메뉴 건너뛰기




Volumn 47, Issue 4, 2005, Pages 175-180

Influence of the material composition of the bone cement on the wear behaviour of cemented total hip stems;Abriebverhalten von zementierten Hüftendoprothesen-Stielen Einfluss der Knochenzement-Zusammensetzung

Author keywords

[No Author keywords available]

Indexed keywords

ABRASIVES; HIP PROSTHESES; IMPLANTS (SURGICAL); SURFACE TOPOGRAPHY; TISSUE; WEAR OF MATERIALS; ZIRCONIUM COMPOUNDS;

EID: 20244380784     PISSN: 00255300     EISSN: None     Source Type: Journal    
DOI: 10.3139/120.100648     Document Type: Review
Times cited : (4)

References (23)
  • 1
    • 0033861254 scopus 로고    scopus 로고
    • Long-term registration has Improved the quality of hip replacement; A review of the Swedish THR Register comparing 160,000 cases
    • Herberts, P.; Malchau, H.: Long-term registration has Improved the quality of hip replacement; A review of the Swedish THR Register comparing 160,000 cases, in: Acta Orthop. Scand. 71 (2000) S. 111
    • (2000) Acta Orthop. Scand. , vol.71 , pp. 111
    • Herberts, P.1    Malchau, H.2
  • 2
    • 0026577202 scopus 로고
    • Metallic debris in femoral endosteolysis in failed cemented total hip arthroplasties
    • Huo, M. H.; Salvati, E. A.; Lieberman, J. R.; Bettis, F.; Bansal, M.: Metallic debris in femoral endosteolysis in failed cemented total hip arthroplasties, in: Clin. Orthop. 276 (1992) S. 157
    • (1992) Clin. Orthop. , vol.276 , pp. 157
    • Huo, M.H.1    Salvati, E.A.2    Lieberman, J.R.3    Bettis, F.4    Bansal, M.5
  • 3
    • 2742521803 scopus 로고
    • Anatomische und hlitopathologische Untersuchungen von Arthroplastikgelenken mit Plexiglasendoprothesen
    • Mittelmeier, H.; Singer, L.: Anatomische und hlitopathologische Untersuchungen von Arthroplastikgelenken mit Plexiglasendoprothesen, in: Arch. Orthop. Unfall-Chir. 48 (1956) S. 519
    • (1956) Arch. Orthop. Unfall-chir. , vol.48 , pp. 519
    • Mittelmeier, H.1    Singer, L.2
  • 6
    • 0030331916 scopus 로고    scopus 로고
    • Tissue reactions to plastic and metallic wear products of joint endoprostheses
    • Willert, H. G.; Semlitsch, M.: Tissue reactions to plastic and metallic wear products of joint endoprostheses, In: Clin. Orthop. 333 (1996) S. 4
    • (1996) Clin. Orthop. , vol.333 , pp. 4
    • Willert, H.G.1    Semlitsch, M.2
  • 7
    • 0033730521 scopus 로고    scopus 로고
    • Frühlockerungen eines zementierten Hüftendoprothesenstiels aus Titan
    • Lichtinger, T. K.; Schürmann, N.; Müller, R. T.: Frühlockerungen eines zementierten Hüftendoprothesenstiels aus Titan, in: Unfallchirurg 103 (2000) S. 956
    • (2000) Unfallchirurg , vol.103 , pp. 956
    • Lichtinger, T.K.1    Schürmann, N.2    Müller, R.T.3
  • 9
    • 0034998508 scopus 로고    scopus 로고
    • Increased loosening of cemented straight stem prostheses made from titanium alloys. An analysis and comparison with prostheses made of cobalt-chromium-nickel alloy
    • Maurer, T. B.; Ochsner, P. E.; Schwarzer, G.; Schumacher, M.: Increased loosening of cemented straight stem prostheses made from titanium alloys. An analysis and comparison with prostheses made of cobalt-chromium-nickel alloy, In: Int. Orthop. 25 (2001) S. 77
    • (2001) Int. Orthop. , vol.25 , pp. 77
    • Maurer, T.B.1    Ochsner, P.E.2    Schwarzer, G.3    Schumacher, M.4
  • 10
    • 0036528664 scopus 로고    scopus 로고
    • Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry
    • Collis, D. K.; Mohler, C. G.: Comparison of clinical outcomes In total hip arthroplasty using rough and polished cemented stems with essentially the same geometry, in: J. Bone Joint Surg. 84-A (2002) S. 586
    • (2002) J. Bone Joint Surg. , vol.84 A , pp. 586
    • Collis, D.K.1    Mohler, C.G.2
  • 11
    • 0031762032 scopus 로고    scopus 로고
    • Effects of design changes on cemented tapered femoral stem fixation
    • Middleton, R. G.; Howie, D. W.; Costi, K.; Sharpe, P.: Effects of design changes on cemented tapered femoral stem fixation, in: Clin. Orthop. 355 (1998) S. 47
    • (1998) Clin. Orthop. , vol.355 , pp. 47
    • Middleton, R.G.1    Howie, D.W.2    Costi, K.3    Sharpe, P.4
  • 12
    • 0033628937 scopus 로고    scopus 로고
    • Biological reactions to wear debris in total Joint replacement
    • Ingham, E.; Fisher, J.: Biological reactions to wear debris in total Joint replacement, in: Proc. Inst. Mech. Eng. [H] 214 (2000) S. 21
    • (2000) Proc. Inst. Mech. Eng. [H] , vol.214 , pp. 21
    • Ingham, E.1    Fisher, J.2
  • 18
    • 0013188942 scopus 로고    scopus 로고
    • Titanium femoral component fixation and experience with a cemented titanium prosthesis
    • I. D. Learmonth (Hg.), Springer, London Berlin Heidelberg
    • Charnley, G.; Judet, T.; Pirou, P.; Garrerau de Louhrese, C.: Titanium femoral component fixation and experience with a cemented titanium prosthesis, in: I. D. Learmonth (Hg.), Intefaces in total hip arthroplasty, Springer, London Berlin Heidelberg (2000) S. 3
    • (2000) Intefaces in Total Hip Arthroplasty , pp. 3
    • Charnley, G.1    Judet, T.2    Pirou, P.3    De Garrerau Louhrese, C.4
  • 20
    • 84860935224 scopus 로고    scopus 로고
    • Oberflächenkontamination nach Kugelstrahlen in der Herstellung von Hüftgelenkimplantaten
    • Schuh, A.; Holzwarth, U.; Kachler, W.; Göske, J.: Oberflächenkontamination nach Kugelstrahlen In der Herstellung von Hüftgelenkimplantaten, in: BIOmaterialien 4 (2003) S. 240
    • (2003) BIOmaterialien , vol.4 , pp. 240
    • Schuh, A.1    Holzwarth, U.2    Kachler, W.3    Göske, J.4
  • 23
    • 0036200705 scopus 로고    scopus 로고
    • Current state of cement fixation in THR
    • Morscher, E. W.; Wirz, D.: Current state of cement fixation in THR. Acta Orthop. Belg. 08 (2002) p. 1.
    • (2002) Acta Orthop. Belg. , vol.8 , pp. 1
    • Morscher, E.W.1    Wirz, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.