Volumn 86, Issue 5 II, 2005, Pages 586-598

Complications of fluoroscopy-, Ultrasound-, and CT-guided percutaneous interventional procedures;Complications des gestes interventionnels percutanés sous contrôle radioscopique, échographique ou scanographique

Author keywords

Abdomen, hemorrhage; Arthrography; Interventional procedures complications; Liver, biopsy; Lung, biopsy; Lung, hemorrhage; Radiofrequency (RF)ablation

Indexed keywords

BACTERIAL ARTHRITIS; BLEEDING; BLOOD CLOTTING DISORDER; COMPUTER ASSISTED TOMOGRAPHY; ECHOGRAPHY; FLUOROSCOPY; HUMAN; INFECTION; LIVER BIOPSY; LUNG BIOPSY; MALIGNANT NEOPLASTIC DISEASE; MALPRACTICE; MORTALITY; PERCUTANEOUS DRAINAGE; PNEUMOTHORAX; RADIOFREQUENCY ABLATION; REVIEW; RISK FACTOR;

EID: 20444362067     PISSN: 02210363     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0221-0363(05)81412-x     Document Type: Review
Times cited : (16)

References (47)
  • 2
    • 0033041451 scopus 로고    scopus 로고
    • Transthoracic needle aspiration biopsy: Variables that affect risk and pneumothorax
    • Cox JE, Chiles C, McManus CM, Aquino SL, Choplin RH. Transthoracic needle aspiration biopsy: variables that affect risk and pneumothorax. Radiology 1999;212:165-168.
    • (1999) Radiology , vol.212 , pp. 165-168
    • Cox, J.E.1    Chiles, C.2    McManus, C.M.3    Aquino, S.L.4    Choplin, R.H.5
  • 3
    • 0023547116 scopus 로고
    • Postbiopsy pneumothorax: Estimating the risk by chest radiography and pulmonary function tests
    • Fish GD, Stanley JH, Miller KS, Schabel SI, Sutherland SE. Postbiopsy pneumothorax: estimating the risk by chest radiography and pulmonary function tests. AJR 1988;150:71-74.
    • (1988) AJR , vol.150 , pp. 71-74
    • Fish, G.D.1    Stanley, J.H.2    Miller, K.S.3    Schabel, S.I.4    Sutherland, S.E.5
  • 4
    • 0034523283 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: Results with an automated 20-gauge coaxial cutting needle
    • Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol 2000;55:281-287.
    • (2000) Clin Radiol , vol.55 , pp. 281-287
    • Laurent, F.1    Latrabe, V.2    Vergier, B.3    Montaudon, M.4    Vernejoux, J.M.5
  • 5
    • 0035167576 scopus 로고    scopus 로고
    • Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions
    • Yeow KM, See LC, Kui KW, Lin MC, Tsao TC, Ng KF et al. Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions. J Vasc Interv Radiol 2001;12:1305-1312.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 1305-1312
    • Yeow, K.M.1    See, L.C.2    Kui, K.W.3    Lin, M.C.4    Tsao, T.C.5    Ng, K.F.6
  • 6
    • 0032721261 scopus 로고    scopus 로고
    • Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: Incidence risk factors
    • Laurent F, Michel P, Latrabe V, Tunon de Lara M, Marthan R. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence risk factors. AJR Am J Roentgenol 1999;172:1049-1053.
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 1049-1053
    • Laurent, F.1    Michel, P.2    Latrabe, V.3    Tunon De Lara, M.4    Marthan, R.5
  • 7
    • 3142660591 scopus 로고    scopus 로고
    • CT-guided fine-needle aspiration of lung nodules: Effect on outcome of using coaxial technique and immediate cytological evaluation
    • Mullan CP, Kelly BE, Ellis PK, Hughes S, Anderson N, McCluggage. CT-guided fine-needle aspiration of lung nodules: effect on outcome of using coaxial technique and immediate cytological evaluation. Ulster Med J 2004;73:32-36.
    • (2004) Ulster Med J , vol.73 , pp. 32-36
    • Mullan, C.P.1    Kelly, B.E.2    Ellis, P.K.3    Hughes, S.4    Anderson, N.5    McCluggage6
  • 8
    • 0141954905 scopus 로고    scopus 로고
    • CT-guided lung biopsy: Factors influencing diagnostic yield and complication rate
    • Anderson JM, Murchison J, Patel D. CT-guided lung biopsy: factors influencing diagnostic yield and complication rate. Clin Radiol 2003;58:791-797.
    • (2003) Clin Radiol , vol.58 , pp. 791-797
