Volumn 37, Issue 6, 2005, Pages 591-593

Extraction of entrapped capsules from the small bowel by means of push-and-pull enteroscopy with the double-balloon technique

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL PAIN; ADULT; ARTICLE; CAPSULE ENDOSCOPY; CASE REPORT; COLONOSCOPY; CROHN DISEASE; DEVICE; FOREIGN BODY; GASTROINTESTINAL HEMORRHAGE; HUMAN; INTESTINE OBSTRUCTION; MALE; PRIORITY JOURNAL; SURGICAL APPROACH; SURGICAL TECHNIQUE;

EID: 20144363751     PISSN: 0013726X     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2005-861320     Document Type: Article
Times cited : (70)

References (15)
  • 1
    • 0036350477 scopus 로고    scopus 로고
    • The first prospective controlled trial comparing wireless capsule endoscopy with push enteroscopy in chronic gastrointestinal bleeding
    • Ell C, Remke S, May A et al. The first prospective controlled trial comparing wireless capsule endoscopy with push enteroscopy in chronic gastrointestinal bleeding. Endoscopy 2002; 34: 685-689
    • (2002) Endoscopy , vol.34 , pp. 685-689
    • Ell, C.1    Remke, S.2    May, A.3
  • 2
    • 0242668401 scopus 로고    scopus 로고
    • Wireless capsule video endoscopy is a superior diagnostic tool in comparison to barium follow-through and computerized tomography in patients with suspected Crohn's disease
    • Eliakim R, Fischer D, Suissa A et al. Wireless capsule video endoscopy is a superior diagnostic tool in comparison to barium follow-through and computerized tomography in patients with suspected Crohn's disease. Eur J Gastroenterol Hepatol 2003; 15: 363-367
    • (2003) Eur. J. Gastroenterol. Hepatol. , vol.15 , pp. 363-367
    • Eliakim, R.1    Fischer, D.2    Suissa, A.3
  • 3
    • 20244364772 scopus 로고    scopus 로고
    • Capsule endoscopy in patients with suspected Crohn's disease and negative endoscopy
    • Herrerias JM, Aunedo A, Rodriguez-Téllez M et al. Capsule endoscopy in patients with suspected Crohn's disease and negative endoscopy. Endoscopy 2003; 35: 564-568
    • (2003) Endoscopy , vol.35 , pp. 564-568
    • Herrerias, J.M.1    Aunedo, A.2    Rodriguez-Téllez, M.3
  • 4
    • 4444379249 scopus 로고    scopus 로고
    • Capsule endoscopy in diagnosis of small bowel Crohn's disease
    • Ge ZZ, Hu YB, Xiao SD. Capsule endoscopy in diagnosis of small bowel Crohn's disease. World J Gastroenterol 2004; 10: 1349-1352
    • (2004) World J. Gastroenterol. , vol.10 , pp. 1349-1352
    • Ge, Z.Z.1    Hu, Y.B.2    Xiao, S.D.3
  • 5
    • 4644229586 scopus 로고    scopus 로고
    • Wireless capsule video endoscopy compared to barium follow through and computerized tomography in patients with suspected Crohn's disease: Final report
    • Eliakim R, Suissa A, Yassin K et al. Wireless capsule video endoscopy compared to barium follow through and computerized tomography in patients with suspected Crohn's disease: final report. Dig Liver Dis 2004; 36: 519-522
    • (2004) Dig. Liver Dis. , vol.36 , pp. 519-522
    • Eliakim, R.1    Suissa, A.2    Yassin, K.3
  • 6
    • 9244261580 scopus 로고    scopus 로고
    • Frequency and clinical outcome of capsule retention during capsule endoscopy for GI bleeding of obscure origin
    • Sears DM, Avots-Avotins A, Culp K, Gavin MW. Frequency and clinical outcome of capsule retention during capsule endoscopy for GI bleeding of obscure origin. Gastrointest Endosc 2004; 60: 822-827
    • (2004) Gastrointest. Endosc. , vol.60 , pp. 822-827
    • Sears, D.M.1    Avots-Avotins, A.2    Culp, K.3    Gavin, M.W.4
  • 7
    • 20144385315 scopus 로고    scopus 로고
    • Small bowel obstruction: Indications or contraindications for capsule endoscopy
    • [abstract]
    • Cheifetz AS, Sachar DB, Lewis BS. Small bowel obstruction: indications or contraindications for capsule endoscopy [abstract]. Gastrointest Endosc 2004; 59: 461
    • (2004) Gastrointest. Endosc. , vol.59 , pp. 461
    • Cheifetz, A.S.1    Sachar, D.B.2    Lewis, B.S.3
