-
1
-
-
0028825199
-
Fatigue fracture of the sacral bone associated with septic arthritis of the symphysis pubis
-
A.M. Albertsen, N. Egund, and A.G. Jurik Fatigue fracture of the sacral bone associated with septic arthritis of the symphysis pubis Skeletal Radiol 24 1995 605 607
-
(1995)
Skeletal Radiol
, vol.24
, pp. 605-607
-
-
Albertsen, A.M.1
Egund, N.2
Jurik, A.G.3
-
2
-
-
0014810418
-
A new plate for internal fixation - The dynamic compression plate (DCP)
-
M. Allgower, S. Perren, and P. Matter A new plate for internal fixation - the dynamic compression plate (DCP) Injury 2 1970 40 47
-
(1970)
Injury
, vol.2
, pp. 40-47
-
-
Allgower, M.1
Perren, S.2
Matter, P.3
-
3
-
-
9444220758
-
Outcome after fixation of unstable posterior pelvic ring injuries
-
J.D. Cole, D.A. Blum, and L.J. Ansel Outcome after fixation of unstable posterior pelvic ring injuries Clin Orthop 329 1996 160 179
-
(1996)
Clin Orthop
, vol.329
, pp. 160-179
-
-
Cole, J.D.1
Blum, D.A.2
Ansel, L.J.3
-
4
-
-
0031065996
-
Effect of trauma and pelvic fracture on female genitourinary, sexual, and reproductive function
-
C.E. Copeland, M.J. Bosse, and M.L. McCarthy Effect of trauma and pelvic fracture on female genitourinary, sexual, and reproductive function J Orthop Trauma 11 1997 73 81
-
(1997)
J Orthop Trauma
, vol.11
, pp. 73-81
-
-
Copeland, C.E.1
Bosse, M.J.2
McCarthy, M.L.3
-
5
-
-
0023904752
-
Tension fixation of rupture of the symphysis with woven polydioxanone sutures
-
R. Decker, and W. Ruf Tension fixation of rupture of the symphysis with woven polydioxanone sutures Z Orthop Ihre Grenzgeb 126 1988 14 18
-
(1988)
Z Orthop Ihre Grenzgeb
, vol.126
, pp. 14-18
-
-
Decker, R.1
Ruf, W.2
-
6
-
-
0022824817
-
Pubic osteoarthropathy caused by symphyseal instability or chronic painful symphysiolysis: Treatment by symphysiodesis. Apropos of a case and review of the literature
-
C. Delaunay, F. Roman, and J. Validire Pubic osteoarthropathy caused by symphyseal instability or chronic painful symphysiolysis: treatment by symphysiodesis. Apropos of a case and review of the literature Rev Chir Orthop Reparatrice Appar Mot 72 1986 573 577
-
(1986)
Rev Chir Orthop Reparatrice Appar Mot
, vol.72
, pp. 573-577
-
-
Delaunay, C.1
Roman, F.2
Validire, J.3
-
7
-
-
19244367434
-
Pelvic and acetabular fractures, long term results, retrospective study from Cadolles from 1977 to 1997
-
C.A. Deruaz, P. Tschantz, and Y. Groebli Pelvic and acetabular fractures, long term results, retrospective study from Cadolles from 1977 to 1997 Rev Med Suisse Romande 121 2001 351 355
-
(2001)
Rev Med Suisse Romande
, vol.121
, pp. 351-355
-
-
Deruaz, C.A.1
Tschantz, P.2
Groebli, Y.3
-
8
-
-
0031927466
-
Internal osteosynthesis after unstable pelvic ring fracture in a 3-year-old child
-
A. Gansslen, T. Pohlemann, and T. Hufner Internal osteosynthesis after unstable pelvic ring fracture in a 3-year-old child Unfallchirurg 101 1998 570 573
-
(1998)
Unfallchirurg
, vol.101
, pp. 570-573
-
-
Gansslen, A.1
Pohlemann, T.2