    • Anderson, J.M.1    Murchison, J.2    Patel, D.3
  • 9
    • 0034094967 scopus 로고    scopus 로고
    • Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: Initial results
    • Simon JR, Kalbhen CL, Cooper RA, Flisak ME. Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 2000;215:694-697.
    • (2000) Radiology , vol.215 , pp. 694-697
    • Simon, J.R.1    Kalbhen, C.L.2    Cooper, R.A.3    Flisak, M.E.4
  • 10
    • 0036162011 scopus 로고    scopus 로고
    • Litigation for pneumothorax as a complication of fine-needle aspiration of the breast
    • Bates T, Davidson T, Mansel RE. Litigation for pneumothorax as a complication of fine-needle aspiration of the breast. Br J Surg 2002;89:134-137.
    • (2002) Br J Surg , vol.89 , pp. 134-137
    • Bates, T.1    Davidson, T.2    Mansel, R.E.3
  • 11
    • 0031724775 scopus 로고    scopus 로고
    • Migration of the guide-wire into the pleural cavity after needle localization breast lesions
    • Van Susante JL, Barendregt WB, Bruggink ED. Migration of the guide-wire into the pleural cavity after needle localization breast lesions. Eur J Surg Oncol 1998;24:446-448.
    • (1998) Eur J Surg Oncol , vol.24 , pp. 446-448
    • Van Susante, J.L.1    Barendregt, W.B.2    Bruggink, E.D.3
  • 13
    • 0027043081 scopus 로고
    • Outcome of patients hospitalized for complications after outpatient liver biopsy
    • Janes CH, Lindor KD. Outcome of patients hospitalized for complications after outpatient liver biopsy. Ann Intern Med 1993;118:96-98.
    • (1993) Ann Intern Med , vol.118 , pp. 96-98
    • Janes, C.H.1    Lindor, K.D.2
  • 15
    • 0028913123 scopus 로고
    • Indications, methods, and outcomes of percutaneous liver biopsy in England and Wales: An audit by the British Society of Gastroenterology and the Royal College of Physicians of London
    • Gilmore IT, Burroughs A, Murray-Lyon IM, Williams R, Jenkins D, Hopkins A. Indications, methods, and outcomes of percutaneous liver biopsy in England and Wales: an audit by the British Society of Gastroenterology and the Royal College of Physicians of London. Gut 1995;36:437-441.
    • (1995) Gut , vol.36 , pp. 437-441
    • Gilmore, I.T.1    Burroughs, A.2    Murray-Lyon, I.M.3    Williams, R.4    Jenkins, D.5    Hopkins, A.6
  • 17
    • 0032978585 scopus 로고    scopus 로고
    • Liver resection and needle liver biopsy cause hematogenous dissemination of liver cells
    • Louha M, Nicolet J, Zylberberg H, Sabile A, Vons C, Vona G, et al. Liver resection and needle liver biopsy cause hematogenous dissemination of liver cells. Hepatology 1999;29:879-882.
    • (1999) Hepatology , vol.29 , pp. 879-882
    • Louha, M.1    Nicolet, J.2    Zylberberg, H.3    Sabile, A.4    Vons, C.5    Vona, G.6
  • 18
    • 85039486673 scopus 로고    scopus 로고
    • Does percutaneous liver biopsy of hepatocellular carcinoma cause hematogenous dissemination?
    • Ho Yu SC, Ming Lo DY, Ip CB, Liew CT, Leung TWT, Lau WY. Does percutaneous liver biopsy of hepatocellular carcinoma cause hematogenous dissemination? AJR 2004;183:383-385.
    • (2004) AJR , vol.183 , pp. 383-385
    • Ho Yu, S.C.1    Ming Lo, D.Y.2    Ip, C.B.3    Liew, C.T.4    Leung, T.W.T.5    Lau, W.Y.6
  • 19
  • 20
    • 0037564972 scopus 로고    scopus 로고
    • Complication rate and diagnostic yield of 515 consecutive ultrasound-guided biopsies of renal allografts and native kidney using a 14-gauge Biopty gun
    • Preda A, Van Dijk LC, Van Oostaijen JA, Pattynama PM. Complication rate and diagnostic yield of 515 consecutive ultrasound-guided biopsies of renal allografts and native kidney using a 14-gauge Biopty gun. Eur Radiol 2003;13:527-530.
    • (2003) Eur Radiol , vol.13 , pp. 527-530
    • Preda, A.1    Van Dijk, L.C.2    Van Oostaijen, J.A.3    Pattynama, P.M.4
  • 21
    • 0346103696 scopus 로고    scopus 로고
    • Timing of complications in percutaneous renal biopsy