  • 8
    • 0035127914 scopus 로고    scopus 로고
    • Total enteroscopy with a nonsurgical steerable double-balloon method
    • Yamamoto H, Sekine Y, Sato Y et al. Total enteroscopy with a nonsurgical steerable double-balloon method. Gastrointest Endosc 2001; 53: 216-220
    • (2001) Gastrointest. Endosc. , vol.53 , pp. 216-220
    • Yamamoto, H.1    Sekine, Y.2    Sato, Y.3
  • 9
    • 0344308526 scopus 로고    scopus 로고
    • Double-balloon enteroscopy: Preliminary experience in patients with obscure gastrointestinal bleeding or chronic abdominal pain
    • May A, Nachbar L, Wardak A et al. Double-balloon enteroscopy: preliminary experience in patients with obscure gastrointestinal bleeding or chronic abdominal pain. Endoscopy 2003; 35: 985-991
    • (2003) Endoscopy , vol.35 , pp. 985-991
    • May, A.1    Nachbar, L.2    Wardak, A.3
  • 10
    • 9144261189 scopus 로고    scopus 로고
    • Clinical outcomes of double-balloon endoscopy for the diagnosis and treatment of small-intestinal diseases
    • Yamamoto H, Kita H, Sunada K et al. Clinical outcomes of double-balloon endoscopy for the diagnosis and treatment of small-intestinal diseases. Clin Gastroenterol Hepatol 2004; 2: 1010-1016
    • (2004) Clin. Gastroenterol. Hepatol. , vol.2 , pp. 1010-1016
    • Yamamoto, H.1    Kita, H.2    Sunada, K.3
  • 11
    • 20144373509 scopus 로고    scopus 로고
    • Push-and-pull enteroscopy using the double-balloon technique (double-balloon enteroscopy) of the small bowel: Feasibility, diagnostic and therapeutic yield in patients with suspected small bowel diseases
    • (in press)
    • May A, Nachbar L, Schneider M, Ell C. Push-and-pull enteroscopy using the double-balloon technique (double-balloon enteroscopy) of the small bowel: Feasibility, diagnostic and therapeutic yield in patients with suspected small bowel diseases. Gastrointest Endosc (in press)
    • Gastrointest. Endosc.
    • May, A.1    Nachbar, L.2    Schneider, M.3    Ell, C.4
  • 12
    • 12444251170 scopus 로고    scopus 로고
    • Push-and-pull enteroscopy using the double-balloon technique: Method of assessing depth of insertion and training of the enteroscopy technique using the Erlangen Endo-Trainer
    • May A, Nachbar L, Schneider M et al. Push-and-pull enteroscopy using the double-balloon technique: method of assessing depth of insertion and training of the enteroscopy technique using the Erlangen Endo-Trainer. Endoscopy 2005; 37: 66-70
    • (2005) Endoscopy , vol.37 , pp. 66-70
    • May, A.1    Nachbar, L.2    Schneider, M.3
  • 13
    • 1642267095 scopus 로고    scopus 로고
    • Strictures from Crohn's disease diagnosed by video capsule endoscopy
    • Kastin DA, Buchman AL, Barrett T et al. Strictures from Crohn's disease diagnosed by video capsule endoscopy. J Clin Gastroenterol 2004; 38: 346-349
    • (2004) J. Clin. Gastroenterol. , vol.38 , pp. 346-349
    • Kastin, D.A.1    Buchman, A.L.2    Barrett, T.3
  • 14
    • 4444381953 scopus 로고    scopus 로고
    • Evaluation of the Given patency system in the GI tract: Results of a multi-center study
    • [abstract]
    • Costamagna G, Spada C, Spera G et al. Evaluation of the Given patency system in the GI tract: results of a multi-center study [abstract]. Gastrointest Endosc 2004; 59: M1697
    • (2004) Gastrointest. Endosc. , vol.59
    • Costamagna, G.1    Spada, C.2    Spera, G.3
  • 15
    • 4444236755 scopus 로고    scopus 로고
    • M2A patency capsule prior to video capsule endoscopy in patients with morphological small bowel strictures
    • [abstract]
    • Spada C, Spera G, Riccioni ME et al. M2A patency capsule prior to video capsule endoscopy in patients with morphological small bowel strictures [abstract]. Gastrointest Endosc 2004; 59: M1698
    • (2004) Gastrointest. Endosc. , vol.59
    • Spada, C.1    Spera, G.2    Riccioni, M.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.