메뉴 건너뛰기




Volumn 65, Issue 2, 2005, Pages 247-253

Two-year follow-up intravascular ultrasound analysis after bare metal stent implantation in 120 lesions

Author keywords

Coronary disease; Stent; Ultrasonics

Indexed keywords

METAL;

EID: 20344394194     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/ccd.20358     Document Type: Article
Times cited : (8)

References (17)
  • 7
    • 0035312809 scopus 로고    scopus 로고
    • American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS): A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    • Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, Pinto FJ, Rosenfield K, Siegel RJ, Tuzcu EM, Yock PG. American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS): a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001;37:1478-1492.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1478-1492
    • Mintz, G.S.1    Nissen, S.E.2    Anderson, W.D.3    Bailey, S.R.4    Erbel, R.5    Fitzgerald, P.J.6    Pinto, F.J.7    Rosenfield, K.8    Siegel, R.J.9    Tuzcu, E.M.10    Yock, P.G.11
  • 12
    • 0032568479 scopus 로고    scopus 로고
    • Remodeling of in-stent neointima, which became thinner and transparent over 3 years: Serial angiographic and angioscopic follow-up
    • Asakura M, Ueda Y, Nanto S, Hirayama A, Adachi T, Kitakaze M, Hori M, Kodama K. Remodeling of in-stent neointima, which became thinner and transparent over 3 years: serial angiographic and angioscopic follow-up. Circulation 1998;97:2003-2006.
    • (1998) Circulation , vol.97 , pp. 2003-2006
    • Asakura, M.1    Ueda, Y.2    Nanto, S.3    Hirayama, A.4    Adachi, T.5    Kitakaze, M.6    Hori, M.7    Kodama, K.8
  • 13
    • 0034090368 scopus 로고    scopus 로고
    • Histopathologic analysis of in-stent neointimal regression in a porcine coronary model
    • Kim WH, Hong MK, Virmani R, Kornowski R, Jones R, Leon MB. Histopathologic analysis of in-stent neointimal regression in a porcine coronary model. Coron Art Dis 2000;11:273-277.
    • (2000) Coron Art Dis , vol.11 , pp. 273-277
    • Kim, W.H.1    Hong, M.K.2    Virmani, R.3    Kornowski, R.4    Jones, R.5    Leon, M.B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.