2
  • 5
    • 0026219941 scopus 로고
    • Two-stage metal hydride heat transformer laboratory model. Results of reaction test beds
    • R. Werner, and M. Groll Two-stage metal hydride heat transformer laboratory model. Results of reaction test beds J Less-Common Met 172-174 1991 1122 1129
    • (1991) J Less-Common Met , vol.172-174 , pp. 1122-1129
    • Werner, R.1    Groll, M.2
  • 8
    • 20444388097 scopus 로고
    • US Patent no. 4 039 023
    • Maclaine AW. US Patent no. 4 039 023, 1977.
    • (1977)
    • MacLaine, A.W.1
  • 11
    • 0035398239 scopus 로고    scopus 로고
    • The operating characteristics of the compressor driven metal hydride heat pump system
    • J.G. Park, K.J. Jang, P.S. Lee, and J.Y. Lee The operating characteristics of the compressor driven metal hydride heat pump system Int J Hydrogen Energy 26 2001 701 706
    • (2001) Int J Hydrogen Energy , vol.26 , pp. 701-706
    • Park, J.G.1    Jang, K.J.2    Lee, P.S.3    Lee, J.Y.4
  • 12
    • 0036722348 scopus 로고    scopus 로고
    • The development of compressor driven metal hydride heat pump (CDMHHP) system as an air conditioner
    • J.G. Park, S.C. Han, H.Y. Jang, S.M. Lee, P.S. Lee, and J.Y. Lee The development of compressor driven metal hydride heat pump (CDMHHP) system as an air conditioner Int J Hydrogen Energy 27 2002 941 944
    • (2002) Int J Hydrogen Energy , vol.27 , pp. 941-944
    • Park, J.G.1    Han, S.C.2    Jang, H.Y.3    Lee, S.M.4    Lee, P.S.5    Lee, J.Y.6
  • 13
    • 0037172701 scopus 로고    scopus 로고
    • Exergy analysis of the multistage cascade refrigeration cycle used for natural gas liquefaction
    • M. Kanoglu Exergy analysis of the multistage cascade refrigeration cycle used for natural gas liquefaction Int J Energy Res 26 8 2002 763 774
    • (2002) Int J Energy Res , vol.26 , Issue.8 , pp. 763-774
    • Kanoglu, M.1
  • 14
    • 7544229109 scopus 로고    scopus 로고
    • Optimization of the rate of exergy output of a multistage endoreversible combined refrigeration system
    • J. Chen, X. Chen, and C. Wu Optimization of the rate of exergy output of a multistage endoreversible combined refrigeration system Exergy 1 2 2001 100 106
    • (2001) Exergy , vol.1 , Issue.2 , pp. 100-106
    • Chen, J.1    Chen, X.2    Wu, C.3
  • 15
    • 0347494863 scopus 로고    scopus 로고
    • Optimal performance of an irreversible solar assisted heat pump
    • E. Torres-Reyes, and J.C.D. Gortari Optimal performance of an irreversible solar assisted heat pump Exergy 1 2 2001 107 111
    • (2001) Exergy , vol.1 , Issue.2 , pp. 107-111
    • Torres-Reyes, E.1    Gortari, J.C.D.2
  • 16
    • 0018915985 scopus 로고
    • Conservation of energy estimated by second law analysis of power-consuming process
    • W. Leidenfrost, K.H. Lee, and K.H. Korenic Conservation of energy estimated by second law analysis of power-consuming process Energy 5 1980 47 61
    • (1980) Energy , vol.5 , pp. 47-61
    • Leidenfrost, W.1    Lee, K.H.2    Korenic, K.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.