    • Whittier WL, Korbet SM. Timing of complications in percutaneous renal biopsy. J Am Soc Nephrol 2004;15:142-147.
    • (2004) J Am Soc Nephrol , vol.15 , pp. 142-147
    • Whittier, W.L.1    Korbet, S.M.2
  • 25
  • 26
    • 0035181185 scopus 로고    scopus 로고
    • Patient's assessment of discomfort during MR arthrography of the shoulder
    • Binkert CA, Zanetti M, Hodler J. Patient's assessment of discomfort during MR arthrography of the shoulder. Radiology 2001;221:775-778.
    • (2001) Radiology , vol.221 , pp. 775-778
    • Binkert, C.A.1    Zanetti, M.2    Hodler, J.3
  • 28
    • 0036768262 scopus 로고    scopus 로고
    • Percutaneous drainage of abdominal abcess
    • Men S, Akhan O, Köroglu M. Percutaneous drainage of abdominal abcess. Eur J. Radiol 2002;43:204-218.
    • (2002) Eur J. Radiol , vol.43 , pp. 204-218
    • Men, S.1    Akhan, O.2    Köroglu, M.3
  • 29
    • 0026704196 scopus 로고
    • Percutaneous drainage of 335 consecutive abscesses: Results of primary drainage with 1-year follow-up
    • Lambiase RE, Deyoe L, Cronan JJ, Dorfman GS. Percutaneous drainage of 335 consecutive abscesses: results of primary drainage with 1-year Follow-up. Radiology 1992;184:167-179.
    • (1992) Radiology , vol.184 , pp. 167-179
    • Lambiase, R.E.1    Deyoe, L.2    Cronan, J.J.3    Dorfman, G.S.4
  • 30
    • 0036512882 scopus 로고    scopus 로고
    • Management of visceral interventional radiology catheters: A troubleshooting guide for interventional Radiologists
    • Maher M, Kealey S, McNamara A, O'Laoide R, Gibney RG, Malone D. Management of visceral interventional radiology catheters: A troubleshooting guide for interventional Radiologists. Radiographics 2002;22:305-322.
    • (2002) Radiographics , vol.22 , pp. 305-322
    • Maher, M.1    Kealey, S.2    McNamara, A.3    O'Laoide, R.4    Gibney, R.G.5    Malone, D.6
  • 31
    • 1642568808 scopus 로고    scopus 로고
    • Recurrent abdominal and pelvic abscesses: Incidence, results of repeated percutaneous drainage, and underlying causes in 95 drainages
    • Gervais DA, Ho CH, O'Neill MJ, Arellano RS, Hahn PF, Mueller PR. Recurrent abdominal and pelvic abscesses: incidence, results of repeated percutaneous drainage, and underlying causes in 95 drainages. AJR Am J Roentgenol 2004;182:463-466.
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 463-466
    • Gervais, D.A.1    Ho, C.H.2    O'Neill, M.J.3    Arellano, R.S.4    Hahn, P.F.5    Mueller, P.R.6
  • 32
    • 0742324080 scopus 로고    scopus 로고
    • Major complications after percutaneous nephrostomy-lessons from a department audit
    • Lewis S, Patel U. Major complications after percutaneous nephrostomy-lessons from a department audit. Clin Radiol 2004;59:171-179.
    • (2004) Clin Radiol , vol.59 , pp. 171-179
    • Lewis, S.1    Patel, U.2
  • 33
    • 0028936362 scopus 로고
    • Percutaneous gastrostomy and gastrojejunostomy: Additional experience in 519 procedures
    • Bell SD, Carmody EA, Yeung EY, Thurston WA, Simons ME, Ho CS. Percutaneous gastrostomy and gastrojejunostomy: additional experience in 519 procedures. Radiology 1995;194:817-820.
    • (1995) Radiology , vol.194 , pp. 817-820
    • Bell, S.D.1    Carmody, E.A.2    Yeung, E.Y.3    Thurston, W.A.4    Simons, M.E.5    Ho, C.S.6
  • 34
    • 0032967858 scopus 로고    scopus 로고
    • Percutaneous gastrostomy and gastrostojejunostomy with gastropexy: Experience in 701 procedures
    • Dewald CL, Hiette PO, Sewall LE, Fredenberg PG, Palestrant AM. Percutaneous gastrostomy and gastrostojejunostomy with gastropexy: experience in 701 procedures. Radiology 1999;211:651-656.
    • (1999) Radiology , vol.211 , pp. 651-656
    • Dewald, C.L.1    Hiette, P.O.2    Sewall, L.E.3    Fredenberg, P.G.4    Palestrant, A.M.5
  • 35
    • 0036902565 scopus 로고    scopus 로고
    • Complications of radiofrequency coagulation of liver tumour
    • Mulier S, Mulier P, Ni Y, Miao Y, Dupas B, Marchal G, et al. Complications of radiofrequency coagulation of liver tumour. Br J Surg. 2002;89:1206-1222.
