메뉴 건너뛰기




Volumn 32, Issue 3, 2005, Pages 287-297

Multicomponent collection as of 2005

Author keywords

Aggressive multicomponent collection; Apheresis; Autologous erythrocytapheresis; Erythrocythapheresis; Multicomponent apheresis; Multicomponent collection; Red cell apheresis

Indexed keywords

APHERESIS; APPARATUS; BLOOD COMPONENT; BLOOD SAMPLING; BLOOD TRANSFUSION; CELL SUSPENSION; COST CONTROL; DISEASE TRANSMISSION; DIZZINESS; DONOR; ERYTHROCYTAPHERESIS; ERYTHROCYTE; FATIGUE; HEALTH CARE COST; HUMAN; PLASMAPHERESIS; PREOPERATIVE PERIOD; REVIEW; SAFETY; SKIN BRUISING; STOMACH DISEASE; THROMBOCYTOPHERESIS; VIRUS INFECTION;

EID: 20444413424     PISSN: 14730502     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.transci.2005.03.001     Document Type: Article
Times cited : (13)

References (30)
  • 1
    • 0348141707 scopus 로고    scopus 로고
    • Expensive blood safety technologies: Understanding and managing cost and access-to-care issues
    • K.E. Berman Expensive blood safety technologies: Understanding and managing cost and access-to-care issues Transfus Med Rev 18 2004 1 10
    • (2004) Transfus Med Rev , vol.18 , pp. 1-10
    • Berman, K.E.1
  • 2
    • 0023103745 scopus 로고
    • A new technique for hemodilution, preparation of autologous platelet-rich plasma and intraoperative blood salvage in cardiac surgery
    • M. Ferrari, S. Zia, and M Valbonesi A new technique for hemodilution, preparation of autologous platelet-rich plasma and intraoperative blood salvage in cardiac surgery Int J Artif Organs 10 1987 47 50
    • (1987) Int J Artif Organs , vol.10 , pp. 47-50
    • Ferrari, M.1    Zia, S.2    Valbonesi, M.3
  • 3
    • 20444431452 scopus 로고
    • Platelet collection
    • A.A. Pineda M. Valbonesi I.J. Sniecinski Wichtig Milano
    • M. Valbonesi Platelet collection A.A. Pineda M. Valbonesi I.J. Sniecinski Donor hemapheresis 1989 Wichtig Milano 71 76
    • (1989) Donor Hemapheresis , pp. 71-76
    • Valbonesi, M.1
  • 4
    • 0035167453 scopus 로고    scopus 로고
    • Double plateletpheresis (DPA) and tailored RBC collection with the Excel-Pro: Preliminary results
    • M. Valbonesi, and R Bruni Double plateletpheresis (DPA) and tailored RBC collection with the Excel-Pro: Preliminary results Transfus Sci 24 2001 71 73
    • (2001) Transfus Sci , vol.24 , pp. 71-73
    • Valbonesi, M.1    Bruni, R.2
  • 5
    • 0033649039 scopus 로고    scopus 로고
    • Maximizing blood component donations
    • M.J. Fuller Maximizing blood component donations Vox Sang 78 52 2000 47 49
    • (2000) Vox Sang , vol.78 , Issue.52 , pp. 47-49
    • Fuller, M.J.1
  • 6
    • 0026849837 scopus 로고
    • Can (should) apheresis supplant whole blood collection?
    • D. Ciavarella Can (should) apheresis supplant whole blood collection? Transfus Sci 13 1992 201 205
    • (1992) Transfus Sci , vol.13 , pp. 201-205
    • Ciavarella, D.1
  • 7
    • 0032903656 scopus 로고    scopus 로고
    • Dry platelets with the Dideco Excel apparatus
    • M. Valbonesi, and R. Bruni Dry platelets with the Dideco Excel apparatus Transfus Sci 20 1999 101 106
    • (1999) Transfus Sci , vol.20 , pp. 101-106
    • Valbonesi, M.1    Bruni, R.2
  • 8
    • 0006581599 scopus 로고    scopus 로고
    • New options for multi component collection (MCC) with the latest cell separators
    • R. Bruni, and M. Valbonesi New options for multi component collection (MCC) with the latest cell separators Int J Artif Organs 21 5-6 1998 26 30
    • (1998) Int J Artif Organs , vol.21 , Issue.5-6 , pp. 26-30
    • Bruni, R.1    Valbonesi, M.2
  • 9