Hufner, T.3
-
9
-
-
0022551725
-
Early open reduction and internal fixation of the disrupted pelvic ring
-
A. Goldstein, T. Phillips, and S.J. Sclafani Early open reduction and internal fixation of the disrupted pelvic ring J Trauma 26 1986 325 333
-
(1986)
J Trauma
, vol.26
, pp. 325-333
-
-
Goldstein, A.1
Phillips, T.2
Sclafani, S.J.3
-
10
-
-
0028809640
-
Functional outcome of patients with unstable pelvic ring fractures stabilized with open reduction and internal fixation
-
G.S. Gruen, M.E. Leit, and R.J. Gruen Functional outcome of patients with unstable pelvic ring fractures stabilized with open reduction and internal fixation J Trauma 39 1995 838 844 discussion 844-5
-
(1995)
J Trauma
, vol.39
, pp. 838-844
-
-
Gruen, G.S.1
Leit, M.E.2
Gruen, R.J.3
-
11
-
-
0027132468
-
A new approach to the internal fixation of unstable pelvic fractures
-
E. Hirvensalo, J. Lindahl, and O. Bostman A new approach to the internal fixation of unstable pelvic fractures Clin Orthop 297 1993 28 32
-
(1993)
Clin Orthop
, vol.297
, pp. 28-32
-
-
Hirvensalo, E.1
Lindahl, J.2
Bostman, O.3
-
13
-
-
0028014292
-
Experience with surgical treatment of ruptures of the symphysis pubis
-
S. Kothe, H.W. Keller, W. Heindel, and K.E. Rehm Experience with surgical treatment of ruptures of the symphysis pubis Zentralbl Chir 119 1994 37 43
-
(1994)
Zentralbl Chir
, vol.119
, pp. 37-43
-
-
Kothe, S.1
Keller, H.W.2
Heindel, W.3
Rehm, K.E.4
-
15
-
-
0022323023
-
Pelvic ring disruptions with symphysis pubis diastasis. Indications, technique, and limitations of anterior internal fixation
-
R.H. Lange, and S.T. Hansen Jr. Pelvic ring disruptions with symphysis pubis diastasis. Indications, technique, and limitations of anterior internal fixation Clin Orthop 201 1985 130 137
-
(1985)
Clin Orthop
, vol.201
, pp. 130-137
-
-
Lange, R.H.1
Hansen Jr., S.T.2
-
16
-
-
0033969297
-
Urologic complications of diastasis of the public symphysis: A trauma case report and review of world literature
-
J. Lee, B.S. Abrahamson, and T.G. Harrington Urologic complications of diastasis of the public symphysis: a trauma case report and review of world literature J Trauma 48 2000 133 136
-
(2000)
J Trauma
, vol.48
, pp. 133-136
-
-
Lee, J.1
Abrahamson, B.S.2
Harrington, T.G.3
-
17
-
-
0025931973
-
Biomechanical testing of new and old fixation devices for vertical shear fractures of the pelvis
-
R.K. Leighton, J.P. Waddell, and T.J. Bray Biomechanical testing of new and old fixation devices for vertical shear fractures of the pelvis J Orthop Trauma 5 1991 313 317
-
(1991)
J Orthop Trauma
, vol.5
, pp. 313-317
-
-
Leighton, R.K.1
Waddell, J.P.2
Bray, T.J.3
-
18
-
-
0014419554
-
Surgical treatment of some pelvic fractures
-
R.L. Leighton Surgical treatment of some pelvic fractures J Am Vet Med Assoc 153 1968 1739 1741
-
(1968)
J Am Vet Med Assoc
, vol.153
, pp. 1739-1741
-
-
Leighton, R.L.1
-
19
-
-
0019838535
-
Surgical fixation of displaced pelvic fractures and dislocations of the symphysis pubis (excluding acetabular fractures)
