-
1
-
-
84977061085
-
Tolerance of early walking with total contact among below-knee amputees - A randomized test
-
Liedberg E, Hommerberg H, Persson BM. Tolerance of early walking with total contact among below-knee amputees - a randomized test. Pros Orth Int 1983;7:91-5.
-
(1983)
Pros Orth Int
, vol.7
, pp. 91-95
-
-
Liedberg, E.1
Hommerberg, H.2
Persson, B.M.3
-
4
-
-
0018893192
-
The management of amputations of the leg using a new rigid foam plaster for prosthetic fitting
-
Hölter W, Echterhoff M, Blömer A, Verfürden H. The management of amputations of the leg using a new rigid foam plaster for prosthetic fitting. Int Orthop 1980;4:73-7.
-
(1980)
Int Orthop
, vol.4
, pp. 73-77
-
-
Hölter, W.1
Echterhoff, M.2
Blömer, A.3
Verfürden, H.4
-
6
-
-
0027064961
-
Lower-extremity amputation with immediate postoperative prosthetic placement
-
Folsom D, King T, Rubin JR. Lower-extremity amputation with immediate postoperative prosthetic placement. Am J Surg 1992;164:320-2.
-
(1992)
Am J Surg
, vol.164
, pp. 320-322
-
-
Folsom, D.1
King, T.2
Rubin, J.R.3
-
7
-
-
0016812710
-
Prosthetic fitting immediately after below-knee amputation
-
Kitowski VJ, Appel MF, Haslam T. Prosthetic fitting immediately after below-knee amputation. South Med J 1975;68:739-42.
-
(1975)
South Med J
, vol.68
, pp. 739-742
-
-
Kitowski, V.J.1
Appel, M.F.2
Haslam, T.3
-
8
-
-
0022617466
-
Early postsurgical prosthetic fitting with a prefabricated plastic limb
-
Kraker D, Pinzur MS, Daley R, Osterman H. Early postsurgical prosthetic fitting with a prefabricated plastic limb. Orthop 1986;9:989-92.
-
(1986)
Orthop
, vol.9
, pp. 989-992
-
-
Kraker, D.1
Pinzur, M.S.2
Daley, R.3
Osterman, H.4
-
9
-
-
0347279901
-
Principles of prosthetic prescription in the early month after lower-limb amputation
-
Murdoch G, Donovan RG, eds. Oxford: Blackwell Scientific Publications
-
Angel JC. Principles of prosthetic prescription in the early month after lower-limb amputation. In: Murdoch G, Donovan RG, eds. Amputation surgery and lower-limb prosthetics. Oxford: Blackwell Scientific Publications, 1988:1,63-70.
-
(1988)
Amputation Surgery and Lower-limb Prosthetics
, pp. 1
-
-
Angel, J.C.1
-
12
-
-
0028064470
-
Prosthetic components in clinical practice
-
Gottschalk FA. Prosthetic components in clinical practice. J Rehab Sci 1994; 7:55-6.
-
(1994)
J Rehab Sci
, vol.7
, pp. 55-56
-
-
Gottschalk, F.A.1
-
14
-
-
0017473662
-
Disabling skin reactions associated with stump edema
-
Levy SW. Disabling skin reactions associated with stump edema. Int J Dermatol 1977;16:122-5.
-
(1977)
Int J Dermatol
, vol.16
, pp. 122-125
-
-
Levy, S.W.1
-
15
-
-
0019432133
-
Comparing the effectiveness of elastic bandages and shrinker socks for lower-extremity amputees
-
Manella KJ. Comparing the effectiveness of elastic bandages and shrinker socks for lower-extremity amputees. Phys Ther 1981;61:334-7.
-
(1981)
Phys Ther
, vol.61
, pp. 334-337
-
-
Manella, K.J.1
-
16
-
-
0028298197
-
The effect of semirigid dressings on below-knee amputations
-
MacLean N, Fick GH. The effect of semirigid dressings on below-knee amputations. Phys Ther 1994;74:668-73.
-
(1994)
Phys Ther
, vol.74
, pp. 668-673
-
-
MacLean, N.1
Fick, G.H.2
-
18
-
-
0019212821
-
Skin problems of the leg amputee
-
Levy SW. Skin problems of the leg amputee. Pros Orth Int 1980;4:37-44.
-
(1980)
Pros Orth Int
, vol.4
, pp. 37-44
-
-
Levy, S.W.1
-
20
-
-
0018068564
-
An instrument for monitoring stump edema and shrinkage in amputees
-
Fernie GR, Holliday PJ, Lobb RJ. An instrument for monitoring stump edema and shrinkage in amputees. Pros Orth Int 1978;2:69-72.
-
(1978)
Pros Orth Int
, vol.2
, pp. 69-72
-
-
Fernie, G.R.1
Holliday, P.J.2
Lobb, R.J.3
-
21
-
-
2042434182
-
-
Göteborg: Department of Orthopaedic Surgery II, Sahlgren's Hospital, University of Göteborg, Thesis
-
Renstrom P, Goldie IF. In: The below-knee amputee. Göteborg: Department of Orthopaedic Surgery II, Sahlgren's Hospital, University of Göteborg, Thesis, 1981.
-
(1981)
The Below-knee Amputee
-
-
Renstrom, P.1
Goldie, I.F.2
-
22
-
-
0023984808
-
Volume changes occurring in postoperative below-knee residual limbs
-
Golbrandson FL, Wirta RW, Kuncir EJ, Lieber RL, Oishi C. Volume changes occurring in postoperative below-knee residual limbs. J Rehab Res Dev 1988; 25:11-8.