    • 0346881213 scopus 로고    scopus 로고
    • Improving the bacteriological safety of platelet transfusions
    • M.A. Blajchmann, M. Goldman, and F. Baeza Improving the bacteriological safety of platelet transfusions Transfus Med Rev 18 2004 11 24
    • (2004) Transfus Med Rev , vol.18 , pp. 11-24
    • Blajchmann, M.A.1    Goldman, M.2    Baeza, F.3
  • 10
    • 0035165296 scopus 로고    scopus 로고
    • Cellular contamination of plasma collected with various apheresis systems
    • M. Valbonesi, R. Bruni, and G Florida Cellular contamination of plasma collected with various apheresis systems Transfus Sci 24 2001 91 94
    • (2001) Transfus Sci , vol.24 , pp. 91-94
    • Valbonesi, M.1    Bruni, R.2    Florida, G.3
  • 11
    • 0028606827 scopus 로고
    • Improved red cell quality after erytrhoplasmapheresis with MCS3P
    • G.A. Matthes, U. Tofata, and K. Krause Improved red cell quality after erytrhoplasmapheresis with MCS3P J Clin Apheresis 9 1994 183 188
    • (1994) J Clin Apheresis , vol.9 , pp. 183-188
    • Matthes, G.A.1    Tofata, U.2    Krause, K.3
  • 13
    • 0035164239 scopus 로고    scopus 로고
    • Evaluation of dosed red blood cells units collected with Gambro BCT-Trima
    • M. Valbonesi, R. Bruni, and G. Florio Evaluation of dosed red blood cells units collected with Gambro BCT-Trima Transfus Sci 24 2001 65 70
    • (2001) Transfus Sci , vol.24 , pp. 65-70
    • Valbonesi, M.1    Bruni, R.2    Florio, G.3
  • 14
    • 85059047488 scopus 로고    scopus 로고
    • Hematologic, cellular and biochemical changes in donors giving double-unit red cell concentrate using the Cobe TRIMA automated blood component collection system
    • M. Elfath, S. Sawyer, and P. Withley Hematologic, cellular and biochemical changes in donors giving double-unit red cell concentrate using the Cobe TRIMA automated blood component collection system Transfusion 39 Suppl 1999 19s
    • (1999) Transfusion , vol.39 , Issue.SUPPL.
    • Elfath, M.1    Sawyer, S.2    Withley, P.3
  • 15
    • 0013653091 scopus 로고    scopus 로고
    • Evolving concepts in autologous blood procurement in elective surgery
    • L.T. Goodnough, and T.G. Mark Evolving concepts in autologous blood procurement in elective surgery Am J Med 101 1996 2a 33s
    • (1996) Am J Med , vol.101
    • Goodnough, L.T.1    Mark, T.G.2
  • 16
    • 20444363307 scopus 로고    scopus 로고
    • Evaluation and validation data for Trima red blood cell collection
    • A.D. Dawson, P. Scheerlink, and C. Wood Evaluation and validation data for Trima red blood cell collection Transfusion 2 Suppl 2002
    • (2002) Transfusion , vol.2 , Issue.SUPPL.
    • Dawson, A.D.1    Scheerlink, P.2    Wood, C.3
  • 17
    • 20444419233 scopus 로고    scopus 로고
    • Evaluation of a new instrument for double red cell collection
    • L. Clough, L. Kline, and M. Dabay Evaluation of a new instrument for double red cell collection Transfusion 42 Suppl 2002
    • (2002) Transfusion , vol.42 , Issue.SUPPL.
    • Clough, L.1    Kline, L.2    Dabay, M.3
  • 18
    • 20444420736 scopus 로고    scopus 로고
    • 2RBC collection: A comparision of practices and results at six United Blood Services operatory units
    • M. Hayward 2RBC collection: A comparision of practices and results at six United Blood Services operatory units Transfusion 42 Suppl 2002
    • (2002) Transfusion , vol.42 , Issue.SUPPL.
    • Hayward, M.1
  • 19
    • 0344148323 scopus 로고    scopus 로고
    • Blood donor recruitment to automated red cell collections for fixed site and mobile operations
