메뉴 건너뛰기




Volumn 60, Issue 3, 2005, Pages 235-239

Non-touch fittings in hospitals: A procedure to eradicate Pseudomonas aeruginosa contamination

Author keywords

Non touch taps; Pseudomonas aeruginosa; Thermal shock; Water contamination

Indexed keywords

ARTICLE; BACTERIAL STRAIN; BACTERIUM CONTAMINATION; CHLORINATION; CLINICAL ARTICLE; COST EFFECTIVENESS ANALYSIS; DISINFECTION; GENETIC VARIABILITY; GENOTYPE; GRAM NEGATIVE INFECTION; HEAT TREATMENT; HOSPITAL EQUIPMENT; HOSPITAL HYGIENE; HOSPITAL INFECTION; HUMAN; INFECTION CONTROL; NONHUMAN; PSEUDOMONAS AERUGINOSA; SEROTYPING; STRAIN DIFFERENCE; STRAIN IDENTIFICATION; WATER ANALYSIS; WATER SUPPLY;

EID: 20344383485     PISSN: 01956701     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhin.2004.11.023     Document Type: Article
Times cited : (29)

References (11)
  • 1
    • 0035448584 scopus 로고    scopus 로고
    • Mycobacterium xenopi spinal infections after discovertebral surgery: Investigation and screening of a large outbreak
    • P. Astagneau N. Desplaces V. Vincent Mycobacterium xenopi spinal infections after discovertebral surgery: Investigation and screening of a large outbreak Lancet 358 2001 747-751
    • (2001) Lancet , vol.358 , pp. 747-751
    • Astagneau, P.1    Desplaces, N.2    Vincent, V.3
  • 2
    • 0031850166 scopus 로고    scopus 로고
    • Outbreak of nosocomial urinary tract infections due to Pseudomonas aeruginosa in a paediatric surgical unit associated with tap-water contamination
    • A. Ferroni L. Nguyen B. Pron G. Quesne M.C. Brusset P. Berche Outbreak of nosocomial urinary tract infections due to Pseudomonas aeruginosa in a paediatric surgical unit associated with tap-water contamination J Hosp Infect 39 1998 301-307
    • (1998) J. Hosp. Infect. , vol.39 , pp. 301-307
    • Ferroni, A.1    Nguyen, L.2    Pron, B.3    Quesne, G.4    Brusset, M.C.5    Berche, P.6
  • 4
    • 1542510111 scopus 로고    scopus 로고
    • Outbreak of Burkholderia cepacia bacteremia traced to contaminated hospital water used for dilution of an alcohol skin antiseptic
    • R.M. Nasser A.C. Rahi M.F. Haddad Z. Daoud N. Irani-Hakime W.Y. Almawi Outbreak of Burkholderia cepacia bacteremia traced to contaminated hospital water used for dilution of an alcohol skin antiseptic Infect Control Hosp Epidemiol 25 2004 231-239
    • (2004) Infect. Control Hosp. Epidemiol. , vol.25 , pp. 231-239
    • Nasser, R.M.1    Rahi, A.C.2    Haddad, M.F.3    Daoud, Z.4    Irani-Hakime, N.5    Almawi, W.Y.6
  • 5
    • 0027688831 scopus 로고
    • A nosocomial pseudo-outbreak of Mycobacterium xenopi due to a contaminated potable water supply: Lessons in prevention
    • D.H. Sniadack S.M. Ostroff M.A. Karlix A nosocomial pseudo-outbreak of Mycobacterium xenopi due to a contaminated potable water supply: Lessons in prevention Infect Control Hosp Epidemiol 14 1993 636-641
    • (1993) Infect. Control Hosp. Epidemiol. , vol.14 , pp. 636-641
    • Sniadack, D.H.1    Ostroff, S.M.2    Karlix, M.A.3
  • 6
    • 0034773755 scopus 로고    scopus 로고
    • Non-touch fittings in hospitals: A possible source of Pseudomonas aeruginosa and Legionella spp
    • M. Halabi M. Wiesholzer-Pittl J. Schoberl H. Mittermayer Non-touch fittings in hospitals: A possible source of Pseudomonas aeruginosa and Legionella spp J Hosp Infect 49 2001 117-121
    • (2001) J. Hosp. Infect. , vol.49 , pp. 117-121
    • Halabi, M.1    Wiesholzer-Pittl, M.2    Schoberl, J.3    Mittermayer, H.4
  • 7
    • 0347589748 scopus 로고    scopus 로고
    • Non-touch fittings in hospitals: A possible source of Pseudomonas aeruginosa and Legionella spp
    • R. Leprat V. Denizot X. Bertrand D. Talon Non-touch fittings in hospitals: A possible source of Pseudomonas aeruginosa and Legionella spp J Hosp Infect 53 2003 77
    • (2003) J. Hosp. Infect. , vol.53 , pp. 77
    • Leprat, R.1    Denizot, V.2    Bertrand, X.3    Talon, D.4
  • 8
    • 20344375333 scopus 로고    scopus 로고
    • Surveillance microbiologique de l'environnement dans les établissements de santé. Air, eaux et surface
    • Ministère de la Santé, de la Famille et des Personnes Handicapées. Paris: Comité Technique des Infections Nosocomiales
    • Surveillance microbiologique de l'environnement dans les établissements de santé. Air, eaux et surface. Ministère de la Santé, de la Famille et des Personnes Handicapées. Paris: Comité Technique des Infections Nosocomiales; 2002.
    • (2002)
  • 9
    • 20344364516 scopus 로고    scopus 로고
    • CIRCULAIRE DGS/SD7A/SD5C-DHOS/E4 no 2002/243 du 22/04/2002 relative à la prévention du risque lié aux légionelles dans les établissements de santé
    • Paris: Direction Generale de la Santé
    • CIRCULAIRE DGS/SD7A/SD5C-DHOS/E4 no 2002/243 du 22/04/2002 relative à la prévention du risque lié aux légionelles dans les établissements de santé. Paris: Direction Generale de la Santé.
  • 10
    • 0028275082 scopus 로고
    • Lack of association between clinical and environmental isolates of Pseudomonas aeruginosa in hospital wards
    • G.B. Orsi A. Mansi P. Tomao F. Chiarini P. Visca Lack of association between clinical and environmental isolates of Pseudomonas aeruginosa in hospital wards J Hosp Infect 27 1994 49-60
    • (1994) J. Hosp. Infect. , vol.27 , pp. 49-60
    • Orsi, G.B.1    Mansi, A.2    Tomao, P.3    Chiarini, F.4    Visca, P.5
  • 11
    • 0022636494 scopus 로고
    • Detection of Pseudomonas mesophilica as a source of nosocomial infections in a bone marrow transplant unit
    • M.J. Gilchrist J.A. Kraft J.G. Hammond B.L. Connelly M.G. Myers Detection of Pseudomonas mesophilica as a source of nosocomial infections in a bone marrow transplant unit J Clin Microbiol 23 1986 1052-1055
    • (1986) J. Clin. Microbiol. , vol.23 , pp. 1052-1055
    • Gilchrist, M.J.1    Kraft, J.A.2    Hammond, J.G.3    Connelly, B.L.4    Myers, M.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.