-
(1988)
J Rehab Res Dev
, vol.25
, pp. 11-18
-
-
Golbrandson, F.L.1
Wirta, R.W.2
Kuncir, E.J.3
Lieber, R.L.4
Oishi, C.5
-
23
-
-
0020050715
-
Volume fluctuations in the residual limbs of lower-limb amputees
-
Fernie GR, Holliday PJ. Volume fluctuations in the residual limbs of lower-limb amputees. Arch Phys Med Rehab 1982;63:162-5.
-
(1982)
Arch Phys Med Rehab
, vol.63
, pp. 162-165
-
-
Fernie, G.R.1
Holliday, P.J.2
-
24
-
-
84866186345
-
The applications of CAD/CAM technique in prosthetics and orthotics
-
ISSN 1100-2247
-
Lilja M, Öberg T, Karsznia A. The applications of CAD/CAM technique in prosthetics and orthotics. Biomechanics seminar, ISSN 1100-2247, 1993; 7:157-62.
-
(1993)
Biomechanics Seminar
, vol.7
, pp. 157-162
-
-
Lilja, M.1
Öberg, T.2
Karsznia, A.3
-
25
-
-
0021954001
-
Computer-aided design, computer-aided manufacture and other computer aids in prosthetics and orthotics
-
Klasson B. Computer-aided design, computer-aided manufacture and other computer aids in prosthetics and orthotics. Pros Orth Int 1985;9:3-11.
-
(1985)
Pros Orth Int
, vol.9
, pp. 3-11
-
-
Klasson, B.1
-
26
-
-
0344907100
-
CAD/CAM in prothetik und orthetik - Stand der technik.
-
Brussel A. CAD/CAM in prothetik und orthetik - stand der technik. (CAD/CAM in Prosthetics and Orthotics - state of the art). Orthopädie Technik 1991; 7:487-95.
-
(1991)
Orthopädie Technik
, vol.7
, pp. 487-495
-
-
Brussel, A.1
-
28
-
-
0000212133
-
The CAPOD® system - A Scandinavian CAD/CAM system for prosthetic sockets
-
Öberg K, Kofman J, Karlsson A, Lindstrom B, Sigblad G. The CAPOD® system - a Scandinavian CAD/CAM system for prosthetic sockets. JPO 1989;1:139-48.
-
(1989)
JPO
, vol.1
, pp. 139-148
-
-
Öberg, K.1
Kofman, J.2
Karlsson, A.3
Lindstrom, B.4
Sigblad, G.5
-
29
-
-
0027096991
-
A CAD/CAM method for custom below-knee sockets
-
Engsberg JR, Clynch GS, Lee AG, Allan JS, Harder JA. A CAD/CAM method for custom below-knee sockets. Pros Orth Int 1992;16:183-8.
-
(1992)
Pros Orth Int
, vol.16
, pp. 183-188
-
-
Engsberg, J.R.1
Clynch, G.S.2
Lee, A.G.3
Allan, J.S.4
Harder, J.A.5
-
30
-
-
0029043206
-
Volumetric determinations with CAD/CAM in prosthetics and orthotics: Errors of measurement
-
Lilja M, Öberg T. Volumetric determinations with CAD/CAM in prosthetics and orthotics: errors of measurement. J Rehab Res Dev 1995;32:141-8.
-
(1995)
J Rehab Res Dev
, vol.32
, pp. 141-148
-
-
Lilja, M.1
Öberg, T.2
-
32
-
-
0020626542
-
A clinical standard of stump measurement and classification in lower-limb amputees
-
Persson BM, Liedberg E. A clinical standard of stump measurement and classification in lower-limb amputees. Pros Orth Int 1983;7:17-24.
-
(1983)
Pros Orth Int
, vol.7
, pp. 17-24
-
-
Persson, B.M.1
Liedberg, E.2
-
34
-
-
0025739710
-
Lower-limb amputation for vascular insufficiency
-
Ebskov LB. Lower-limb amputation for vascular insufficiency. Int J Rehab Res 1991;14:59-64.
-
(1991)
Int J Rehab Res
, vol.14
, pp. 59-64
-
-
Ebskov, L.B.1
-
35
-
-
0027049159
-
Amputation for occlusive arterial disease. A prospective multicentre study of 177 amputees
-
Eneroth M, Persson BM. Amputation for occlusive arterial disease. A prospective multicentre study of 177 amputees. Int Orthop 1992;16:383-7.
-
(1992)
Int Orthop
, vol.16
, pp. 383-387
-
-
Eneroth, M.1
Persson, B.M.2
-
37
-
-
0015898631
-
Roentgenological study of certain stump-socket relationship in above-knee amputees with special regard to tissue proportions, socket fit and attachment stability
-
Eriksson U, James U. Roentgenological study of certain stump-socket relationship in above-knee amputees with special regard to tissue proportions, socket fit and attachment stability. Upsala J Med Sci 1973;78:203-14.
-
(1973)
Upsala J Med Sci
, vol.78
, pp. 203-214
-
-
Eriksson, U.1
James, U.2
-
38
-
-
0027252937
-
Movement of the tibial end in a PTB prosthesis socket: A sagittal X-ray study of the PTB prosthesis
-
Lilja M, Johansson T, Öberg T. Movement of the tibial end in a PTB prosthesis socket: a sagittal X-ray study of the PTB prosthesis. Pros Orth Int 1993;17:21-6.
-
(1993)
Pros Orth Int
, vol.17
, pp. 21-26
-
-
Lilja, M.1
Johansson, T.2
Öberg, T.3
|