-
E. Letournel Surgical fixation of displaced pelvic fractures and dislocations of the symphysis pubis (excluding acetabular fractures) Rev Chir Orthop Reparatrice Appar Mot 67 1981 771 782
-
(1981)
Rev Chir Orthop Reparatrice Appar Mot
, vol.67
, pp. 771-782
-
-
Letournel, E.1
-
20
-
-
0017470622
-
Pubic symphysis diastasis treated by open reduction and internal fixation
-
M.M. Lewis, and V. Mayer Pubic symphysis diastasis treated by open reduction and internal fixation Clin Orthop 123 1977 37 39
-
(1977)
Clin Orthop
, vol.123
, pp. 37-39
-
-
Lewis, M.M.1
Mayer, V.2
-
21
-
-
0029788858
-
Indications for anterior fixation of pelvic fractures
-
J.M. Matta Indications for anterior fixation of pelvic fractures Clin Orthop 329 1996 88 96
-
(1996)
Clin Orthop
, vol.329
, pp. 88-96
-
-
Matta, J.M.1
-
22
-
-
0035809902
-
Rupture of the symphysis after spontaneous delivery surgical treatment of four cases
-
C. Mau, J. Ovesen, and J. Jensen Rupture of the symphysis after spontaneous delivery surgical treatment of four cases Ugeskr Laeger 163 2001 1442 1443
-
(2001)
Ugeskr Laeger
, vol.163
, pp. 1442-1443
-
-
Mau, C.1
Ovesen, J.2
Jensen, J.3
-
23
-
-
0015631434
-
Recent disjunctions of the pubic symphysis. Therapeutic indications apropos of 50 cases
-
J. Monfort, J.C. Le Neel, and J. Leborgne Recent disjunctions of the pubic symphysis. Therapeutic indications apropos of 50 cases Ann Chir 27 1973 601 608
-
(1973)
Ann Chir
, vol.27
, pp. 601-608
-
-
Monfort, J.1
Le Neel, J.C.2
Leborgne, J.3
-
25
-
-
0031136876
-
Internal fixation in postpartum symphysis pubis rupture: Report of three cases
-
P.M. Rommens Internal fixation in postpartum symphysis pubis rupture: report of three cases J Orthop Trauma 11 1997 273 276
-
(1997)
J Orthop Trauma
, vol.11
, pp. 273-276
-
-
Rommens, P.M.1
-
26
-
-
0015694099
-
Plate fixation of disrupted symphysis pubis preliminary report
-
I.K. Sharp Plate fixation of disrupted symphysis pubis preliminary report J Bone Joint Surg Br 55 1973 618 620
-
(1973)
J Bone Joint Surg Br
, vol.55
, pp. 618-620
-
-
Sharp, I.K.1
-
27
-
-
0028718722
-
Box plate fixation of the symphysis pubis: Biomechanical evaluation of a new technique
-
P.T. Simonian, M.L. Routt Jr., R.M. Harrington, and A.F. Tencer Box plate fixation of the symphysis pubis: biomechanical evaluation of a new technique J Orthop Trauma 8 1994 483 489
-
(1994)
J Orthop Trauma
, vol.8
, pp. 483-489
-
-
Simonian, P.T.1
Routt Jr., M.L.2
Harrington, R.M.3
Tencer, A.F.4
-
28
-
-
0028694677
-
Internal fixation of the unstable anterior pelvic ring: A biomechanical comparison of standard plating techniques and the retrograde medullary superior pubic ramus screw
-
P.T. Simonian, M.L. Routt Jr., R.M. Harrington, and A.F. Tencer Internal fixation of the unstable anterior pelvic ring: a biomechanical comparison of standard plating techniques and the retrograde medullary superior pubic ramus screw J Orthop Trauma 8 1994 476 482
-
(1994)
J Orthop Trauma
, vol.8
, pp. 476-482