    • J.F. Dalby Blood donor recruitment to automated red cell collections for fixed site and mobile operations Transfusion 42 Suppl 2002
    • (2002) Transfusion , vol.42 , Issue.SUPPL.
    • Dalby, J.F.1
  • 20
    • 1642464030 scopus 로고    scopus 로고
    • The selection of donors in multicomponent collection management
    • P. Bonomo, G. Garozzo, and F. Bernardello The selection of donors in multicomponent collection management Transfus Apheresis Sci 30 2004 55 59
    • (2004) Transfus Apheresis Sci , vol.30 , pp. 55-59
    • Bonomo, P.1    Garozzo, G.2    Bernardello, F.3
  • 21
    • 20444389988 scopus 로고    scopus 로고
    • Model for improved donor utilization by multiple product collection
    • N.C. Keller, and M.A. Bainbridge Model for improved donor utilization by multiple product collection Transfusion 38 Suppl 7 S J 1998
    • (1998) Transfusion , vol.38 , Issue.7 SUPPL. S J
    • Keller, N.C.1    Bainbridge, M.A.2
  • 22
    • 0344579784 scopus 로고    scopus 로고
    • Safety of donations two units of red blood cells on the Alyx component collection system
    • N. Rugg, T. Greenwalt, and J. Rios Safety of donations two units of red blood cells on the Alyx component collection system Transfusion 42 Suppl 2002
    • (2002) Transfusion , vol.42 , Issue.SUPPL.
    • Rugg, N.1    Greenwalt, T.2    Rios, J.3
  • 23
    • 20444371775 scopus 로고    scopus 로고
    • Donor safety and physiologic response to automated collection of two units of RBC on the Alyx component collection system
    • E. Snyder, L. Baril, and D. Dincecco Donor safety and physiologic response to automated collection of two units of RBC on the Alyx component collection system Vox Sang 83 Suppl 2 2002 234
    • (2002) Vox Sang , vol.83 , Issue.2 SUPPL. , pp. 234
    • Snyder, E.1    Baril, L.2    Dincecco, D.3
  • 24
    • 20444419647 scopus 로고    scopus 로고
    • Evaluation of two unit red cell with Alyx separator
    • F. Schooneman, D. Aguettaz, and N. Delemer Evaluation of two unit red cell with Alyx separator J Clin Apheresis 19 2004 39 [abstract]
    • (2004) J Clin Apheresis , vol.19 , pp. 39
    • Schooneman, F.1    Aguettaz, D.2    Delemer, N.3
  • 25
    • 20444408610 scopus 로고    scopus 로고
    • Aggressive multicomponent collection (MCC) with the Excel-Pro
    • M. Valbonesi, G. Giannini, and P. Carlier Aggressive multicomponent collection (MCC) with the Excel-Pro Vox Sang 83 Suppl 2 2002 234
    • (2002) Vox Sang , vol.83 , Issue.2 SUPPL. , pp. 234
    • Valbonesi, M.1    Giannini, G.2    Carlier, P.3
  • 27
    • 0032938504 scopus 로고    scopus 로고
    • Cost containment in platelet transfusion: Clinical and technical aspects
    • M. Valbonesi, G. Giannini, and R. Bruni Cost containment in platelet transfusion: Clinical and technical aspects Transfus Sci 20 1999 37 42
    • (1999) Transfus Sci , vol.20 , pp. 37-42
    • Valbonesi, M.1    Giannini, G.2    Bruni, R.3
  • 28
    • 0036348614 scopus 로고    scopus 로고
    • Options and cost effectiveness of multi component blood collection
    • G.A. Matthes Options and cost effectiveness of multi component blood collection Transfus Sci 27 2002 115 121
    • (2002) Transfus Sci , vol.27 , pp. 115-121
    • Matthes, G.A.1
  • 29
    • 0028215052 scopus 로고
    • Multicomponent collection (MCS). a new trend in transfusion medicine
    • M. Valbonesi, R. Frisoni, and G. Florio Multicomponent collection (MCS). A new trend in transfusion medicine Int J Artif Organs 17 1994 65 69
    • (1994) Int J Artif Organs , vol.17 , pp. 65-69
    • Valbonesi, M.1    Frisoni, R.2    Florio, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.