    • (2002) Br J Surg , vol.89 , pp. 1206-1222
    • Mulier, S.1    Mulier, P.2    Ni, Y.3    Miao, Y.4    Dupas, B.5    Marchal, G.6
  • 37
    • 0038192394 scopus 로고    scopus 로고
    • Major complications after radiofrequency thermal-ablation of hepatic tumors: Spectrum of imaging findings
    • Rhim H, Yoon KH, Lee JM, Cho Y, Cho JS, Kim SH, et al. Major complications after radiofrequency thermal-ablation of hepatic tumors: spectrum of imaging findings. Radiographics 2003;23:123-136.
    • (2003) Radiographics , vol.23 , pp. 123-136
    • Rhim, H.1    Yoon, K.H.2    Lee, J.M.3    Cho, Y.4    Cho, J.S.5    Kim, S.H.6
  • 38
    • 12144285907 scopus 로고    scopus 로고
    • Early and late complications after radiofrequency ablation of malignant liver tumors in 608 patients
    • Curley SA, Marra P, Beaty K, Ellis LM, Vauthey JN, Abdalla EK, et al. Early and late complications after radiofrequency ablation of malignant liver tumors in 608 patients. Ann Surg 2004;239:450-458.
    • (2004) Ann Surg , vol.239 , pp. 450-458
    • Curley, S.A.1    Marra, P.2    Beaty, K.3    Ellis, L.M.4    Vauthey, J.N.5    Abdalla, E.K.6
  • 40
    • 2442657934 scopus 로고    scopus 로고
    • Thoracic tumors treated with CT-guided radiofrequency ablation: Initial experience
    • Yasui K, Kanazawa S, Sano Y, Fujiwara T, Kagawa S, Mimura H, et al. Thoracic tumors treated with CT-guided radiofrequency ablation: initial experience. Radiology 2004;231:850-857.
    • (2004) Radiology , vol.231 , pp. 850-857
    • Yasui, K.1    Kanazawa, S.2    Sano, Y.3    Fujiwara, T.4    Kagawa, S.5    Mimura, H.6
  • 41
    • 4344707893 scopus 로고    scopus 로고
    • Percutaneous radiofrequency ablation of lung tumors with expandable needle electrodes: Tips from preliminary experience
    • Steinke K, King J, Glenn DW, Morris DL. Percutaneous radiofrequency ablation of lung tumors with expandable needle electrodes: tips from preliminary experience. AJR 2004;183:605-611.
    • (2004) AJR , vol.183 , pp. 605-611
    • Steinke, K.1    King, J.2    Glenn, D.W.3    Morris, D.L.4
  • 43
    • 0033094567 scopus 로고    scopus 로고
    • Chemoembolization of hepatic neoplasms: Safety, complications, and when to worry
    • Gates J, Hartnell GG, Stuart KE, Clouse ME. Chemoembolization of hepatic neoplasms: safety, complications, and when to worry. Radiographics 1999;19399-20414.
    • (1999) Radiographics , pp. 19399-20414
    • Gates, J.1    Hartnell, G.G.2    Stuart, K.E.3    Clouse, M.E.4
  • 44
    • 0037086539 scopus 로고    scopus 로고
    • A Prospective study regarding the complications of transcatheter intraarterial lipiodol chemoembolization in patients with hepatocellular carcinoma
    • Chan AO, Yuen MF, Hui CK, Tso WK, Lai CL. A Prospective study regarding the complications of transcatheter intraarterial lipiodol chemoembolization in patients with hepatocellular carcinoma. Cancer 2002;94:1747-1752.
    • (2002) Cancer , vol.94 , pp. 1747-1752
    • Chan, A.O.1    Yuen, M.F.2    Hui, C.K.3    Tso, W.K.4    Lai, C.L.5
  • 45
    • 0036085956 scopus 로고    scopus 로고
    • Transarterial chemoembolization for unresectable hepatocellular carcinoma: Meta-analysis of randomised controlled trials
    • Camma C, Schepis F, Orlando A, Albanese M, Shahied L, Trevisani F. Transarterial chemoembolization for unresectable hepatocellular carcinoma: meta-analysis of randomised controlled trials. Radiology 2002;224:47-54.
    • (2002) Radiology , vol.224 , pp. 47-54
    • Camma, C.1    Schepis, F.2    Orlando, A.3    Albanese, M.4    Shahied, L.5    Trevisani, F.6
  • 47
    • 2942750414 scopus 로고    scopus 로고
    • Gérer les risques en imagerie médicale
    • Leclet H. Gérer les risques en imagerie médicale. J Radiol 2004;85:271-272.
    • (2004) J Radiol , vol.85 , pp. 271-272
    • Leclet, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.