-
-
Simonian, P.T.1
Routt Jr., M.L.2
Harrington, R.M.3
Tencer, A.F.4
-
29
-
-
0029820273
-
Evaluation of new plate designs for symphysis pubis internal fixation
-
P.T. Simonian, J.R. Schwappach, and M.L. Routt Jr. Evaluation of new plate designs for symphysis pubis internal fixation J Trauma 41 1996 498 502
-
(1996)
J Trauma
, vol.41
, pp. 498-502
-
-
Simonian, P.T.1
Schwappach, J.R.2
Routt Jr., M.L.3
-
30
-
-
0026131306
-
Anterior and posterior internal fixation of vertical shear fractures of the pelvis
-
G.W. Stocks, G.T. Gabel, and P.C. Noble Anterior and posterior internal fixation of vertical shear fractures of the pelvis J Orthop Res 9 1991 237 245
-
(1991)
J Orthop Res
, vol.9
, pp. 237-245
-
-
Stocks, G.W.1
Gabel, G.T.2
Noble, P.C.3
-
31
-
-
0025195253
-
Internal fixation of pubic symphysis diastasis with a tension banding technique
-
P.R. Stuart, D. Talbot, and D.D. Milne Internal fixation of pubic symphysis diastasis with a tension banding technique Injury 21 1990 223 224
-
(1990)
Injury
, vol.21
, pp. 223-224
-
-
Stuart, P.R.1
Talbot, D.2
Milne, D.D.3
-
32
-
-
0022620998
-
Separation of the pubic symphysis. An underrecognized peripartum complication
-
R.N. Taylor, and R.D. Sonson Separation of the pubic symphysis. An underrecognized peripartum complication J Reprod Med 31 1986 203 206
-
(1986)
J Reprod Med
, vol.31
, pp. 203-206
-
-
Taylor, R.N.1
Sonson, R.D.2
-
34
-
-
0028812244
-
Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring
-
E. Varga, T. Hearn, J. Powell, and M. Tile Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring Injury 26 1995 75 80
-
(1995)
Injury
, vol.26
, pp. 75-80
-
-
Varga, E.1
Hearn, T.2
Powell, J.3
Tile, M.4
-
35
-
-
0032618654
-
Anterior stabilization in the pubic symphysis separation: A mechanical testing
-
S. Waikakul, K. Soparat, and T. Harnroongroj Anterior stabilization in the pubic symphysis separation: a mechanical testing J Med Assoc Thai 82 1999 72 79
-
(1999)
J Med Assoc Thai
, vol.82
, pp. 72-79
-
-
Waikakul, S.1
Soparat, K.2
Harnroongroj, T.3
-
36
-
-
0023685772
-
Two-hole plate fixation for traumatic symphysis pubis diastasis
-
L.X. Webb, A.G. Gristina, and J.R. Wilson Two-hole plate fixation for traumatic symphysis pubis diastasis J Trauma 28 1988 813 817
-
(1988)
J Trauma
, vol.28
, pp. 813-817
-
-
Webb, L.X.1
Gristina, A.G.2
Wilson, J.R.3
-
37
-
-
0031615285
-
A newer plate system for internal fixation of un-stable pelvic fractures
-
Y. Wen, X. Liu, and B. Ge A newer plate system for internal fixation of un-stable pelvic fractures Int Surg 83 1998 88 90
-
(1998)
Int Surg
, vol.83
, pp. 88-90
-
-
Wen, Y.1
Liu, X.2
Ge, B.3
-
38
-
-
0034130167
-
Osteitis pubis and instability of the pubic symphysis. When nonoperative measures fail
-
P.R. Williams, D.P. Thomas, and E.M. Downes Osteitis pubis and instability of the pubic symphysis. When nonoperative measures fail Am J Sports Med 28 2000 350 355
-
(2000)
Am J Sports Med
, vol.28
, pp. 350-355
-
-
Williams, P.R.1
Thomas, D.P.2
Downes, E.M.3
|